804.1Description.
This work consists of providing, placing, operating, relocating, and maintaining portable light assemblies.
804.2Materials.
Not applicable.
804.3Construction.
portable light assembly except when placing the portable light assembly behind guardrail, barrier, or other means of positive protection. Place plastic drums in advance of each portable changeable message sign located within the clear zone and as directed by the engineer. 804.3.1 Operational Requirements.
MUTCD. Position the portable light assembly so that it does not shine light directly at oncoming traffic. Extend the light assembly vertically to the unit’s fullest extent and direct the lights downwards toward the work area but not exceeding more than 60-degrees measured off of the ground to prevent glare. Use channelization devices in accordance with the DE MUTCD to delineate the portable light assembly.
notification of an operational problem. Failure to correct the problem within the required timeframe will result in no payment for the day that the unit did not work.
related to the portable light assembly. Provide an ATSSA traffic control supervisor in accordance with Section 812. If the contract does not require an ATSSA traffic control supervisor, the contractor may use a superintendent or other designee as the on-site representative. When a portable light assembly used to illuminate a flagger station fails to work, remove the flagger from the roadway. Restore the roadway to normal operations until a working portable light assembly is provided and placed unless opening the roadway to normal operations presents a safety hazard to motorists.
version of the AASHTO Roadside Design Guide or store in accordance with the Standard Construction Details when no longer needed.
804.4Method of Measurement.
calendar day.
804.5Basis of Payment.
unit price per each day. Price and payment constitute full compensation for providing, placing, operating, maintaining, fueling, and relocating portable light assembly units.
assemblies with Section 805. ITEM DESCRIPTION UNIT 804001 PROVIDE AND MAINTAIN PORTABLE LIGHT ASSEMBLY EA-DY
Get an email when 804 changes