906.01Joint Fillers
Joint fillers shall be preformed materials intended to be used in PCCP or as otherwise specified. Joint fillers sha ll be in accordance with AASHTO M 213 or ASTM D8139. A Type B certification in acco rdance with 916 shall be provided for joint fillers. The limits of the following shall be shown on the certification.
Property Test Method Asphalt Content ASTM D545 Compressive Strength ASTM D8139 Density ASTM D545 Extrusion ASTM D545 Freeze Thaw Resistance ASTM D8139 Heat Resistance ASTM D8139 Recovery ASTM D8139 Water Absorption ASTM D545
906.02Joint Sealing Materials 10
Joint sealers shall consist of materials which are intended to be used in sealing joints and cracks in pavements and structures.
Silicone joint sealants shall be in accordance with ASTM D5893.
All silicone joint sealants complying with the physical requirements will be subjected to a field evaluation before approval for general use is granted. The 905.06
Department will maintain a QPL of Joint Sealants, which comply with the physical requirements and field evaluation.
The sealant shall be stored in the original unopened container at or below 90°F. The sealant shall be placed when the ambient temper ature is above 40°F. The equipment used shall be adequate for the placement of the sealant and shall meet the 30 sealant manufacturer’s recommendations. Air compressors used for the placement of this sealant shall be equipped with traps which remove moisture and oil from the air.
The sealants which are self-leveling shall be identified as such on the QPL of Joint Sealants and will not require tooling. Sealants not identified as self-leveling on the QPL shall be tooled or applied to wet th e joint faces. Sealants which are not self- leveling will not position properly in the joint under their own weight. A backer rod as set out herein shall be used to control sealant configuration and facilitate tooling. Joint configurations shall be as shown on the plans. After a joint has been sealed, all surplus joint sealer on the pavement surfaces shall be promptly removed. Traffic shall 40 not be allowed over sealed joints until the sealer is tack free.
The sealant shall be delivered in containers plainly marked with manufacturer’s name or trademark.
The sealant shall be in accordance with ASTM D6690, Type II. The material shall be tested in accordance with ASTM D5329 except that after blo tting, the surface of the blocks shall be blown dry with compressed air. A Type A certification in accordance with 916 shall be provided for hot poured joint sealant. The results of the 50 following shall be shown on the certification.
Property Requirements Cone Penetration at 25°C 90 maximum Softening Point °C 80 minimum Bond, non-immersed Three 12.5 ±0.2 mm specimens pass 3 cycles at 50 % ext. at -29°C Resilience, % 60 minimum Asphalt Compatibility Pass
The sealing compound shall be delivered in the manufacturer’s original sealed container. Each container shall be legibly marked with the name of the manufacturer, the trade name of the sealer, the manufact uring batch number or lot, the pouring temperature, and the safe heating temperature.
The sealant shall be used in accordance with the manufacturer’s recommendations. A backer rod as set out herein shall be used to provide the joint configuration in 60 accordance with the standard drawings. 906.02
This joint shall be in accordance with ASTM D2628. A Type A certification in accordance with 916 shall be provided for joint seals. The results of the following shall be shown on the certification.
Property ASTM Test Method Requirements Tensile strength, minimum, psi (MPa) D412 2000 (13.8) Elongation at break, minimumௗ D412 250 Hardness, Type A durometer, points D2240 55 ±5 Oven aging, 70 h at 212°F (100°C) D573 Tensile strength, loss, maximumௗ 20 Elongation, loss, maximumௗ 20 Hardness, Type A durometer, points change WRௗௗ Oil Swell, ASTM Oil 3, 70 h at 212°F (100°C) :HLJKWFKDQJHPD[LPXPௗ D471 45 Ozone resistance D1149 ௗVWUDLQSSPLQDLUKDW)& no cracks Low-temperature stiffening, 7 days at 14°F (-10°C) D2240 Hardness, Type A durometer, points change WRௗௗ Low-temperature recovery, 72 h at 14°F (-&ௗGHIOHFWLRQPLQLPXPௗ D2628 88 Low-temperature recovery, KDWௗ-ௗ)-29°C), ௗGHIOHFWLRQPLQimum,ௗ D2628 83 High-temperature recovery, 70 h at 212°F (100°C), ௗGHIOHFWLRQPLQimum, ௗ D2628 85 Compression-GHIOHFWLRQDWௗRIQRPLQDOZLGWK minimum, lbf/in. (N/m) D2628 3.5 (613)
Polychloroprene joint membrane shall be general purpose, heavy duty 70 polychloroprene sheeting with nylon fabric reinforcement. The sheeting shall be in accordance with the following:
Property Test Method Requirements Thickness ASTM D751 0.094 in. ±0.01 in. Breaking Strength, Grab Test, minimum ASTM D751 700 lbf x 700 lbf (Longitudinal x transverse) Adhesive Strip, 1 in. by 2 in. ASTM D751 9 lbf minimum Burst Strength ASTM D751 1,400 psi minimum
906.02
A Type B certification in accordance with 916 shall be provided for the polychloroprene joint membrane. The limits of the above shall be shown on the certification.
The adhesive used to attach the polychlor oprene joint membrane to concrete shall be a black styrene-butadiene rubber base material compatible with both concrete and 80 polychloroprene. The adhesive shall be in accordance with the following:
Property Test Method Minimum Maximum Viscosity, cps ASTM D2196, RVF #6 sp @ 20 rpm 7,500 18,000 Solids, % ASTM D1259 28 35 Weight per gal., lb ASTM D1875 6.6 7.0
A Type C certification in accordance with 916 shall be provided for the polychloroprene joint membrane adhesive.
Joint adhesive is a hot applied asphalt material that is used to seal the longitudinal construction joint formed between the adjacent HMA pavement courses.
Joint adhesive shall be in accordance with the following:
Test Method Test Result Softening Point, °F (°C) AASHTO T 53 > 170 (77) Ductility @ 77°F (25°C), mm AASHTO T 51 > 300 Ductility @ 39°F (4°C), mm AASHTO T 51 > 300 Apparent Viscosity @ 400°F (204°C), cP ASTM D2669 4,000 – 11,000 Asphalt Compatibility ASTM D5329 Pass Cone Penetration @ 77°F (25°C), mm ASTM D5329 50.0 – 100.0 Flow @ 140°F (60°C), mm ASTM D5329 < 5 Resilience @ 77°F (25°C), % ASTM D5329 > 30 Tensile Adhesion @ 77°F (25°C), 1 in. specimen, % ASTM D5329 > 500 Flexibility @ 0°F (-18°C) ASTM D3111 Pass Flash Point, °C (°F) AASHTO T 48 > 219 (426)
A Type A certification in accordance with 916 shall be provided for hot poured joint adhesive. The results of the above shall be shown on the certification.
The rod is to act as a bond breaker, to control the thickness of the bead, and to provide support for any required tooling of the sealant.
906.02
When hot poured material is used, compatibility of the backer rod with the hot sealant shall be verified before use. The backer rod shall be a closed cell expanded polyethylene foam or an isomeric polymer foam rod. Diameter and placement shall be as shown on the plans.
A Type C certification in accordance with 916 shall be provided for the backer rod.
906.03Preformed Expansion Joint Filler
Preformed expansion joint filler, PEJF, shall be preformed materials intended to be used at bridge component interfaces that are not required to be watertight. PEJF shall be either extruded polystyrene, XPS, or expanded polystyrene, EPS in accordance with ASTM C578. The compressive resistance shall be less than 40 psi, as measured in accordance with ASTM D1621. Water absorption shall be less than 1%, as measured in accordance with ASTM C272. PEJF will be by accepted by visual inspection.
906.04Blank 120
906.05Blank
906.06Blank
906.07Bridge Expansion Joints
Type SS and Type M joints, including anchor assemblies, shall be shop fabricated, delivered, and installed as a continuous unit for lengths up to 46 ft. Joints longer than 46 ft shall be furnished in continuous units or in appropriate shorter sections as shown on the working drawings and approved by the Engineer. Joints used in stage 130 construction shall be furnished in sections appropriate to accommodate the work. All steel joints furnished in sections shall be spliced with welds, with ends prepared for welding in the shop. All welds shall be in accordance with 711.32.
The profile of the joint in the roadwa y area shall conform to the roadway cross- section. Where changes in direction are required, such as at curbs or concrete rails, the sections shall be cut to the bevel required to produce the same cross-section on each piece being joined. Slider plates shall be pr ovided at curbs, walkways, and concrete rails as part of the completed joint assembly. The slider plate shall be the same material as the extrusion and shall be galvanized in accordance with ASTM A123. 140
All exposed structural steel surfaces, except stainless steel or polytetrafluoroethylene coated, shall be shop painted in accordance with 619.
Type PCF joints shall be fabricated, delivered, and installed in lengths no less than 6 ft. Sections of joint shall be field spliced using silicone sealant in accordance with 906.03
the manufacturer’s recommendations. Joints shall be furnished with the fewest number of splices possible, and sections less than 6 ft in length shall not be used unless required to complete the remaining length at the ends of a joint or construction phase.
This joint shall consist of preformed elastomeric strip seals and the corresponding steel locking edge rail.
Structural steel shall be in accordance with ASTM A36, ASTM A242, ASTM A588, ASTM A1011, or M 1010 or M 1020 in accordance with ASTM A575.
Sealant and grout shall be in accordance with the manufacturer’s recommendation.
The elastomeric compound used to manufacture the strip seal shall be neoprene and in accordance with ASTM D5973.
The strip seal shall be furnished in one continuous length for the entire limits of the installed joint. The strip seal shall not be field-spliced. Miter cut, vulcanized shop splices will be required in the strip seal. The shop vulcanization of the strip seal splice may be either a hot or cold process so long as the process produces a splice of equal or greater strength than the elastomer.
A Type B certification in accordance with 916 shall be provided for the 170 elastomeric strip seal. The limits of the following shall be shown on the certification.
Property Requirements Tensile Strength ASTM D412 Elongation at break ASTM D412 Hardness, Type A durometer, points ASTM D2240 (modified) Oven Aging Tensile Strength, loss Elongation, loss Hardness, Type A durometer, points change ASTM D573 Oil Swell, IRM 903, weight change ASTM D471 Ozone Resistance ASTM D1149 Low Temperature Stiffening ASTM D2240 Compression set ASTM D395, Method B
A Type C certification in accordance with 916 shall be provided for the structural steel and polyurethane sealant.
( b ) T y p e M This joint shall consist of prefabricated multiple elastomeric seals, separator beams, and support bars. The structural design of the joint shall be in accordance with 906.07
AASHTO LRFD Bridge Construction Specifications. The joint shall be designed to 180 accommodate the movement shown on the plans.
The joint assembly shall be preset by the manufacturer in accordance with the
approved working drawings, joint setting data, and specifications. The assembly shall
be properly secured for shipping and contain provision for final field adjustment at the
time of installation. The manufacturer shall furnish a copy of the installation
instructions prior to the placement of these joints.
Structural steel shall be in accordance with ASTM A36, ASTM A242, ASTM
A588, ASTM A1011, or M 1010 or M 1020 in accordance with ASTM A575.190
Sealant and grout shall be in accordance with the joint manufacturer’s
recommendation.
The elastomeric compound used to manufacture the seal shall be neoprene in
accordance with ASTM D5973.
A Type B certification in accordance with 916 shall be provided for the
elastomeric seal. The limits of the following shall be shown on the certification.
200
Property Requirements
Tensile Strength ASTM D412
Elongation at break ASTM D412
Hardness, Type A durometer, points ASTM D2240 (modified)
Oven Aging
Tensile Strength, loss
Elongation, loss
Hardness, Type A durometer, points change
ASTM D573
Oil Swell, IRM 903, weight change ASTM D471
Ozone Resistance ASTM D1149
Low Temperature Stiffening ASTM D2240
Compression set ASTM D395, Method B
A Type C certification in accordance with 916 shall be provided for the structural
steel and polyurethane sealant.
Bearings above and below the support bar shall be a nylon or urethane compound
with polytetrafluorethylene riding surfaces. All components of the system shall be
accessible to periodic inspection and component replacement if necessary.
The seals shall be in accordance with the requirements as follows:
210
limits of joint movement,
906.07
1025
clamped in position to produce a watertight seal,
during normal joint operation,
normal limits of joint movement,
230
mechanical equilibrium control spacers or a strip seal
configuration for joints using a mechanical linkage to maintain
equidistant separator beam spacing. The joint shall have a
maximum opening of 3 in. per seal.
The separator beams shall be in accordance with the requirements as follows:
240
traffic loads by use of a suitable shape and connection to the
support bar,
bars,
equilibrium type control spacers to counter the compressive
forces of the seals or through a positive horizontal mechanical
linkage or proportioning bar.
The support bars shall be in accordance with the requirements as follows:
resistance to joint movements,
906.07
1026
lifting, to transmit bearing loads, and to maintain positioning of
the bar.
All support bar boxes and joint housings shall have top, bottom, and sides made
of steel plate with 1/2 in. minimum thickness. Anchorages shall consist of looped No.
5 reinforcing bars welded to 1/2 in. steel plates spaced at 9 in. centers. Non-welded
steel to steel contact will not be allowed.
This joint shall be furnished from the QPL of Type PCF Bridge Joints. Joints will270
be considered for inclusion on the QPL by completing the requirements of ITM 806,
Procedure C.
These products shall consist of a highway grade silicone faced self-expanding
foam expansion joint seal, a field-applied epoxy adhesive, and a field-applied silicone
sealant. The foam seal shall be able to accommodate the thermal movement range
shown on the plans and shall have a movement capability of no less than +50% to
- 50% of the nominal material size. The silicone facing material shall accommodate a
minimum elongation of 600%.
280
The foam seal shall be accordance with the following requirements:
Property Test Method Requirements
Temperature Service Range ASTM C711 -40ºF to 185ºF
UV Resistance ASTM G155 or
ASTM C793
No changes or cracking
at 2,000 h
906.08High Density Bearing Strip
The strip shall be nontoxic multipolymer plastic in accordance with the following
requirements:
Property Test Method Requirements
Compressive Strength ASTM D695 8,000 to 9,000 psi
Coefficient of Linear
Expansion ASTM D696 7.62 x 10 -4 mm/mm/ºC to
1 . 27 x 1 0 - 3 m m / m m / º C
A Type B certification in accordance with 916 shall be provided for the high-
density bearing strip. The limits of the compressive strength test and measurement of290
the coefficient of linear expansion shall be shown on the certification for the high-
density bearing strip.
906.08