3128Aggregate for Use in Masonry Mortar

MN · 2025 Standard Specifications✓ Full text on BuildSpecBook pages 850–0 Save this section

Ask about Section 3128

Get a cited answer from the section text. Click the citation to check it.

One cited answer a day is free. Start a 14-day trial for unlimited, no card required.

3128.1SCOPE

Provide fine Aggregate for use in masonry mortar.

3128.2REQUIREMENTS

Provide Aggregate for use in masonry mortar meeting the requirements of ASTM C144, Standard Specification for Aggregate for Masonry Mortar. The gradation requirements of ASTM C144 are shown in Table 3128.2-1. Table 3128.2-1 Mortar Aggregate Gradation Limits Sieve Size Percent Passing No. 4 100 No. 8 95 – 100 No. 16 70 – 100 No. 30 40 – 75 No. 50 10 – 35 No. 100 2 – 15 No. 200 0 – 5

The Engineer may allow Aggregate meeting the gradation requirements of 3126.2C, “Gradation Requirements,” for joints thicker than 1/2 inch.

3128.3SAMPLING AND TESTING — BLANK

Get an email when 3128 changes

Minnesota revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Minnesota Standard Specifications for Construction, 2025 Edition. Pages 850–0 of 1,081. View official source ↗