844.1Description.
This work consists of providing, assembling, wiring, and installing emergency preemption detectors on a mast arm or span wire.
844.2Materials.
Equal.
844.3Construction.
mounting hardware.
preemption detector in accordance with the contract. Attach the 4-conductor detector cable to the 4 terminal screws within the emergency preemption detector unit, in accordance with the manufacturer’s specifications.
different color to denote the direction of the detector as follows:
844.4Method of Measurement.
The Department will measure the quantity of emergency preemption detector installations as the number provided, assembled, and installed on span wire or traffic signal mast arms, and accepted.
844.5Basis of Payment.
The Department will pay for emergency preemption detectors provided, assembled, installed, and accepted at the contract unit price. Price and payment constitute full compensation for providing, assembling, and installing the emergency preemption detectors and removing and delivering replaced units and hardware to the Department. ITEM DECRIPTION UNIT 844001 PROVIDE AND INSTALL OPTICOM EMERGENCY PREEMPTION DETECTOR EA