922.01Description
Unless otherwise specified, traffic signa l materials and equipment shall be in accordance with the NEMA TS2 2003 Standards Publication and be compatible with the Department’s current inventory of signal equipment.
922.02Traffic Signal Control Equipment
Models shall be selected from the QPL of Traffic Signal and ITS Devices, unless otherwise specified. 10
Each model of controller assembly, CA, and all major units, as defined in NEMA TS2-2.1.1, will be tested and evaluated by the Department’s Traffic Management Division, and approved prior to use. The CA, as defined by NEMA TS2-1.1.7, as being a complete electrical unit, shall include major units operational in a TS2 environment. Major units of the CA are defined as controller unit, CU; malfunction management unit, MMU; bus interface unit, BIU; cabinet power supply; load switches; vehicle detector equipment; cellular modems; radio modems, and flasher. The evaluation of a product will be considered when the De partment receives the preliminary product 20 evaluation submittal form. The Department will advise the manufacturer or vendor of the date of delivery. At the time of de livery, a presentation of the product will be required accompanied by the product broc hure, the operational manual containing procedures for all features incorporated in the CU’s design, and the maintenance manual containing all schematics, pictorial parts layouts, components parts listings, and documented theory of operation.
Certification in accordance with 922.02 (d) shall also accompany the preliminary product evaluation form. If a product has TS2 communicative capabilities, then a data analysis interpretation offered in a decimal form expressing frames by an SDLC 30 protocol analyzer shall accompany the initial documentation as well. When accuracy of documentation is validated, the evaluation period may commence. In addition, all computer system software applicable to a manufacturer’s product shall work with the 922.01
Department’s current operating systems so that upgrades will not be needed to recognize the full potential of the product. Any product under evaluation that has an operational failure occurring during the bench test procedure will be rejected and returned to the submitter.
The product will not be considered for future evaluation without a cover letter documenting failures encountered and changes to the design to correct the failures. A 40 presentation by the manufacturer of the product in question and explanation of why the product failed will be required. Resubmittal of the original product will be expected for testing, evaluation, and approval. Furthermore, two more rejections of a product submitted for evaluation will be cause to deny approval of that model permanently.
The controller model shall be fully NTCIP 1202 compliant and be capable of logging time-stamped controller event data at 100 ms resolution. The events collected shall be logged in the Department specified data file format and shall include, but are not limited to, start and termination of all phase green, amber, and red, pattern changes, and all detector actuations and terminatio ns. Data log file shall be accessible for 50 standard FTP retrieval directly from the controller model’s internal FTP server via the IP addressable RJ-45 Ethernet port.
Continued failures indicative of a trend, repeated random malfunctions, or NEMA non-compliance of a qualified product shall be cause to remove that model from the QPL of Traffic Signal and ITS Devices. If the manufacturer makes any changes to a qualified model of a major unit or controller cabinet terminal/facilities to correct a non-NEMA compliant or safety issue, the Department shall be notified immediately. The manufacturer shall correct all existing equipment purchased by the Department either directly, by contract, or through agreement prior to the change being 60 incorporated at the manufacturer’s production level.
A design change to a qualified model of a CA or any major unit shall require a submittal of documented changes. At the discretion of the Department, resubmission of the model for testing, evaluation, a nd approval may be required. The permanent addition or removal of component parts or wires, printed circuit board modifications, or revisions to memory or processor software, are examples of items that are considered to be design changes.
Contractor A CA, as defined by NEMA TS2-1.1.7, shall be provided by the Contractor and shall be built to the specifications of the intersection design. Each CA shall be supplied with three documentation packets. The documentation shall be provided in both paper hard copy and electronically as specified for each document. Each packet shall consist of:
panels, racks and wiring. The electronic document shall have a minimum of one indexed page for each paper sheet. 80 922.02
manufacturer, model, serial number, software/firmware version as applicable, and inventory number of all major units incorporated in the CA. The electronic document format and the blank worksheet shall be obtained from the Department’s Traffic Management Division.
electronic document format and the blank worksheet shall be obtained from the Department’s Traffic Management Division.
indexed and searchable electronic format file of the instructional programming manual, identical in nature to that approved for use during the evaluation of each product, and a TS2 Type 2 to TS2 Type 1 adapter harness.
All electronic documents shall be submitted to the Asset Manager in the Department’s Traffic Management Division. Each packet shall be labeled with the name of the intersection, the contract num ber, the commission number, and the date of installation. Packet destinations shall be as per 805.08.
A 60-day burn-in period of traffic control equipment shall be required prior to acceptance of the contract. The Contractor shall be responsible for all costs associated with vendor or manufacturer warranty service until acceptance of the contract, or acceptance of that portion of the contract where the traffic c ontrol equipment is installed. 110
The warranty from the manufacturer or vendor shall be provided for the following components: all major units operating in a TS2 environment, light emitting diode, LED, signal indications, load switches, and flashers. Warranty periods shall commence from the date of field placement of the device or on the date of signal turn- on as shown on the IC 636A form, if purchased through a contracting agent.
The following certifications shall be provided. 120
A certification representing each model of approved major unit of a CA shall be on file with the Department. A certification of a production run model for a CU will be valid for a maximum period of five years from the date of approval or unless a significant change is made in the CU. If a significant change is made, a new 922.02
certification shall be submitted. A significant change shall be the addition or deletion of any function or feature in the control unit or any other change as defined in
(a) to the circuitry in the product
A certification shall be provided with each major unit approval request indicating it has been tested and is in accordance with the tests from NEMA TS2-2. The certification shall specify the model and serial number of the product being tested. A complete log of each test shall be provided to the Department and will be maintained by the Department. The log shall indicate any controller component failure during the test, when it failed, and what steps were taken to repair the controller. The log shall include the date of testing, name and title of person conducting the tests, a record of conditions throughout the tests, and a temperature and humidity verses time chart. The maximum report interval of any chart shall be 24 h. The chart shall be from a recording 140 machine used to monitor the status of the environmental chamber during testing.
The following requirements are the minimum for the design and operation of a 16 channel, fully actuated solid state CU. The NEMA TS2 configuration will consist of 2 types of CU’s, Type A1 and Type A2, as defined in NEMA TS2-3.2.
The CU shall be in accordance with NEMA TS2 Standards, all provisions contained herein, and the Department’s specifications. Manufacturer specific enhancements are acceptable. No function or device shall preclude the 150 interchangeability of a CU with another CU of like NEMA specification within a controller assembly.
The CU shall be microprocessor based and both versions shall contain a three- port configuration and shall operate in the NEMA TS2 Type A1 environment.
The CU shall include provisions for time-of-day programming. The CU shall be capable of a minimum of 50 programmed ev ents and be in accordance with NEMA TS2-3.8. 160
A removable nonvolatile EEPROM module or removable serial, flash-based, non- volatile data module shall be utilized in each CU to maintain all programmed data. A real-time clock shall be either battery-backed or powered by a super capacitor and active during a power outage to provide complete time keeping functions and leap year corrections. A switch or other means shall be provided to turn off or disconnect battery power during storage. This shall be acco mplished without physical removal of the battery. Batteries within the CU shall be turned off or disconnected during storage and shipment.
Programming and maintenance manuals fo r approved CU’s shall be identical in nature to that approved for use during the evaluation period of the CU. The Department shall be notified of any changes to the manuals. 922.02
Serial number and model numbers shall be permanently applied on or near the front of circuit boards of the CU and viewable without removing or disconnecting the board. Serial number and model number of the main frame shall be permanently applied externally on top or on the front panel.
The requirements set forth herein refer to a type A1 and A2 CU. Differences between types will be designated.
The CU shall have, as a minimum, the internal diagnostics defined by NEMA TS2-3.9.3.
The CU shall monitor and log the status of events as specified in NEMA TS2- 3.9.3.1.5 in non-volatile memory and shall be selectable via program entry and be retrievable by the system computer via NEMA port 2 or 3. In addition, the CU shall have the ability to log an MMU fault as it occurs. A minimum of 16 entries shall be 190 stored in non-volatile memory. When capacity is exceeded, the oldest entry will be replaced by the newest. Logged entries shall, at a minimum contain the date and time denoted in military style with minute resolution, description of the fault as it would appear on the MMU, and the status of each of the channel inputs at the time the fault occurred, clearly denoting the presence of activity on a channel.
The CU shall be capable of all inputs and outputs listed by controller type in NEMA TS2-3. Pedestrian timing shall be provided on all phases of a CU. The CU
shall be keyboard programmable to enable initialization in any color and phase.
Initialization shall occur after a recognized power interruption, upon MMU reset, or200
upon return from manual or time-of-day flash. The CU shall be programmable from a
closed loop computer system, a laptop computer using the RS232 port, front panel
programming, and by downloading from another like CU through the RS232 port.
Keystroke buttons shall be clearly marked as to function. All programming
buttons and indicators pertinent to the operation of a phase shall be on the front of the
CU and shall have programmable phase omitting and phase skipping capabilities.
The TS2 Type A2 CU shall be in accordance with all applicable requirements for
a Type A2 CU as defined by NEMA TS2-3 and shall contain a full complement of210
connectors.
The CU shall have an RJ-45 ethernet port on the front panel and ethernet module
that provide 10/100 base T interface in half or full duplex and which supports auto-
configuration of the link parameters.
All plug-in modules shall be equipped for easy removal or installation without the
use of tools and shall be readily accessible for maintenance. All internal module plugs
922.02
1169
and edge card plugs shall have the corresponding pin connector position labeled with220
the first and last numbers or the first and last letters.
The enclosure shall be of adequate strength to protect the components during
normal handling. The keypad, liquid crystal display, and all interface connectors
required for the operation and standard field adjustments shall be mounted on the front
panel. Fusing shall be on the front panel of the CU and shall provide protection from
internal or external overload.
The front panel of the controller shall be fastened to the frame such that no special230
tools shall be required to remove or replace printed circuit board modules or to gain
access through the front panel. All hinges shall have stainless steel pins.
The Department’s Traffic Management Division shall be notified each time an
update or revision of the firmware or software is released and be provided with an
explanation of the changes and the benefits of the change. The Department will
determine if and to what extent a revision is to be placed into field operation and may
fully re-evaluate the CU with the revision.
240
Facilities, TF, Requirements
These standards define the minimum requirements for a TS2 Type A1 cabinet,
both inside and out. The performance and construction of the cabinet shall be in
accordance with the applicable requirements of NEMA TS2 sections 4, 5, 6, and 7.
The serial number and model number of the auxiliary equipment shall be permanently
applied externally on or near the front of the product. Programming and maintenance
manuals for approved products shall be identical in nature to that approved for use
during the evaluation period of the product.
250
The Department shall be notified of all changes to the documentation.
Manufacturer specific enhancements are acceptable. No function or device shall
preclude the interchangeability of an auxiliary product with another product of like
NEMA specification within a controller assembly.
The NEMA TS2 Type A1 controller cabinet shall be in accordance with the
following requirements.
The cabinet and the shelves shall be fabricated of aluminum. The cabinet shall be
1/8 in. minimum thickness sheet aluminum or 1/4 in. minimum thickness die-cast
aluminum. The cabinet exterior and interior including shelves shall have a sandblasted,
roughened, or chemically etched finish that reduces gloss, reflection, and glare.
922.02
1170
The main cabinet door shall use a Corbin lock No. 2 and each cabinet shall be
furnished with two No. 2 keys. The lock shall open in a counterclockwise motion only.
The door shall be capable of being opened and stopped in, at least, two ranges of
degree openings as measured from the face of the cabinet door on the hinged side: 80
to 100°, and 170 to 190°. The door shall be hinged on the right side of the cabinet. The270
main door and the police panel door shall close against a weatherproof and dustproof
gasket seal, which shall be permanently bonded to the cabinet. A standard police panel
key shall be provided with each cabinet.
A rain channel shall be incorporated into the design of the main door panel to
prevent liquids from entering the enclosure. A 1 1/2 in. deep drawer shall be provided
in the cabinet, mounted directly beneath the controller support shelf. The drawer shall
have a hinged top cover and shall be capable of accommodating one complete set of
cabinet prints and manuals. This drawer shall support 50 lb in weight when fully
extended. The drawer shall open and close smoothly. Drawer dimensions shall make280
maximum use of available depth offered by the controller shelf and be a minimum of
24 in. wide.
The cabinet shall have a police door and a police control panel within the main
door. The police panel shall have three different switches, one switch for field
indication cutoff, one switch for flashing operation, and one switch for Auto and
Manual with a manual control jack to accept a 1/4 in. monaural phone plug jack. The
switches shall be protected from water when the cabinet door is open.
290
A test switch panel shall be mounted on the inside of the main door. The test
switch panel shall include, as a minimum, the following switches. An auto/flash switch
shall be installed so that when in the flash position, power shall be maintained to the
controller and the intersection shall be placed in flash. A stop time switch shall be
installed so that when in the ‘On’ position the controller shall be stop-timed in the
current interval. A controller equipment power On/Off switch shall be installed which
shall control AC power to the CU, MMU, and cabinet power supply. All switches
mounted on the switch panel on the inside of the main door shall have in place a
mechanism to prevent accidental activation of the switch. “Locking bat” type switches
or side switch guards are acceptable.300
Switch guards, if used, shall be in place for each switch, shall be made of the same
material as the cabinet, and shall enable the operation of the switch without the use of
tools.
All switch functions shall be permanently and clearly labeled. Handwritten
labeling will not be allowed.
The cabinet shall include all required wiring, connectors, and adapters to provide
full compatibility and interchangeability with either a TS2 Type A1 or Type A2310
controller.
922.02
1171
The cabinet shall contain one duplex convenience outlet and a lamp receptacle
that is actuated and turns on when the door is open and goes off when the door is
closed. The cabinet shall also contain an internal On/Off switch to override the lamp
receptacle. The convenience outlet shall be duplex, three-prong, NEMA Type 5-15R
grounding outlet in accordance with NEMA WD - 6, with ground-fault circuit
interruption as defined by the NEC. These units shall be protected with a 15-ampere
cartridge fuse wired ahead of the multi breakers. An additional outlet shall be provided320
in each cabinet and shall be a duplex, three-prong, NEMA Type 5-15R grounding
outlet wired after the cabinet surge protection. This unit shall be protected with a 10-
ampere cartridge fuse. The additional outlet in master cabinets shall be powered by the
10-ampere circuit breaker and through a separate power interrupt switch providing
separate control of the master CU power supply.
The cabinet shall contain a thermostatically controlled ventilating fan and a vent
with a commercially classified uniform 1 in. thick filter. The thermostat shall be
manually adjustable from 90 to 115°F. The fan shall be mounted internally at the top330
and toward the front of the cabinet to exhaust out the front top lip of the cabinet. The
fan shall be rated at a minimum of 100 cu ft per minute as designated by NEMA TS2-
7.9.1The thermostat shall be located within 6 in. of the fan
The filter size shall be in accordance with the provisions for the type of cabinet as
stated in NEMA TS2-7.9.2.3 and shall be a replaceable pleated air filter with a
minimum efficiency reporting value, MERV, rating of 5 or higher as defined by the
ASHRAE 52.2-2007 specification. The cabinet ventilation shall be in accordance with
NEMA TS2-7.9. The diameter of circular openings for cabinet ventilation shall not
exceed 3/8 in. The short dimension for slotted openings shall not exceed 3/8 in.340
Each inductive device, including the fan, shall have a separate power surge
protection.
The cabinet shall contain a jack mounted Type 3 solid state non-repairable flasher
in accordance with NEMA TS2-6.3 electrical and physical dimensions.
The pedestrian load switch and the signal load switch shall be an approved unit
meeting all electrical and physical dimension requirements in accordance with NEMA350
TS2-6. The load switch shall not use a printed circuit board to transmit the 115V AC
line input or signal buss output. Each load switch shall offer three indicators, one for
each circuit indicating the status of the input to the load switch.
The load switch signal outputs shall be brought to a separate terminal strip for
hook-up of the signal displays. Load switches inputs shall be capable of being
programmed for flash, overlap, vehicular, or pedestrian phases with the use of a
922.02
1172
standard slotted or phillips screwdriver via the cabinet terminal strip. The load switch
input programming of the TS2 Type A1 CU shall be accomplished through front panel
data entry of a TS2 Type A1 or a TS2 Type A2 CU.360
The TF layout shall be in accordance with NEMA TS2-5.2.7. The cabinet shall
contain a main TF panel complying with NEMA TS2-5 standards. The model number
of the main panel shall be permanently applied to the front of the panel and shall be
easily readable without removing or disconnecting the panel. Each controller input and
output circuit shall terminate on the main TF panel or on a supplementary panel. The
phase arrangement of the controller shall coincide with the channel arrangement of the370
load switches and MMU. All outputs on channels 9 through 12 field connections shall
KDYHDȝ)FDSDFLWRUSODFHGDWHDFKRXWSXWWHUPLQDORQWKHIURQWRIWKH7)SDQHO$OO
TFs within the cabinet shall be readily accessible for field connection without
removing the controller or associated equipment and for maintenance in the cabinet.
All stranded wiring shall be tinned. A 24 volt relay shall be used on the TF to remove
24V DC from the common side of the load switches, effectively taking the mercury
relay out of the circuit when the signal is put in mechanical flash. The TF panel shall
be hinged at the bottom and capable of swinging down to allow accessibility of the
wiring and terminals at the rear of the panel. The backpanel shall be attached to the
cabinet such that access to the backside of the backpanel, for maintenance purposes,380
shall be accomplished without the use of special tools or removal of auxiliary panels,
shelving, or other cabinet appurtenances. A bracket extending at least half the length
of the NEMA load switch shall support all load switches.
Terminals shall be consecutively numbered on both sides of the TF panel and shall
be in compliance with the appropriate schematic diagrams. All positions for load
switches, flasher, and mechanical relays shall have reference designators on both sides
of the TF panel. All nomenclature shall be on or adjacent to the component or terminal.
All nomenclature shall be machine produced and not handwritten. Cabinet prints shall
identify the function of each terminal position.390
CU and MMU harness cables shall be of sufficient length to allow units to be
placed on either shelf or on top of the cabinet while remaining in operational mode.
RS485 port 1 communications cable shall also be of sufficient length to allow any port
1 cable to be utilized with any TS2 unit within the CA. The RS485 harness shall be
constructed of a high quality shielded communications cable. The TF panel shall
contain a resistor/capacitor network circuit which will provide an external restart pulse
to initiate the startup sequence upon initialization from flash.
Remote flashing shall be provided for all signal circuits. Unless otherwise400
indicated on the plans, phases 2 and 6 shall be wired to flash yellow. All other phases
shall be wired to flash red. Flashing for signal circuits shall be activated on one circuit
for odd numbered phases and on the other circuit for even numbered phases.
922.02
1173
A transparent plexiglass cover shall be provided over the CA power supply panel.
The cover shall leave the switches on the breakers exposed as well as leave access to
terminals at the bottom of the panel for wiring purposes. No terminals on the power
panel shall have silicon protectant on them in lieu of the plexiglass cover. The panel
shall contain a multi-breaker with one 10A circuit breaker to provide overload410
protection to the CU, MMU, BIU, +12/24V DC cabinet power supply, and detection
devices. It shall also contain one main circuit breaker of 35 or 40A, to provide over-
load protection to the signal and flash bus load. All breakers shall have line and load
terminals clearly labeled. The signal bus shall be connected to the incoming AC line
through a mercury contact switch or a solid state control device functionally equivalent
WRWKH1(0$VSHFLILHGFRQWDFWVZLWFK7KHWHUPLQDOVIRU$&DQGíLQSXWWR
the cabinet shall be capable of accepting a No. 6 wire.
With the CA 10A and main 35 or 40A circuit breakers ‘Off’ (tripped), all units
inside the cabinet and the intersection display shall be ‘Off’. With the 10A breaker420
‘On’ and main 35 or 40A circuit breaker ‘Off’, the signal output shall be ‘Off’ and the
major units within the cabinet shall function. With the 10A breaker ‘Off’ and main 35
or 40A circuit breaker ‘On’, the intersection shall be in flash mode and all units within
the cabinet will be ‘Off’.
The cabinet shall contain a 50kA, [ȝVVXUJHVXSSUHVVRU7KHVXUJHVXSSUHVVRU
shall be a 120V AC, 15A, minimum 2-stage parallel/series type device and protect
lines: line-neutral, line-ground and neutral-ground, have a maximum continuous
operating voltage of 140V AC, maximum clamp voltage of 350 volts, and device status
indicators of green/good and red/failed. The device shall plug into a NEMA 12430
position terminal base wired before and in parallel with the 35 or 40A main signal buss
circuit breaker and in series with the 10A circuit breaker for the solid state equipment
and provide for a tool-free replacement of the device. There shall be a minimum of
two electrical receptacles on the equipment side of the device for future auxiliary
equipment. The surge suppressor shall operate between -30 to 165°F. The dimensions
of the unit shall not exceed 4 1/2 in. wide by 7 in. long by 3 1/2 in. deep.
All equipment capable of operating at 12 or 24V DC typically powered by an
individual receptacle type power supply shall have a power cable permanently wired
into the cabinet and the device shall be powered by the cabinet TS2 power supply.440
The cabinet shall contain a MMU and shall be in accordance with the standards
of NEMA TS2- 4. The MMU shall be wired to monitor each load switch output.
All BIU’s shall be in accordance with NEMA TS2 2008, Section 8. Edge mounted
printed circuit boards and rack cards shall not have jumper wire modifications unless
the jumper wires are permanently bonded to the PCB over its entire length. BIU’s shall
922.02
1174
be supplied with each cabinet to allow for maximum phase and function utilization for450
which the cabinet is designed.
All loop amplifier units shall be in accordance with NEMA TS2-6 and shall follow
Type C, two-channel with delay and extend, as stated in NEMA TS2-6.5.2.2.1. All
amplifiers shall be selected from the QPL of Traffic Signal and ITS Devices for each
type of amplifier. In addition, loop amplifiers shall have an LCD display or a RS232
serial data connection and software interface capable of displaying loop status460
including but not limited to operating frequency and -ǻ// GLDJQRVWLFV DQG DOO
amplifier settings and operating parameters. Edge mounted printed circuit boards and
rack cards shall not have jumper wire modifications unless the jumper wires are
permanently bonded to the PCB over its entire length.
All detection components including amplifiers, racks, auxiliary BIU, interface
panels, lead-ins, and all connecting harnesses shall provide one count output channel
per lane of each approach within project limits.
All loop amplifiers designated for counting shall meet all requirements as above470
and shall additionally transmit channel 1 and 2 count pulses on the edge connection
assigned to channels 3 and 4 respectively. Counting amplifiers shall be configured
with count outputs mapped to and recorded in the CU detector logs. The status output
of each active counting channel, 3 and 4, shall be set to logic ground by software
configuration within the amplifier or externally by use of jumper card in the adjacent
slot.
An auxiliary BIU panel may be used strictly for count outputs, channels 3 and 4
only, in this configuration, the status outputs for those count output channels may be
wired to logic ground on the BIU panel. The status outputs for all standard output480
channels shall provide accurate status data at all times. All detector input data to the
CU shall remain accurate at all times.
All M and P-1 cabinets shall incorporate a 16 channel detector rack, configuration
No. 2, in accordance with NEMA TS2-5.3.4, and shall allow operation of a two-
channel detector in each slot and the capability of operation of a two-channel counting
amplifier in each even-numbered slot with the respective count outputs in each odd
numbered slot. The number of detector racks provided shall be determined by the loop
tagging table. All G cabinets shall incorporate an eight-channel detector rack,
configuration No. 1, in accordance with NEMA TS2-5.3.4.490
All detector loop panels and detector racks shall be labeled according to the loop
tagging table and as follows.
922.02
1175
All detection shall be labeled in such a way that the numbering for any loop is
consistent throughout the cabinet; the loop terminated as Loop or Detector 17 shall be
Detector Channel 17 in the detector rack and Detector Input 17 to the controller.
Each loop lead-in panel shall be labeled on the upper left corner with the loop500
numbers that are terminated on that panel as follows: (1-16), (17-32), (33-48), (49-64).
Each loop termination point shall be labeled with the corresponding loop number.
Example: For panel 17-32: loops terminated on this panel will start with 17 and end
with 32.
Each detector rack shall be labeled at the bottom of the rack with a continuous
label. The label shall be 1 in. wide, thermal printed black on clear, white, or matte
polyester tape with permanent adhesive, water, chemical and scratch resistant printed
with 4 lines of Arial, size 10 font. Below the BIU shall be the BIU number and detector510
channel numbers that are contained within the rack as follows: (1-16), (17-32), (33-
48), (49-64). This area shall also contain the intersection for diamond interchanges
controlled from one cabinet.
Each slot shall be labeled below the module with the corresponding loop tag
information. The count output number portion of the information shall be under the
first part of the tag information. For each two-channel module, the label for channel 2
shall be below the label for channel 1.
The TS2 cabinet power supply shall adhere to the guidelines of NEMA TS2-5.3.5.
The power supply shall be encased on all sides so that no circuitry is exposed to the
user.
The G cabinet shall be pedestal-mounted or pole-mounted. As per NEMA TS2-
5.3, the TS2 Type 1 G cabinet, at minimum, shall house an eight-load switch bay
(configuration 2) terminal and facilities panel and shall have 1 adjustable shelf located530
12 in. below the top of the cabinet. The bottom of the cabinet shall be reinforced to
ensure a secure pedestal mounting. The G cabinet shall have dimensions of 25 in. wide,
38 in. high, 18 in. deep with a tolerance of + 4 in. in any or all dimensions.
A cabinet slipfitter shall be used to attach the cabinet to the pedestal. The slipfitter
shall fit a 4 1/2 in. outside diameter pipe and shall have a minimum of three set screws
equally spaced around the slipfitter.
A vent of adequate size shall be provided. The size of the vent and the filter
requirements shall be in accordance with the manufacturer’s recommendations.540
922.02
1176
As per NEMA TS2-5.3, the TS2 Type 1 M cabinet, at minimum, shall house an
eight-load switch bay (configuration 2) terminal and facilities panel and shall have two
adjustable shelves with the first shelf located 15 in. below the top of the cabinet and
the second located 7 in. below the first shelf.
The M cabinet shall be ground-mounted on a concrete foundation at locations and
dimensions as shown on the plans.
550
The M cabinet shall have dimensions of 30 in. wide, 48 in. high, and 16 in. deep
with a tolerance of ±2 in. in any or all dimensions.
Anchor bolts shall be steel in accordance with ASTM A36. Diameter of the bolt
shall be 1/2 in. or 5/8 in. and the minimum length shall be 15 in. plus 3 in. right angle
hook on the unthreaded end.
The top 6 in. of the bolt shall be threaded with 13 NC threads on 1/2 in. bolts and
11 NC threads on 5/8 in. bolts. The hexagon nut, the flat washer, and the threaded end
of the bolt shall be hot-dip galvanized in accordance with ASTM A153 or be560
mechanically galvanized and in accordance with the coating thickness, adherence, and
quality requirements of ASTM B695, class 55.
The cabinet shall include one loop detector rack.
The P-1 cabinet shall be ground mounted on a concrete foundation at locations
and dimensions as shown on the plans with anchor bolts in accordance with
(g)2. As per NEMA TS2-5.3, the TS2 Type 1 P-1 cabinet, at minimum, shall
house a 16-load switch bay (configuration 3) terminal and facilities panel and shall570
have two adjustable shelves with the first shelf a minimum of 30 in. above the bottom
of the cabinet, the second shelf having a minimum clear opening of 11 in. above the
first shelf.
The cabinet shall be 44 in. wide, 52 in. high, and 24 in. deep with a tolerance of
±3 in. in any or all dimensions.
The cabinet shall include two loop detector racks.
The R cabinet shall be ground mounted on a concrete foundation at locations and
dimensions as shown on the plans with anchor bolts in accordance with 922.02(g)2.
As per NEMA TS2-5.3, the TS2 Type 1 R cabinet, at minimum, shall house a 16-load
switch bay (configuration 3) terminal and facilities panel and shall have three
adjustable shelves with the first shelf located a minimum of 30 in. above the bottom
of the cabinet, the second shelf having a minimum clear opening of 11 in. above the
922.02
1177
first shelf and the third shelf having a minimum clear opening of 11 in. above the
second shelf.
The cabinet shall be 44 in. wide, 72 in. high, and 24 in. deep with a tolerance of590
±3 in. in any or all dimensions.
The cabinet shall include three loop detector racks.
Two circuit alternating flasher shall be solid state.
The solid state flasher shall periodically interrupt a source of alternating current
line power. Solid state shall mean electrical circuits, the active components of which600
are semi-conductors, to the exclusion of electromechanical devices or tubes.
The flasher shall be a Type 3 solid state flasher conforming to NEMA TS1-1989.
The flasher output circuit carrying the signal load shall consist of opto or photo isolated
solid state power relays and shall be hard wired to the flasher connector.
Three schematic diagrams and three descriptive parts lists shall be furnished with
each flasher.
Two circuit flashers shall be plug-in design. The flasher design shall not allow the610
unit to be inserted improperly into the plug-in base. The flasher shall have heavy-duty
plugs and jacks capable of handling the rated load current. The rate of flash shall be
50 to 60 flashes per minute.
The flasher shall operate between 95V and 135V AC 60 Hz. No degradation of
performance shall be experienced in environmental changes from -20 to 165°F and 0
to 90% relative humidity.
The cabinet shall be weatherproof and fabricated from cast aluminum or620
aluminum sheeting with a minimum thickness of 1/8 in. The cabinet door shall be the
entire front of the cabinet and shall be hinged on the right or left side of the cabinet. A
Corbin No. 2 lock and two No. 2 keys shall be furnished. The lock shall be located
near the center of the door on the side opposite the hinge.
Minimum dimensions for the cabinet shall be 12 in. deep, 12 in. wide, and 12 in.
high. The maximum dimensions shall be 18 in. deep, 15 in. wide, and 18 in. high.
The cabinet shall have two pole plates for stainless steel band mounting of the
cabinet on a pole with a minimum diameter of 4 in. and a maximum diameter of 18 in.630
Two blank cover plates shall be provided. Two hub plates for 1 in. diameter conduit
shall be provided with gaskets, eight bolts at four bolts per plate, nuts, and washers for
922.02
1178
attaching the hub plates to the cabinet. The cabinet shall be drilled for the mounting of
the pole plates or hub plates as shown on the plans.
It shall have a screened vent in the bottom with a minimum size of 1 3/4 sq in.,
and a minimum of one louvered and screened vent towards the top of the cabinet.
The panel in the cabinet shall be capable of being removed and reinstalled with
simple hand tools. A 25 ampere radio interference filter and surge arrestor wired ahead640
of a 15 ampere circuit breaker shall be mounted on the panel. A terminal block capable
of the following electrical connections shall be mounted on the panel:
Circuit 1 - for connection of field signals (flash circuit 1)
Circuit 2 - for connection of field signals (flash circuit 2)
Circuit 3 - for connection of field signals (field neutral)
AC plus - capable of accepting a No. 6 wire
AC minus - capable of accepting a No. 6 wire
Ground lug - capable of accepting a No. 6 wire.
650
922.03Signal Head Components
The components shall be in accordance with the Institute of Transportation
Engineers for Adjustable Face Vehicular Traffic Control Signal Heads. All new traffic
signal and flasher installations that include new indications shall be fitted with LED
modules. All LED indications shall be selected from the QPL of Traffic Signal and
ITS Devices.
The signal faces shall be sectional in construction, requiring one section for each
lens and furnished in the nominal size of 12 in. Each section of a face shall have a660
rectangular silhouette when viewed from the front or the rear.
The top and bottom of each housing shall have an integral locking ring with 72
serrations to enable rotation of the signal housing in 5° increments. Hub openings in
the top and bottom of the signal housing shall accommodate standard 1 1/2 in. bracket
arms. The thickness of the hub at the top and bottom of the housing shall be a
maximum of 1 in. and a minimum of 3/8 in. The 12 in. door shall have two simple
locking devices. The door on the hinged side shall be attached with hinge pins. Each
lens shall have the standard cap type visor. All screws, latching bolts, locking devices,670
and hinge pins shall be stainless steel.
All LED indications shall be selected from the QPL of Traffic Signal and ITS
Devices.
922.03
1179
All LED indications shall have a permanent indelible sticker affixed to the back
of the module indicating month and year of initial installation.680
All LED indications provided shall be individually listed on a parts list indicating
the contract number, vendor, category, manufacturer, model, serial number, and
inventory number. Hard copy and electronic copies shall be provided. The electronic
document format and the blank worksheet shall be obtained from the Department’s
Traffic Management Division.
All new traffic signal and flasher installations that include new indications shall
be fitted with LED’s. The minimum design requirements for replacement incandescent690
light bulbs used in a traffic signal face shall be in accordance with the Institute of
Transportation Engineers standard for traffic signal bulbs.
The field wiring leads shall be terminated with screw spade lug type connectors.
The LED module wiring leads shall be terminated with 1/4 in. female type connectors
for ease of connection to the terminal block.
Any method to connect two or more sections together may be used, if the700
following requirements are met:
structural integrity when loaded in accordance with Institute of
Transportation Engineers Standards.
1/2 in. cables.
shall be 4 in.
Nuts, bolts, and lock washers shall be hot-dip galvanized in accordance with
ASTM A153 or be mechanically galvanized and be in accordance with the coating
thickness, adherence, and quality requirements of ASTM B695, class 55.
The center section of the three-section signal head, both center sections of the
four-section head, one section of the two-section signal head, and each one-section
signal head shall be equipped with a five-position terminal block for termination of720
field wiring. Each section shall have provisions for two five-position terminal blocks.
Each terminal screw shall have a 1/4 in. corresponding spade tab. The terminal block
shall have a minimum spacing between screw connections of 1/2 in. The height of the
922.03
1180
insulating ridge between screw connections shall be a minimum of 19/32 in. from the
base of the terminal blocks.
The housing, door, and visor of the section shall be made of ultraviolet and heat730
stabilized polycarbonate. The black color shall be permanently molded into the
components.
The housing, door, and visor of the section shall be made of a die-cast, corrosion
resistant, copper free, non-ferrous metal which shall be in accordance with
ASTM B85. All surfaces of the housing, doors, and visor shall be shop painted or
powder coated. The finish shall be nonreflecting flat black, color No. 37038, in
accordance with SAE-AMS-STD-595.
740
The traffic signal backplate shall be one piece and made of sheet aluminum. The
sheet aluminum shall have a nominal thickness of 0.063 in. and shall be according to
ASTM B209, alloy 5052. The backplate shall be designed to be attached to a signal
face without interfering with the opening and closing of the traffic signal door. It shall
be rectangular in shape with round corners and shall be of such dimensions as to give
an exposed margin of 5 in. on each side.
The backplate shall have a 2 in. wide yellow retroreflective strip applied to the
outside perimeter of the backplate. The sheeting shall be Type IV in accordance with750
919.01(b) and applied in the orientation for the maximum angularity according to the
manufacturer’s recommendations.
The aluminum backplates shall be shop painted or powder coated. The finish shall
be nonreflecting flat black, color No. 37038, in accordance with SAE-AMS-STD-595.
A material certification shall accompany each order certifying that a signal head
from a normal production run within the past 12 months, passed the Institute of
Transportation Engineers criteria for breaking strength and deflection. Deflection760
testing is not required in the certification for polycarbonate signal heads.
922.04Pedestrian Signal Components
A pedestrian signal shall be one section and rectangular in shape. The dimensions
of each side may vary from 18 to 19 in., including the visor and the hinges. The signal
shall contain two figures with two different colored messages. The first figure shall
transmit an upraised hand symbol message, and the second figure shall transmit a
922.04
1181
walking person symbol message. All new installations including new pedestrian770
indications shall use Light Emitting Diodes with countdown displays. All pedestrian
LED indications shall be selected from the QPL of Traffic Signal and ITS Devices.
The pedestrian signal shall be in accordance with the standard of the Institute of
Transportation Engineers for Pedestrian Traffic Control Signal Indications.
The housing shall be equipped with mounting device hardware, such as a
clamshell, with round openings at the top and bottom for mounting with brackets made
of iron pipe standard, to fit the 1 1/2 in. pipe. The round openings shall have a common
vertical centerline through the housing to allow for rotation. The round openings shall780
have a serrated ring, with 72 serrations, which enables locking of the housing in 5°
increments. The brackets or the clamshell shall serve as the electrical conduit for the
pedestrian signal. The housing shall be black and made of die-cast, corrosion resistant,
copper free, non-ferrous metal which shall be in accordance with ASTM B85.
The door on the front of the housing may be hinged from any side. The door shall
be gasketed to maintain a weather-tight enclosure when secured to the housing. The
door and the visor shall be made of the same material as the housing or of
polycarbonate. All materials shall be clean, smooth, and free from flaws, cracks,
blowholes, or other imperfections.790
The polycarbonate components shall be black in color. The metal components
shall be painted or powder coated. The finish shall be nonreflecting flat black, color
No. 37038, in accordance with SAE-AMS-STD-595.
The upraised hand and walking person symbols shall each be a minimum of 11
in. in height. The width of the upraised hand symbol shall be a minimum of 7 in. The
width of the walking person symbol shall be a minimum of 6 in. Message
configuration, color, and size shall be in accordance with the standard of the Institute800
of Traffic Engineers for Pedestrian Traffic Control Signal Indications.
Each pedestrian signal shall be completely wired internally and ready for
connection of the field wiring. A suitable terminal block for connection of the internal
wiring and the incoming field wires to the pedestrian signal head shall be provided in
the signal housing.
The light source shall be designed and constructed so that if an electrical or
mechanical failure occurs, the upraised hand and walking person symbols shall also
remain dark.810
Pedestrian push-button assemblies shall meet the standards of the MUTCD and
Americans with Disabilities Act, ADA. Pedestrian push-button assemblies shall be
vandal and weather resistant, be pressure activated with minimal movement, and
922.04
1182
cannot be stuck in a closed or constant call position. A red latching LED and audible
tone shall be provided for confirmation of an actuation call.
A Type D certification in accordance with 916 shall be provided for the pedestrian
push-button. Such certification shall contain the contract number, manufacturer's820
name, model name, supplier's name, location or intersection name, and for a Type APS
pedestrian push button, the sound level measurement of the audible features of the
device.
The pedestrian push-button housing shall be constructed of cast aluminum, cast
zinc alloy, or stainless steel and powder coated yellow, and furnished with suitable
mounting hardware.
The normal state of the LED shall be off. When the push button is pressure
activated, the LED shall be lighted and remain on until the beginning of the walk
phase. The latching relay shall be mounted in the signal cabinet, controlling two
pedestrian phases.
The actuator shall be stainless steel or aluminum with a minimum diameter of 2
in. and a solid state electronic Piezo switch rated for a minimum of 20 million cycles
with no moving plunger or moving electrical contacts. The operating voltage shall be
12-24V. The actuator’s nominal operating force shall not exceed 5 lb.840
The pedestrian sign shall be the R10-3e in accordance with the MUTCD, unless
a different MUTCD sign code is indicated on the plans. The sign base shall be sheet
aluminum in accordance with 919.01(b).
When an APS is specified, the push-button shall have audible and tactile features.
The push-button shall activate both the Walk interval and the APS. The color of the
actuator shall contrast visually with the housing or mounting. A standard850
manufacturer’s warranty shall be provided.
The pedestrian push-button assembly shall include an audible indication of the
Walk interval by either tone or voice and shall be audible from the near side of the
associated crosswalk. If the tone for the Walk interval is the same as the locator tone
of the push-button, it shall have a faster repetition rate than the associated locator tone.
The volume of the audible features shall have automatic volume adjustment based on
the ambient noise levels. Audible features shall be at least 2 dB but no more than 5 dB
louder than ambient sound, up to a maximum volume of 89 dB measured at 36 in. from860
922.04
1183
the device. Audible features may be integral to the pedestrian push-button assembly
or through a separate speaker housing.
When push buttons are separated by 10 ft or more, the audible indication shall be
a tone.
When push buttons are separated by less than 10 ft, the indication shall be a voice
message. When voice messages are used, they shall include a clear message that the
walk interval is in effect and shall indicate to which crossing it applies.
870
The pedestrian push button shall have an audible locator tone feature. The locator
tone shall have a duration of 0.15 seconds or less and shall repeat at 1 second intervals.
The push button assembly shall incorporate a raised arrow. The arrow shall be
raised 0.03125 in. minimum and shall be 1.5 in. minimum in length. The arrow color
shall contrast with the background. The raised arrow shall vibrate to indicate that the
walk interval is in effect.
922.05Blank880
922.06Disconnect Hanger Junction Box
Traffic signal disconnect hanger junction boxes shall consist of a span hanger, a
balance adjuster, a disconnect hanger clevis, and a housing with a hinged door with a
positive latching device. The span hanger, balance adjuster, and all related hardware
shall be hot-dip galvanized in accordance with ASTM A153 or be mechanically
galvanized and conform to the coating thickness, adherence, and quality requirements
of ASTM B695, class 55. The housing shall be made of a die-cast, corrosion resistant,
copper free, non-ferrous metal which shall be in accordance with ASTM B85. The
balance adjuster fitting shall be made of ferrous or non-ferrous metal. When made of890
ferrous metal it shall be galvanized in accordance with the requirements for the
components and related hardware as set out above.
The disconnect hanger shall be designed so the maximum allowable space or play
between the span hanger and the eye-bolt of the balance adjuster and between the
balance adjuster and the disconnect hanger clevis, at points where they are attached to
each other by rivet pins or hex head bolts and nuts with lock washers, shall be 0.062
in. The span hanger bolt where the eye-bolt or the balance adjuster is attached shall be
5/8 in. diameter.
900
When serrated locking rings are not integrally cast in the components, the
component and locking ring shall be designed so that when the locking ring is placed
flush against the component, the component and locking ring shall not rotate or slide
when torque is applied. The serrated components shall have 72 serrations to enable
rotation of the disconnect hanger clevis, hub plate, or signal head in 5° increments.
922.06
1184
There shall be no thread in contact with a wearing surface. Locking rings shall be
a minimum thickness of 3/16 in. and a maximum thickness of 1/4 in. from the base of
the ring to the serration peaks. The inside diameter shall be 2 in. and the outside
diameter shall be 2 7/8 in.910
The terminal block shall have an 18-point terminal block permanently engraved
or etched with sequential numbers indicating the circuits. The terminal block shall not
have a method of connection which allows a screw point to damage wires when the
wires are securely connected. Each point of connection shall accommodate a minimum
of four No. 14 gauge wires.
The disconnect hanger shall have two side entrance holes on opposite sides
capable of receiving a 1 1/2 in. plastic or rubber insert to reduce water infiltration. It
shall be capable of supporting signal faces in the ambient temperature range of -35 to920
120°F without failure.
The balance adjuster shall have hex head bolts, lock washers, and nuts for securing
the main body of the balance adjuster firmly onto and around the eye-bolt to prevent
any twisting or turning of the head suspended below it. The span hanger shall have
two J-bolts, lock washers, and hex head nuts adequate in size to securely fasten the
hanger to a messenger cable up to 1/2 in. in diameter.
A Type C certification in accordance with 916 shall be provided for the disconnect
hanger junction box.930
922.07Signal Support Assemblies
The maximum allowable space or play between the hanger assembly and the eye-
bolt of the balance adjuster and between the balance adjuster and the weatherhead
clevis, at points where they are attached to each other by rivet pins or hex head bolts
and nuts with lock washers, shall be 0.062 in. No bushings or shims will be allowed
in this assembly.
940
The balance adjuster shall consist of a hex head bolt, a lock washer, and nuts for
securing the main body of the balance adjuster onto and around the threads of the eye-
bolt to prevent any twisting or turning of the adjuster.
The span hanger, balance adjuster, weatherhead, and all related hardware shall be
made of a non-corrosive metal or shall be hot-dip galvanized in accordance with
ASTM A153 or be mechanically galvanized and conform to the coating thickness,
adherence, and quality requirements of ASTM B695, class 55. The weatherhead shall950
have a minimum of 2 1/2 in. of exposed threads. The weatherhead shall have two set
screws to fasten the nipple to the weatherhead. If the weatherhead and threaded pipe
922.07
1185
has a slip-in connection, the locking device shall be a double nut assembly. If the
weatherhead and threaded pipe has a screw-in connection, the locking device shall be
a double set screw assembly.
The span hanger shall be furnished with two each of J-bolts, lock washers, and
hex head nuts. The J-bolt shall be a minimum of 1/4 in. diameter and shall have
sufficient threads to be able to secure the hanger to a 1/4 in. or to a 1/2 in. span cable.
960
The tether bracket shall attach to a 1/4 in. tether and prevent the bottom of the
head from moving side-to-side on the tether. Where backplates are installed on the
signal heads, the tether bracket shall be of the proper length for the backplate so that
the cable is mounted below the bottom of the backplate to avoid interference with head
alignment and damage to the backplate. Three bolts, nuts, and washers shall be used
to secure the tether bracket to a three-section or four-section signal head. A wire rope
clamp in accordance with 922.10(e)4c shall be used to secure the tether bracket to the
tether.
970
The tether bracket shall have predrilled 1/2 in. diameter holes. In lieu of the wire
rope clamp and 1/2 in. diameter holes, a beveled tether plate that completely fills in
the extruded portion of the tether bracket may be used to secure the tether bracket to
the tether. The tether bracket shall not extend more than 2 in. below the tether.
The multiple pipe arm assembly shall consist of a span hanger assembly, a balance
adjuster, a signal weatherhead, a two, three, or four- way pipe arm, 1 1/2 in. pipe, a
lower arm assembly, and all related hardware necessary for a complete assembly.
980
The two, three, or four-way pipe arms shall have a minimum of 2 in. of exposed
thread. Each arm of the pipe arm shall be furnished with two 72 serration locking rings.
One locking ring shall have a 3 in. outside diameter and one locking ring shall have a
2 3/8 in. outside diameter.
Assembly Maximum Allowable Weight
Two-way 19 lb
Three-way 25 lb
Four-way 28 lb
922.08Signal Cantilever Mount Signal Bracket
The bracket shall allow the following four adjustments:
922.08
1186
The bracket shall be fastened to the supporting arm or structure with stainless steel
bands. The bracket shall adjust to fit all sizes of round, octagonal, elliptical, or other
shape structure without special tools or equipment.
The bracket shall attach to the signal by clamping the signal head both top and
bottom and shall be designed to accommodate the specified signal configuration. Each1000
bracket shall be complete with all necessary hardware to attach the traffic signal to the
bracket and the bracket to the support.
All electrical wiring shall be concealed within the bracket, except that which runs
from the bracket to the signal cantilever arm.
Upper and lower arms shall be cast from aluminum in accordance with ASTM
B26, alloy 713.0-T5 or 356.0-T6. The vertical support tube shall be extruded from
aluminum in accordance with to ASTM B241, alloy 6061-T6 or 6063-T6, and the
strapping to attach the bracket to the arm shall be stainless steel. All steel or malleable1010
iron parts shall be hot-dip galvanized in accordance with ASTM A153 or be
mechanically galvanized and conform to the coating thickness, adherence, and quality
requirements of ASTM A153, B695, class 55.
922.09Pedestal Poles and Cast Aluminum Pedestal Bases
The pedestal base used for mounting pedestrian signal heads or control cabinets
shall be in accordance with 922.09(a). The length of the pedestal pole shall be as shown
on the plans.
A pedestal mounted G cabinet shall have a cast aluminum pedestal base. The
cabinet and pedestal base shall be ground mounted on a concrete Type A foundation
at locations and dimensions as shown on the plans.
The cast aluminum base shall be made of aluminum in accordance with ASTM
B179, alloy ANSI 319.1 or 319.2, or in accordance with ASTM B26, alloy ANSI 356.0
- T6. The square base shall include an access door and anchor bolts with nuts and
washers. The base shall be 13 3/8 in. square and 15 in. in height ±1/4 in. The weight
shall be 22 lb ±5%.
1030
The base shall be designed to support a 150 lb axial load and 11 sq ft of signal
head area rigidly mounted. For design purposes, the distance from the bottom of the
base to the center of the signal head area is 18 ft. In addition to the dead load, the base
shall be designed to withstand wind and ice loads on the specified signal head area and
on all surfaces of the support, in accordance with the AASHTO Standard Specification
for Structural Supports for Highway Signs, Luminaires and Traffic Signals. Wind
speeds used for design shall be based on a 10 year mean recurrence interval and a wind
drag coefficient of 1.2 or as shown on the plans. The base shall contain an access door,
which is 8 by 8 1/4 in. ±1/4 in. with a stainless steel hex head bolt for attaching the
door.1040
922.09
1187
The base shall be attached to a foundation by four anchor bolts, with an anchor
bolt circle of 12 3/4 in. Slotted lugs shall be integrally cast into the four corners of the
base for attachment of the anchor bolts. The anchor bolts shall be steel in accordance
with ASTM F1554, Grade 36. The diameter of the anchor bolt shall be 3/4 in. with a
minimum length of 18 in. ±1/2 in., plus 2 1/2 to 3 in. right angle hook on the unthreaded
end. The top 4 in. of the bolt shall be threaded with 10 NC threads. The threads, plus
3 in., shall be hot-dip galvanized in accordance with ASTM F2329 or be mechanically
galvanized and in accordance with the coating thickness, adherence, and quality
requirements of ASTM B695, Class 55. Each anchor bolt shall be provided with two1050
high strength heavy hex head nuts in accordance with ASTM A563 and three washers.
Two of the washers shall have a minimum 2 in. and maximum 2 1/8 in. outside
diameter and be in accordance with ANSI B 27, Type B regular series and one shall
be a nominal 3/4 in. series W washer, in accordance with ASTM F436.
The cast aluminum pedestal base shall be in accordance with the dimensions and
requirements shown on the plans. The casting shall be true to pattern in form and
dimensions, free from pouring faults, sponginess, cracks, blowholes, and free from
other defects in positions affecting the strength and value of the intended use for the
casting. The base shall not have sharp unfilleted angles or corners. The surface shall1060
have a workmanlike finish.
The door and bolt for the door shall be interchangeable on cast bases from the
same manufacturer.
The top of the base shall accommodate a pole having a 4 1/2 in. outside diameter.
The threads inside the top of the base shall be 4 in. national standard pipe threads. The
pole shall be either a steel pedestal pole or an aluminum pedestal pole.
1070
A steel pedestal pole shall be a seamless Schedule 40 carbon steel pipe in
accordance with ASTM A53, grade B. The pole shall have an outside diameter of 4
1/2 in. The pole shall weigh approximately 10.8 lb/ft. The length of the pole shall be
as shown on the plans. The pole shall have full depth national standard pipe threads
on one end of the pole. The length of threads shall be 2 1/2 in.
The pole shall be galvanized, after threading, in accordance with ASTM A123.
The threads shall be cleaned of all excess galvanizing and protected by a suitable
shield.
1080
An aluminum pedestal pole shall be in accordance with ASTM B241 for seamless
aluminum alloy, Schedule 40, 6061-T6. The outside diameter of the pole shall be 4
1/2 in. The length of the pole shall be as shown on the plans. The pole shall weigh
approximately 3.7 lb/ft. The pole shall have full depth national standard pipe threads
on one end of the pole. The length of threads shall be 2 1/2 in. and protected by a
suitable shield. The pole shall have a spun finish.
922.09
1188
A pole cap shall be supplied for the top of the pole if the pole is used for the
mounting of pedestrian signal faces or side mounted signal control cabinets. The pole1090
cap shall be either a cast pole cap of aluminum or a pole cap of spun aluminum.
A cast pole cap shall be made of aluminum, in accordance with ASTM B179,
alloy ANSI 319.1 or 319.2. The cap shall fit freely on the 4 1/2 in. outside diameter
pole. A set screw using a 3/4 in. No. 12 hex head machine screw shall be supplied to
hold the cap on the pole. A standard foundry draft will be allowed on the casting.
A pole cap made from spun aluminum shall be in accordance with ASTM B209,
alloy 1100-0. The cap shall fit tightly when placed on the end of the pole.
1100
922.10Signal Supports
All welding shall be in accordance with 711.32. Welds shall generate the full
strength of the shaft. Only longitudinal continuous welding will be allowed on the pole
shaft. Contacting joint surfaces shall be cleaned before fabrication then sealed by
means of welding. Working drawings shall be submitted in accordance with 105.02.
The steel strain pole shall be an anchor base type pole and shall include a handhole
and a pole top or cap. The poles shall be furnished in lengths specified.
1110
The pole shall have a handhole within 18 in. of the base. The pole shall have a top
or cap with a set screw that can be removed with small hand tools.
The pole material shall be in accordance with ASTM A595 or A572 with a
minimum yield strength of 50,000 psi. The pole shall be galvanized after fabrication
in accordance with ASTM A123.
All hardware, handhole cover and latching device, and band-type steel polebands
shall be hot-dip galvanized in accordance with ASTM A153 or be mechanically
galvanized and conform to the coating thickness, adherence, and quality requirements1120
of ASTM B695, Class 55. All nuts and bolts, except anchor bolts, shall be in
accordance with ASTM A307, and shall be either hot dip galvanized in accordance
with ASTM F2329 or mechanically galvanized in accordance with ASTM B695, Class
55. If a cast pole top or cap is used, it shall be in accordance with ASTM A126 and
shall be galvanized with a minimum coating of 2 oz/sq ft.
The polebands shall fit the pole as planned. The wire rope shall not be in contact
with any 90° edges or with any threads on the band. The pole band material shall be
in accordance with ASTM A572, grade 50; ASTM A606; or ASTM A36 with
minimum yield of 50,000 psi. The minimum width of the bands shall be 3 in. and the1130
bands shall be capable of supporting the pole design load. Each half of the band shall
be stamped with the corresponding size number.
922.10
1189
The pipe coupling for the weatherhead and base plate shall be installed prior to
galvanizing. The threads shall be cleaned of all excess galvanizing. An internal J-hook
shall be installed near the top of the pole for wire support.
The steel strain pole shall be capable of supporting an 8,000 lb load applied
horizontally 18 in. below the top of the pole with a maximum allowable deflection of
0.16 in. per 100 lb of load. The pole shall be tapered 0.14 in./ft of length.1140
A one-piece base plate shall be secured to the base of the pole and shall develop
the full strength of the pole. The base plate material shall be in accordance with ASTM
A36, ASTM A572, or ASTM A588. The base plate shall have four holes of adequate
size to accommodate 2 1/4 in. anchor bolts. The bolt circle shall have a 22 in. diameter
and bolt square of 15 1/2 in.
Four high strength steel anchor bolts, 2 1/4 in. in diameter and 96 in. long,
including the hook, shall be furnished with each pole. Each bolt shall have two heavy
hex nuts and two washers in accordance with ASTM A563 and F436 respectively. The1150
anchor bolt material shall be in accordance with ASTM A576 or ASTM A675 with a
minimum yield strength of 55,000 psi or ASTM A36, special quality, modified to
55,000 psi or approved equal. The threaded end of the anchor bolt shall have 12 in. of
4 1/2 NC threads and shall be galvanized the length of the threads, plus 3 in. The
threaded end shall be hot-dip galvanized in accordance with ASTM A153 or be
mechanically galvanized in accordance with ASTM B695, Class 55. The unthreaded
end of the anchor bolt shall have a standard L bend for a distance of 9 in. from the
centerline of the anchor bolt to the end of the L. In lieu of the standard bend a steel
plate 4 1/2 sq in. and 1 1/4 in. thick may be welded to the embedded end of the anchor
bolt.1160
Timber strain poles shall be made from southern yellow pine and shall be in
accordance with the current ANSI Specifications and Dimensions for Wood Poles
No. 05.1. They shall be of the length and class specified.
All poles shall be full length pressure treated by the full cell process in accordance
with current specifications as set forth in the AWPA Standards T1 and U1, Commodity
Specification D: Poles, use category UC4B using preservative as outlined in 911.02(h).
1170
Treatment, handling, and storage methods shall be in accordance with the current
AWPA Standards.
All traffic signal cantilever structures, with or without combination arm, shall be
as shown on the plans.
922.10
1190
There shall be no threads in the wearing surface plane at the point of connection1180
between the clevis clamp and the signal face assembly. The clevis clamp shall have an
11/16 in. diameter bolt hole to receive the signal face assembly.
The signal cantilever structure pole, sections 1 and 2, signal arm, and combination
arm shall be a round or multi-sided tapered tube, except the upper 4 to 6 ft of a signal
pole may be non-tapered. The pole and arms taper rate shall be 0.14 in./ft. A 1/2 in. 13
NC threaded grounding nut or approved equivalent shall be provided and be accessible
through the handhole. The pole cap shall be secured in place with setscrews. The pole
shall be provided with a removable pole cap and integral wire support hook for the
luminaire electrical cable. The cable shall be attached to the hook by a service drop1190
clamp.
The signal cantilever arm and combination arm, if required, shall be attached to
the pole as shown on the plans. The arms shall have cable inlets as shown on the plans.
All signal heads on the arm shall be attached as shown on the plans, installed parallel
to the horizontal plane, and centered to the cantilever arm. The cantilever arms shall
be used as an enclosed raceway for wiring and shall be free of burs or rough edges.
The pole top luminaire for roadway lighting, if required, shall be installed on these
structures as shown on the plans.1200
A one-piece anchor base plate shall be supplied as shown on the plans. Four
removable bolt covers shall be provided with each base and each cover shall attach to
the upright portion of the body of the base by means of one-hex head cap screw.
The signal cantilever pole, arms, base plates, arm flange plates, gusset plates, ring
stiffeners, and pole splice plates shall be in accordance with ASTM A595 or A572
with a minimum yield strength of 50,000 psi.1210
High strength heavy hex bolts for the pole splice shall be in accordance with
ASTM F3125, grade A490 and shall be coated in accordance with ASTM F1136,
Grade 3, ASTM F2833, Grade 1, or ASTM F3019, Grade 4, as shown in ASTM F3125.
The contact area for both pole splice plates shall be class B in accordance with
AASHTO Standard Specifications for Highway Bridges, Table 10.32.3C with a
minimum slip coefficient of 0.5. The surfaces shall be blast cleaned with class B
coatings. The arm flange plate connection bolts shall be in accordance with
ASTM F3125, grade A325. All other hardware shall be in accordance with ASTM1220
A307 and by either hot dip galvanized in accordance with ASTM F2329 or
mechanically galvanized in accordance with ASTM B695, Class 55. A cast pole cap
shall be in accordance with ASTM A126 and shall be galvanized with a minimum
coating of 2 oz/sq ft.
922.10
1191
Four steel anchor bolts, each fitted with two high strength heavy hex nuts and two
flat washers, shall be furnished with each pole. The anchor bolt shall be as shown on
the plans with a minimum of 15 in. of 7 NC threads on the upper end. The threads,
nuts, and washers shall be either hot dip galvanized in accordance with ASTM F23291230
or mechanically galvanized in accordance with ASTM B695, Class 55. The steel for
the bolt shall be in accordance with ASTM F1554, with a yield strength of 36,000 or
55,000 psi.
All steel material shall be fully galvanized. Galvanizing shall take place after all
welding is accomplished and holes cut.
Working drawings and design calculations shall be submitted in accordance with1240
105.02
Pole anchors shall be 8-way expanding with a minimum area of 135 sq in. when
expanded or a 10 in. diameter screw anchor. They shall have a minimum holding
strength of 10,000 lb. They shall be painted and in accordance with ASTM A575.
Anchor rods for expanded anchors shall be 3/4 in. diameter steel and for screw anchors
shall be 1 1/4 in. diameter steel, 8 ft long, in accordance with ASTM A659, and be
galvanized in accordance with ASTM A153.
1250
Guy guards shall be made of 18 gauge galvanized steel, polyethylene, polyvinyl
chloride, or melamine phenolic, and shall be 7 ft long. The steel guy guard shall have
a tight gripping, non-scarring hook for quick attachment to the guy wire. The bottom
shall have a clamp that fits over the anchor rod and securely grips by tightening the
bolt. Steel guy guards shall be in accordance with ASTM A659. The nonmetallic guy
guard shall be a helical pigtail which shall resist upward movement, a lock strap to
secure the lower end, and a guy guard sleeve. Non-metallic guy guards shall be gray
or yellow.
Messenger cable shall be zinc-coated steel wire strand, contain seven wires, and
have a nominal diameter of 3/8 in. The cable shall be in accordance with ASTM A475,
Siemens-Martin Grade.
Span, catenary, and downguy cable shall be aircraft cable for non-aircraft use, be
3/8 in. nominal diameter, made of stainless steel wire, and consist of seven, 19-wire
922.10
1192
flexible steel strands. The 3/8 in. cable shall have a minimum breaking strength of1270
12,000 lb. It shall be in accordance with Military Specifications MIL-W-83420D.
Tether and support cable shall be aircraft cable, for non-aircraft, and shall be 1/4
in. nominal diameter, made of stainless steel wire, and consist of seven, 19-wire
flexible steel strands. The 1/4 in. cable shall have a minimum breaking strength of
6,400 lb. It shall be in accordance with Military Specifications MIL-W-83420D.
1280
Messenger hangers shall be either a 3-bolt clamp or a 3/8 by 1 3/4 in. steel hanger
with a 90° bend extending from the pole 3 3/4 in. The hanger shall have a curved
groove and clamp capable of receiving a 5/16 to 1/2 in. cable.
The messenger shall be clamped by two 1/2 in. high carbon steel bolts. The angle
hanger shall be mounted with a 5/8 in. through bolt and a 1/2 in. lag screw. The three-
bolt clamp shall be mounted with a 5/8 in. through bolt. The angle hanger shall be in
accordance with ASTM A575. The bolts shall be in accordance with NEMA PH 23.
1290
Cable rings shall be galvanized steel in accordance with IMSA 51-1.
Clamps shall be made of 3/8 in. steel and in accordance with ASTM A575.
Two bolt clamps shall be a minimum of 3 3/4 in. long and 1 1/4 in. wide with two
1/2 in. bolts which shall clamp cable of 1/8 to 1/2 in. diameter.
Three bolt clamps shall be a minimum of 6 in. long and 1 5/8 in. wide with three1300
5/8 in. bolts which shall clamp cable of 5/16 to 1/2 in. diameter.
The bolt heads shall be large enough to provide maximum clamping area and shall
have oval shoulders to prevent the bolts from turning while tightening. The bolts shall
be in accordance with NEMA PH 23.
Servi-sleeves shall be 1 1/4 to 2 1/4 in. in length and shall hold the size of the
cable specified. The sleeves shall be in accordance with ASTM A659.
1310
Straight eye-bolts shall be 3/4 in. diameter drop forged steel, a minimum of 14 in.
long, and have 6 in. of thread. The steel washers shall be 2 1/4 by 2 1/4 by 3/16 in. in
size with a 13/16 in. hole in the center. All parts shall be in accordance with
ASTM A575 and shall be galvanized in accordance with ASTM A123.
922.10
1193
Hub-eyes shall be made of drop forged steel and in accordance with ASTM A575.
They shall receive a 3/4 in. mounting bolt and have a full rounded thimble eye for
protection of the guy cable.1320
922.11Signal Cable
Signal hook-up wire shall be stranded one conductor wire, Type THW seven
strand No. 14 AWG, with a thermoplastic sheath 3/64 in. thick and a 600 volt rating.
Insulation shall be color-coded, as required, and labeled with gauge, voltage rating,
and insulation type.
Signal control cable shall be in accordance with IMSA 19-1 or 20-1 and shall be
stranded No. 14 AWG wire.
Traffic signal service cable shall be color coded, stranded copper No. 8 AWG
wire, three conductor cable, Type THWN.
922.12Signal Interconnect
Integral aerial interconnect cable shall be figure “8” self-supporting type cable
consisting of a messenger cable and seven conductors No. 14 AWG signal cable in
accordance with IMSA 20-3.
Six pair telemetry cable shall contain six twisted pairs of 19 gauge conductors and
shall be in accordance with IMSA 40-2 for underground application and IMSA 40-4,
integral messenger, for aerial application.
Fiber optic cable shall contain 12-strand multimode, graded index, optic fibers
with a minimum of one non-metallic central strength member. The cable shall be gel-
free design, loose tube, all dielectric construction, suitable for outdoor use in conduit
or on aerial supports. Each length of fiber optic cable in nonmetallic conduit shall
include a No. 14 AWG aluminum or No. 6 AWG copper tracer wire.
Each individual fiber shall be 2.5/5 mils (62.5/125 μm) diameter, core/color-
coded clad, and each color-coded set of fibers shall be encased in a loose tube buffer
with water blocking tape on the outside and fully water blocked inside using craft-
friendly, water-swellable yarns. The fiber optic cable shall be constructed with Kevlar1360
braid and outer polyethylene jackets as a minimum. If an inner jacket is used, it shall
922.12
1194
be PVC. Maximum attenuation of the cable shall be 4.0 dB/km nominal, measured at
room temperature at 850 nm. The bandwidth shall not be less than 160 MHz/km, also
at 850 nm. Each fiber shall be continuous with no factory splices except for joining
standard length cables to form longer, continuous jacketed cable to fit installation
requirements. The cable shall have standard nylon rip cords. Kevlar rip cords will not
be accepted.
The cable shall be in accordance with the generic requirements for optical fiber
and optical fiber cable per ANSI/ICEAS-104-696 design and test criteria.1370
The exterior of the polyethylene outer cable jacket shall be stenciled so that every
16.4 ft on each reel is marked with a number. The 16.4 ft of each reel shall be marked
with a 5, the 32.8 ft marked with a 10, and so on until the end of the reel. The stencil
shall be applied to the outer jacket using permanent ink and shall be permanently
engraved into the jacket to provide long lasting readability.
Spread spectrum radio modems for communications between local controllers and
the system master controller shall be on the QPL of Traffic Signal and ITS Devices.1380
922.13Detection Components
Runs 700 ft and less of loop detector lead-in cable shall be in accordance with
IMSA 50-2 and shall be stranded two conductor No. 16 AWG, 19 strands of No. 29
wire.
Runs greater than 700 ft shall use 14 AWG wire. The nominal capacitance
between conductors shall be 57 pF/ft and 98 pF/ft between one conductor and the other1390
conductor connected to the shield.
Roadway loop wire shall be 14 AWG gauge IMSA 51-7 duct-loop wire with
polyvinyl chloride or polyethylene outer jacket of 1/4 in. diameter.
Other vehicle detection systems shall be selected from the QPL of Traffic Signal
and ITS Devices.
1400
922.14Ground Wire
The ground wire shall be copper wire No. 6, AWG soft-drawn, solid copper in
accordance with ASTM B3.
922.15Splicing Kit
Splicing kits shall contain a two-piece, transparent snap-together mold body and
include an epoxy and sealing compound contained in a unipak. It shall be capable of
922.13
1195
insulating and splicing nonshielded cables rated up to 5 kilovolts and multi-conductor
cables rated up to 600 volts.
1410
922.16Ground Rod and Connections
Ground rods shall be 1/2 in. in diameter by 8 ft long with a machined point and
chamfered top. They shall be made of steel with a molecularly bonded outer layer of
electrolytically applied copper. A single electrode shall have a maximum resistance to
ground of 25 ohms. Single electrodes that do not have resistance to ground of 25 ohms
or less shall be augmented by additional electrodes, grids, or plates until resistance to
ground of 25 ohms or less is achieved. Resistance shall be measured using a three-
point ground tester using the fall of potential method. Data, graphs, resistance in ohms,
date of test, make and model of ground tester, and the individual’s initials performing
the test shall be recorded and submitted to the District Office. Resistance in ohms shall1420
be tagged at the ground connection.
The finished rod shall be cold-drawn and shall have the following minimum
physical properties:
Physical Property Value
Tensile strength, min. 97,000 psi
Yield strength, 0.2% offset, min. 85,000 psi
% of elongation 13 - 40
The ground rod and wire connection shall be made by a thermo weld process or
approved equal. The welding material shall cover and secure the conductor to the rod
and shall be porous free.
1430
An acceptable alternate shall be a ground grid connection properly sized and shall
consist of a shear head bolt, a “C” shaped body, nest, and wedge. The connector
components shall be fabricated from an aluminum-bronze alloy, silicone-bronze alloy,
or copper.
922.17Handholes
A Type I handhole shall be made of class III reinforced concrete pipe with a cast
iron ring and cover. The concrete shall be in accordance with section 907.02.1440
Reinforcement shall be provided as shown on the plans or in accordance with the
manufacturer’s design. If reinforcement deviates from the plans, provide calculations
showing that the modified design supports HS-20-44 loading. The ring and cover for
handholes shall be in accordance with 910.05(b).
A Type II handhole shall be made of polymer concrete or other material that is
certified to be in accordance with ANSI/SCTE 77 and meet or exceed Tier 22 loading
requirements. The handhole shall be stackable.
922.17
1196
1450
The handhole box shall be heavy duty. The inner surface of the handhole shall be
smooth and free from cracks and imperfections.
The cover shall be marked with logo imprints of “TRAFFIC SIGNAL” and the
ANSI/SCTE Tier rating - “TIER XX”. The cover shall be secured with stainless steel,
300 series, 3/8 in., 16 NC hex bolts and washers. The cover shall have a friction
coefficient of at least 0.5.
1460
A Type III handhole shall be AASHTO HS-20 rated. The handhole box shall be
concrete. The ring and cover shall be steel and shall be secured to the handhole box.
922.18Entrance Switch
The entrance switch shall be a double pole, 50A, 120V AC circuit breaker in a
NEMA Type 3R enclosure in accordance with NEMA 250-2008. The minimum
dimensions of the enclosure shall be 5 in. wide, 3 3/4 in. deep and 9 1/4 in. high. A 1
in. rain-tight detachable hub shall be supplied in the top of the enclosure. The enclosure
shall have knockouts on the sides, bottom and back with diameters of 7/8 in. to 1 3/41470
in. The enclosure shall contain the circuit breaker, an insulated solid bar for connection
of AC neutral, a separate lug for attachment of earth ground, have provisions for a
padlock, and shall be surface mounted.
The enclosure shall be made of galvanized steel with a rust inhibiting treatment
and finished in the manufacturer’s standard color of baked enamel.
All wire terminations and breaker to buss-bar contact points inside the enclosure
shall be coated with an anti-oxidant to prevent oxidizing and corrosion of components.
1480
922.19Conduit and Fittings
Steel conduit, couplings, and elbows shall be galvanized rigid steel conduit in
accordance with UL 6. The conduit shall be galvanized by the hot dip method on the
interior and exterior surfaces. Conduit threads shall be cut after galvanizing. The
conduit shall be supplied with a threaded coupling attached to one end and the other
threaded end protected by a suitable shield.
The various conduit fittings such as bands, bodies, straps, lock nuts, and threadless1490
connectors, shall be in accordance with Federal Specifications A-A-50553, and shall
be galvanized if not stainless steel. Conduit straps shall be two hole straps with a
minimum thickness of 1/8 in. Conduit lock nuts 3/8 to 1 1/2 in. in size shall be made
of steel. Other sizes shall be made of either steel or malleable iron. All conduit lock
nuts shall be galvanized. Other nuts shall be either stainless steel or galvanized steel.
922.18
1197
Conduit, fittings, and accessories shall be manufactured from PVC meeting
ASTM D1784 and shall comply with all the applicable requirements of NEMA TC2
and UL 651. Each length of pipe shall include a coupling.1500
Rigid fiberglass conduit and fittings shall be filament wound consisting of E-glass
and corrosion resistant epoxy resin manufactured for use at temperatures from -40 to
230°F. Rigid fiberglass conduit shall be pigmented with carbon black for ultraviolet
protection and fire resistant per UL 94. All rigid fiberglass conduit shall have tracer
wire, be heavy walled, HW, and meet the specifications, labeling, and testing of
ANSI/NEMA TC9.
Conduit shall be smooth wall, Type III, Grade P-33, Category 5, Class C, coilable,
HDPE. SDR 13.5 may be used for Schedule 40 HDPE and SDR 11 may be used for
Schedule 80. Conduit and fittings shall meet the applicable requirements of ASTM
D1248, ASTM D3350, ASTM F2160 and UL 651.
Schedule 40 or 80 HDPE conduit shall be marked in accordance with ASTM
D3485 with the producer code and designation type indicated. HDPE conduit shall be
produced from material with an orange color and ultraviolet stabilization code of C,
D, or E in accordance with ASTM D3350. Schedule 40 HDPE conduit for use above
ground shall be black.1520
922.20Detector Housing
The entire housing casting shall be made from aluminum alloy in accordance with
ANSI 320.
922.21Certification
A Type C certification in accordance with 916 shall be provided for traffic signal
materials and equipment unless otherwise specified.