Pipe Culverts Art. 542.02 SECTION 542. PIPE CULVERTS
542.02 Materials. Materials shall be according to the following.
Item Article/Section
a.Galvanized Corrugated Steel Pipe ..................................................... 1006.01
b.Galvanized Corrugated Steel Pipe Arch ............................................ 1006.01
c.Bituminous Coated Corrugated Steel Pipe ........................................ 1006.01
d.Bituminous Coated Corrugated Steel Pipe Arch ................................ 1006.01
f.Aluminized Steel Type 2 Corrugated Pipe ......................................... 1006.01
g.Aluminized Steel Type 2 Corrugated Pipe Arch ................................. 1006.01
h.Precoated Galvanized Corrugated Steel Pipe ................................... 1006.01
i.Precoated Galvanized Corrugated Steel Pipe Arch ........................... 1006.01
j.Corrugated Aluminum Alloy Pipe ....................................................... 1006.03
k.Corrugated Aluminum Alloy Pipe Arch ............................................... 1006.03
l.Extra Strength Clay Pipe ................................................................... 1040.02
m.Concrete Sewer, Storm Drain, and Culvert Pipe ..................................... 1042
n.Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe (Note 3) .... 1042
o.Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe (Note 3) ........................................................................ 1042
p.Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe. (Note 3) ....................................................................... 1042
q.Polyvinyl Chloride (PVC) Pipe ........................................................... 1040.03
r.Corrugated Polyvinyl Chloride (PVC) Pipe with a Smooth Interior ..... 1040.03
s.Corrugated Polypropylene (CPP) Pipe with Smooth Interior ............. 1040.08
t.Corrugated Polyethylene (PE) Pipe with a Smooth Interior ............... 1040.04
u.Polyethylene (PE) Pipe with a Smooth Interior .................................. 1040.04
v.Rubber Gaskets and Preformed Flexible Joint Sealants for Concrete Pipe .................................................................................... 1056
w.Mastic Joint Sealer for Pipe .................................................................... 1055
x.External Sealing Band ............................................................................ 1057
y.Fine Aggregate (Note 1) .................................................................... 1003.04
z.Coarse Aggregate (Note 2) ................................................................ 1004.05 (aa) Packaged, Dry, Rapid Hardening Mortar or Concrete ............................. 1018 (bb) Nonshrink Grout ................................................................................. 1024.02 (cc) Reinforcement Bars and Welded Wire Reinforcement ...................... 1006.10 (dd) Handling Hole Plugs .......................................................................... 1042.16 Note 1. The fine aggregate shall be moist. Note 2. The coarse aggregate shall be wet. Note 3. Pipe culverts (jacked) shall be tongue and groove type joint and not less than a Class IV pipe. A rt. 542.03 Pipe Culverts .03 Material Permitted. When a Class of pipe is specified, the material shall be selected from the following table. When a particular material is specified, no other kind of material will be permitted. Class Materials A Rigid Pipes: Extra Strength Clay Pipe Concrete Sewer Storm Drain and Culvert Pipe, Class 3 Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe C Rigid Pipes: Extra Strength Clay Pipe Concrete Sewer Storm Drain and Culvert Pipe, Class 3 Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe Flexible Pipes: Aluminized Steel Type 2 Corrugated Pipe Aluminized Steel Type 2 Corrugated Pipe Arch Precoated Galvanized Corrugated Steel Pipe Precoated Galvanized Corrugated Steel Pipe Arch Corrugated Aluminum Alloy Pipe Corrugated Aluminum Alloy Pipe Arch Polyvinyl Chloride (PVC) Pipe Corrugated Polyvinyl Chloride (PVC) Pipe with a Smooth Interior Polyethylene (PE) Pipe with a Smooth Interior Corrugated Polypropylene (CPP) Pipe with Smooth Interior D Rigid Pipes: Extra Strength Clay Pipe Concrete Sewer Storm Drain and Culvert Pipe, Class 3 Reinforced Concrete Culvert, Storm Drain, and Sewer Pipe Reinforced Concrete Elliptical Culvert, Storm Drain, and Sewer Pipe Reinforced Concrete Arch Culvert, Storm Drain, and Sewer Pipe Flexible Pipes: Galvanized Corrugated Steel Pipe Galvanized Corrugated Steel Pipe Arch Bituminous Coated Corrugated Steel Pipe Bituminous Coated Corrugated Steel Pipe Arch Aluminized Steel Type 2 Corrugated Pipe Aluminized Steel Type 2 Corrugated Pipe Arch Precoated Galvanized Corrugated Steel Pipe Precoated Galvanized Corrugated Steel Pipe Arch Corrugated Aluminum Alloy Pipe Corrugated Aluminum Alloy Pipe Arch Polyvinyl Chloride (PVC) Pipe Corrugated Polyvinyl Chloride (PVC) Pipe with a Smooth Interior Corrugated Polyethylene (PE) Pipe with a Smooth Interior Polyethylene (PE) Pipe with a Smooth Interior Corrugated Polypropylene (CPP) Pipe with Smooth Interior W hen metric sizes are specified on the plans, the next larger available manufactured English pipe may be substituted at no additional cost to the Department. P ipe Culverts Art. 542.03 For PE pipe culverts, where no end treatment is specified, a standard corrugated PE coupling shall be provided for each exposed end of the pipe. The coupling shall be installed flush with the end(s) of the pipe. The Contractor may, at no additional cost to the Department, substitute a stronger pipe of the same kind of material specified. When a pipe diameter is specified, only a circular pipe will be permitted. When a round size equivalent is specified, only elliptical or arch pipe will be permitted. The kind of material and thickness or thickness class required for the various types of pipe culverts shall be according to Tables IA - IC, IIA, IIB, and IIIA – IIIC and the following.
a.Steel or aluminum alloy arch and concrete elliptical or arch pipes will be designated pipe culverts, special for fill heights exceeding 15 ft (4.5 m).
b.Extra strength clay pipe will only be permitted for pipe culverts Type 1, for 10 in., 12 in., 42 in. and 48 in. (250 mm, 300 mm, 1050 mm and 1200 mm), Types 2, up to and including 48 in. (1200 mm), Type 3, up to and including 18 in. (450 mm), Type 4 up to and including 10 in. (250 mm), for all pipe classes.
c.Concrete sewer, storm drain, and culvert pipe Class 3 will only be permitted for pipe culverts Type 1, up to and including 10 in. (250 mm), Type 2, up to and including 30 in. (750 mm), Type 3, up to and including 15 in. (375 mm); Type 4, up to and including 10 in. (250 mm), for all pipe classes. Table IA: Classes of Reinforced Concrete Pipe for the Respective Diameters of Pipe and Fill Heights over the Top of the Pipe Nominal Diameter, in. Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 Fill Height: Fill Height: Fill Height: Fill Height: Fill Height: Fill Height: Fill Height: 3' and less 1' min. cover Greater than 3' not exceeding 10' Greater than 10' not exceeding 15' Greater than 15' not exceeding 20' Greater than 20' not exceeding 25' Greater than 25' not exceeding 30' Greater than 30' not exceeding 35' 12 IV II III IV IV V V 15 IV II III IV IV V V 18 IV II III IV IV V V 21 III II III IV IV V V 24 III II III IV IV V V 30 IV II III IV IV V V 36 III II III IV IV V V 42 II II III IV IV V V 48 II II III IV IV V V 54 II II III IV IV V V 60 II II III IV IV V V 66 II II III IV IV V V 72 II II III IV V V V 78 II II III IV 2020 2370 2730 84 II II III IV 2020 2380 2740 90 II II III 1680 2030 2390 2750 96 II III III 1690 2040 2400 2750 102 II III III 1700 2050 2410 2760 108 II III 1360 1710 2060 2410 2770 Notes: A number indicates the D-Load for the diameter and depth of fill and that a special design is required. Design assumptions; Water filled pipe, Type 2 bedding and Class C Walls Art. 542.03 Table IA: Classes of Reinforced Concrete Pipe for the Respective Diameters of Pipe and Fill Heights over the Top of the Pipe (Metric) Nominal Diameter, mm Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 Fill Height: 1 m and less 0.3 m min. cover Fill Height: Greater than 1 m not exceeding 3 m Fill Height: Greater than 3 m not exceeding 4.5 m Fill Height: Greater than 4.5 m not exceeding 6 m Fill Height: Greater than 6 m not exceeding 7.5 m Fill Height: Greater than 7.5 m not exceeding 9 m Fill Height: Greater than 9 m not exceeding 10.5 m 300 IV II III IV IV V V 375 IV II III IV IV V V 450 IV II III IV IV V V 525 III II III IV IV V V 600 III II III IV IV V V 750 IV II III IV IV V V 900 III II III IV IV V V 1050 II II III IV IV V V 1200 II II III IV IV V V 1350 II II III IV IV V V 1500 II II III IV IV V V 1650 II II III IV IV V V 1800 II II III IV V V V 1950 II II III IV 100 110 130 2100 II II III IV 100 110 130 2250 II II III 80 100 110 130 2400 II III III 80 100 110 130 2550 II III III 80 100 120 130 2700 II III 70 80 100 120 130 Notes: A number indicates the D-Load for the diameter and depth of fill and that a special design is required. Design assumptions; Water filled pipe, Type 2 bedding and Class C Walls Art. 542.03 TABLE IB: THICKNESS OF CORRUGATED STEEL PIPE FOR THE RESPECTIVE DIAMETER OF PIPE AND FILL HEIGHTS OVER THE TOP OF THE PIPE FOR 2 2/3"x1/2", 3"x1" AND 5"x1" CORRUGATIONS Nominal Diameter, in.* Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 Fill Height: Fill Height: Fill Height: Fill Height: Fill Height: Fill Height: Fill Height: 3' and less 1' min. cover Greater than 3' not exceeding 10' Greater than 10' not exceeding 15' Greater than 15' not exceeding 20' Greater than 20' not exceeding 25' Greater than 25' not exceeding 30' Greater than 30' not exceeding 35' 2 2/3" x 1/2" 3"x1" 5"x1" 2 2/3" x 1/2" 3"x1" 5"x1" 2 2/3" x 1/2" 3"x1" 5"x1" 2 2/3" x 1/2" 3"x1" 5"x1" 2 2/3" x 1/2" 3"x1" 5"x1" 2 2/3" x 1/2" 3"x1" 5"x1" 2 2/3" x 1/2" 3"x1" 5"x1" 12 0.064 0.064 0.064 0.064 0.064 0.064 0.064 15 0.064 0.064 0.064 0.064 0.064 0.064 (0.079) 18 (0.079) 0.064 0.064 0.064 0.064 (0.079) (0.079) 21 (0.079) 0.064 0.064 0.064 (0.079) (0.079) (0.079) 24 (0.079) 0.064 0.064 0.064 (0.079) (0.079) (0.109) 30 (0.109E) 0.064 0.064 (0.079) (0.079) (0.109) 0.109 36 (0.109E) 0.064 (0.079) (0.079) (0.109) 0.109 (0.138E) 42 0.079 0.064 (0.079) (0.079) (0.109) (0.109E) (0.109E) 48 0.109 (0.109) 0.109 (0.109) 0.079 0.079 (0.109) 0.079 (0.109) 0.109 (0.109) 0.109 (0.138) (0.109) 0.109 (0.138E) 0.109 0.109 (0.138E) 0.109 (0.138) 54 0.109 (0.109) 0.109 (0.109) 0.079 0.079 0.109 (0.109) 0.109 0.109 (0.109) 0.109 (0.138) 0.109 0.109 (0.138E) 0.109 (0.138) (0.138E) 0.138 0.138 60 0.109 0.109 0.109 0.109 0.079 (0.109) 0.109 (0.109) 0.109 0.109 (0.109) 0.109 (0.138) 0.109 0.109 (0.138E) (0.138) (0.138) 0.138E (0.138E) (0.138E) 66 (0.138) 0.109 0.109 0.109 0.079 (0.109) 0.109 (0.109) 0.109 0.109 0.109 0.109 (0.138) 0.109 (0.138) (0.138E) 0.138 0.138 0.138E (0.138E) 0.138E 72 0.138 0.109 (0.138) 0.138 (0.109) (0.109) 0.138 (0.109) 0.109 0.138 0.109 0.109 0.138 (0.138) (0.138) (0.168E) (0.138E) 0.138E (0.168E) (0.138E) 0.138E 78 0.168 0.109 (0.138) 0.168 (0.109) 0.109 0.168 0.109 0.109 0.168 0.109 (0.138) 0.168 (0.138) (0.138) H0.168E (0.138E) 0.138E H0.168E 0.138E (0.168E) 84 0.168 (0.138) (0.138) 0.168 (0.109) 0.109 0.168 0.109 0.109 0.168 0.109 (0.138) 0.168 (0.138) 0.138 H0.168E (0.138E) 0.138E H0.168E (0.168E) (0.168E) 90 (0.138) (0.138) (0.109) 0.109 0.109 0.109 (0.138) (0.138) (0.138) 0.138 0.138E (0.168E) (0.168E) (0.168E) 96 (0.138) (0.138) (0.109) 0.109 0.109 0.109 (0.138) (0.138) (0.138) 0.138 (0.168E) (0.168E) (0.168E) (0.168E) 102 0.109Z 0.109Z (0.109) 0.109 0.109 (0.138) (0.138) (0.138) (0.138) 0.138 (0.168E) (0.168E) H0.138E H0.168E 108 0.109Z (0.138Z) 0.109 0.109 0.109 (0.138) (0.138) 0.138 0.138 (0.168) (0.168E) (0.168E) H0.138E H0.168E 114 0.109Z (0.138Z) 0.109 0.109 0.109 (0.138) (0.138) 0.138 (0.168) (0.168) (0.168E) 0.168E H0.138E H0.168E 120 0.109Z (0.138Z) 0.109 0.109 (0.138) (0.138) (0.138) 0.138 (0.168) (0.168) H0.138E H0.168E H0.168E H0.168E 126 0.138Z 0.138Z 0.138 0.138 0.138 0.138 0.138 (0.168) (0.168) (0.168) H0.138E H0.168E H0.168E H0.168E 132 0.138Z 0.138Z 0.138 0.138 0.138 0.138 (0.168) (0.168) 0.168 0.168 H0.138E H0.168E H0.168E H0.168E 138 0.138Z 0.138Z 0.138 0.138 0.138 0.138 (0.168) (0.168) (0.168E) H0.168E H0.168E H0.168E H0.168E 144 0.168Z 0.168Z 0.168 0.168 0.168 0.168 0.168 0.168 H0.168E H0.168E H0.168E H0.168E H0.168E Notes: * Aluminized Type 2 Steel or Precoated Galvanized Steel shall be required for diameters up to 42” according to Article 1006.01, 1 1/2" x 1/4" corrugations shall be used for diameters less than 12”. E Elongation according to Article 542.04(e) Z 1’-6” Minimum fill H A thickness preceded by “H” indicates only helical seam fabrication is allowed. Thicknesses are based on longitudinal riveted seam fabrication, values in “()” can be reduced by one gage thickness if helical seam fabrication is utilized. Art. 542.03 TABLE IB: THICKNESS OF CORRUGATED STEEL PIPE (Metric) FOR THE RESPECTIVE DIAMETER OF PIPE AND FILL HEIGHTS OVER THE TOP OF THE PIPE FOR 68 mm x 13 mm, 75 mm x 25 mm AND 125 mm x 25 mm CORRUGATIONS Nominal Diameter, mm * Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 Fill Height: Fill Height: Fill Height: Fill Height: Fill Height: Fill Height: Fill Height: 1 m and less 0.3 m min. cover Greater than 1 m not exceeding 3 m Greater than 3 m not exceeding 4.5 m Greater than 4.5 m not exceeding 6 m Greater than 6 m not exceeding 7.5 m Greater than 7.5 m not exceeding 9 m Greater than 9 m not exceeding 10.5 m 68 x 13 mm 75 x 25 mm 125 x 25 mm 68 x 13 mm 75 x 25 mm 125 x 25 mm 68 x 13 mm 75 x 25 mm 125 x 25 mm 68 x 13 mm 75 x 25 mm 125 x 25 mm 68 x 13 mm 75 x 25 mm 125 x 25 mm 68 x 13 mm 75 x 25 mm 125 x 25 mm 68 x 13 mm 75 x 25 mm 125 x 25 mm 300 1.63 1.63 1.63 1.63 1.63 1.63 1.63 375 1.63 1.63 1.63 1.63 1.63 1.63 (2.01) 450 (2.01) 1.63 1.63 1.63 1.63 (2.01) (2.01) 525 (2.01) 1.63 1.63 1.63 (2.01) (2.01) (2.01) 600 (2.01) 1.63 1.63 1.63 (2.01) (2.01) (2.77) 750 (2.77E) 1.63 1.63 (2.01) (2.01) (2.77) 2.77 900 (2.77E) 1.63 (2.01) (2.01) (2.77) 2.77 (3.51E) 1050 2.01 1.63 (2.01) (2.01) (2.77) (2.77E) (2.77E) 1200 2.77 (2.77) 2.77 (2.77) 2.01 2.01 (2.77) 2.01 (2.77) 2.77 (2.77) 2.77 (3.51) (2.77) 2.77 (3.51E) 2.77 2.77 (3.51E) 2.77 (3.51) 1350 2.77 (2.77) 2.77 (2.77) 2.01 2.01 2.77 (2.77) 2.77 2.77 (2.77) 2.77 (3.51) 2.77 2.77 (3.51E) 2.77 (3.51) (3.51E) 3.51 3.51 1500 2.77 2.77 2.77 2.77 2.01 (2.77) 2.77 (2.77) 2.77 2.77 (2.77) 2.77 (3.51) 2.77 2.77 (3.51E) (3.51) (3.51) 3.51E (3.51E) (3.51E) 1650 (3.51) 2.77 2.77 2.77 2.01 (2.77) 2.77 (2.77) 2.77 2.77 2.77 2.77 (3.51) 2.77 (3.51) (3.51E) 3.51 3.51 3.51E (3.51E) 3.51E 1800 3.51 2.77 (3.51) 3.51 (2.77) (2.77) 3.51 (2.77) 2.77 3.51 2.77 2.77 3.51 (3.51) (3.51) (4.27E) (3.51E) 3.51E (4.27E) (3.51E) 3.51E 1950 4.27 2.77 (3.51) 4.27 (2.77) 2.77 4.27 2.77 2.77 4.27 2.77 (3.51) 4.27 (3.51) (3.51) H 4.27E (3.51E) 3.51E H 4.27E 3.51E (4.27E) 2100 4.27 (3.51) (3.51) 4.27 (2.77) 2.77 4.27 2.77 2.77 4.27 2.77 (3.51) 4.27 (3.51) 3.51 H 4.27E (3.51E) 3.51E H 4.27E (4.27E) (4.27E) 2250 (3.51) (3.51) (2.77) 2.77 2.77 2.77 (3.51) (3.51) (3.51) 3.51 3.51E (4.27E) (4.27E) (4.27E) 2400 (3.51) (3.51) (2.77) 2.77 2.77 2.77 (3.51) (3.51) (3.51) 3.51 (4.27E) (4.27E) (4.27E) (4.27E) 2550 2.77Z 2.77Z (2.77) 2.77 2.77 (3.51) (3.51) (3.51) (3.51) 3.51 (4.27E) (4.27E) H 3.51E H 4.27E 2700 2.77Z (3.51Z) 2.77 2.77 2.77 (3.51) (3.51) 3.51 3.51 (4.27) (4.27E) (4.27E) H 3.51E H 4.27E 2850 2.77Z (3.51Z) 2.77 2.77 2.77 (3.51) (3.51) 3.51 (4.27) (4.27) (4.27E) 4.27E H 3.51E H 4.27E 3000 2.77Z (3.51Z) 2.77 2.77 (3.51) (3.51) (3.51) 3.51 (4.27) (4.27) H 3.51E H 4.27E H 4.27E H 4.27E 3150 3.51Z 3.51Z 3.51 3.51 3.51 3.51 3.51 (4.27) (4.27) (4.27) H 3.51E H 4.27E H 4.27E H 4.27E 3300 3.51Z 3.51Z 3.51 3.51 3.51 3.51 (4.27) (4.27) 4.27 4.27 H 3.51E H 4.27E H 4.27E H 4.27E 3450 3.51Z 3.51Z 3.51 3.51 3.51 3.51 (4.27) (4.27) (4.27E) H 4.27E H 4.27E H 4.27E H 4.27E 3600 4.27Z 4.27Z 4.27 4.27 4.27 4.27 4.27 4.27 H 4.27E H 4.27E H 4.27E H 4.27E H 4.27E Notes: * Aluminized Type 2 Steel or Precoated Galvanized Steel shall be required for diameters up to 1050 mm according to Article 1006.01, 38 mm x 6.5 mm corrugations shall be used for diameters less than 300 mm. E Elongation according to Article 542.04(e) Z 450 mm Minimum fill H A thickness preceded by an “H” indicates only helical seam fabrication is allowed. Thicknesses are based on longitudinal riveted seam fabrication, values in “()” can be reduced by one gage thickness if helical seam fabrication is utilized. Art. 542.03 TABLE IC: THICKNESS OF CORRUGATED ALUMINUM ALLOY PIPE FOR THE RESPECTIVE DIAMETER OF PIPE AND FILL HEIGHTS OVER THE TOP OF THE PIPE FOR 2 2/3"x1/2" AND 3"x1" CORRUGATIONS Nominal Diameter, in. Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 Fill Height: Fill Height: Fill Height: Fill Height: Fill Height: Fill Height: Fill Height: 3' and less 1' min. cover Greater than 3' not exceeding 10' Greater than 10' not exceeding 15' Greater than 15' not exceeding 20' Greater than 20' not exceeding 25' Greater than 25' not exceeding 30' Greater than 30' not exceeding 35' 2 2/3" x 1/2" 3"x1" 2 2/3" x 1/2" 3"x1" 2 2/3" x 1/2" 3"x1" 2 2/3" x 1/2" 3"x1" 2 2/3" x 1/2" 3"x1" 2 2/3" x 1/2" 3"x1" 2 2/3" x 1/2" 3"x1" 12 (0.075) 0.060 0.060 0.060 0.060 0.060 0.060 15 (0.075) 0.060 0.060 0.060 0.060 0.060 (0.075) 18 (0.075) 0.060 0.060 0.060 0.060 (0.075) H 0.060 21 H 0.060E 0.060 0.060 0.060 (0.075) H 0.060 H 0.060E 24 (0.105E) 0.060 0.060 (0.075) (0.105) (0.105) (0.105E) 30 H 0.075E H 0.060 0.075 H 0.060 0.075 H 0.060 (0.105) H 0.060 (0.105) H 0.060 H 0.075E H 0.060 H 0.075E H 0.060 36 (0.135E) H 0.060E 0.075 H 0.060 (0.105) H 0.060 (0.105) H 0.060 (0.135) H 0.060 H 0.075E H 0.060 H 0.075E H 0.060E 42 0.105E (0.075) 0.105 0.060 0.105 0.060 0.105 0.060 0.105 (0.075) 0.105E 0.105 0.105E (0.105E) 48 0.105E (0.075) 0.105 0.060 0.105 0.060 0.105 (0.075) 0.105 (0.105) 0.105E (0.105E) 0.105E (0.135E) 54 0.105E (0.105) 0.105 0.060 0.105 0.060 0.105 (0.075) 0.105 (0.105) 0.105E (0.105E) (0.135E) (0.135E) 60 0.135E (0.105) 0.135 0.060 0.135 (0.075) 0.135 (0.105) 0.135 (0.105) 0.135E (0.135E) (0.164E) (0.135E) 66 0.164E (0.105) 0.164 0.060 0.164 (0.075) 0.164 (0.105) 0.164 (0.135) 0.164E (0.135E) H 0.164E (0.135E) 72 0.164E (0.105) 0.164 0.060 0.164 (0.075) 0.164 (0.105) 0.164 (0.135) H 0.164E (0.135E) H 0.164E (0.164E) 78 (0.135) 0.075 (0.105) (0.105) (0.135) (0.135E) (0.164E) 84 (0.135) 0.105 0.105 (0.135) (0.135) (0.164E) (0.164E) 90 (0.135) 0.105 0.105 (0.135) (0.135) (0.164E) (0.164E) 96 (0.135) 0.105 0.105 (0.135) (0.135) (0.164E) H 0.135E 102 0.135Z 0.135 0.135 0.135 (0.164) (0.164E) H 0.135E 108 0.135Z 0.135 0.135 0.135 (0.164) (0.164E) H 0.164E 114 0.164Z 0.164 0.164 0.164 0.164 H 0.164E H 0.164E 120 0.164Z 0.164 0.164 0.164 0.164 H 0.164E Notes: E Elongation according to Article 542.04(e), the elongation requirement for Type 1 fill heights may be eliminated for fills above 1' -6" Z 1”-6” Minimum fill H A thickness preceded by an “H” indicates only helical seam fabrication is allowed. Thicknesses are based on longitudinal riveted seam fabrication, values in “()” can be reduced by one gage thickness if helical seam fabrication is utilized. Art. 542.03 TABLE IC: THICKNESS OF CORRUGATED ALUMINUM ALLOY PIPE FOR THE RESPECTIVE DIAMETER OF PIPE AND FILL HEIGHTS OVER THE TOP OF THE PIPE FOR 68 mm x 13 mm AND 75 mm x 25 mm CORRUGATIONS (Metric) Nominal Diameter, mm Type 1 Type 2 Type 3 Type 4 Type 5 Type 6 Type 7 Fill Height: Fill Height: Fill Height: Fill Height: Fill Height: Fill Height: Fill Height: 1 m and less 0.3 m min. cover Greater than 1 m not exceeding 3 m Greater than 3 m not exceeding 4.5 m Greater than 4.5 m not exceeding 6 m Greater than 6 m not exceeding 7.5 m Greater than 7.5 m not exceeding 9 m Greater than 9 m not exceeding 10.5 m 68 x 13 mm 75 x 25 mm 68 x 13 mm 75 x 25 mm 68 x 13 mm 75 x 25 mm 68 x 13 mm 75 x 25 mm 68 x 13 mm 75 x 25 mm 68 x 13 mm 75 x 25 mm 68 x 13 mm 75 x 25 mm 300 (1.91) 1.52 1.52 1.52 1.52 1.52 1.52 375 (1.91) 1.52 1.52 1.52 1.52 1.52 (1.91) 450 (1.91) 1.52 1.52 1.52 1.52 (1.91) H 1.52 525 H 1.52E 1.52 1.52 1.52 (1.91) H 1.52 H 1.52E 600 (2.67E) 1.52 1.52 (1.91) (2.67) (2.67) (2.67E) 750 H 1.91E H 1.52 1.91 H 1.52 1.91 H 1.52 (2.67) H 1.52 (2.67) H 1.52 H 1.91E H 1.52 H 1.91E H 1.52 900 (3.43E) H 1.52E 1.91 H 1.52 (2.67) H 1.52 (2.67) H 1.52 (3.43) H 1.52 H 1.91E H 1.52 H 1.91E H 1.52E 1050 2.67E (1.91) 2.67 1.52 2.67 1.52 2.67 1.52 2.67 (1.91) 2.67E 2.67 2.67E (2.67E) 1200 2.67E (1.91) 2.67 1.52 2.67 1.52 2.67 (1.91) 2.67 (2.67) 2.67E (2.67E) 2.67E (3.43E) 1350 2.67E (2.67) 2.67 1.52 2.67 1.52 2.67 (1.91) 2.67 (2.67) 2.67E (2.67E) (3.43E) (3.43E) 1500 3.43E (2.67) 3.43 1.52 3.43 (1.91) 3.43 (2.67) 3.43 (2.67) 3.43E (3.43E) (4.17E) (3.43E) 1650 4.17E (2.67) 4.17 1.52 4.17 (1.91) 4.17 (2.67) 4.17 (3.43) 4.17E (3.43E) H 4.17E (3.43E) 1800 4.17E (2.67) 4.17 1.52 4.17 (1.91) 4.17 (2.67) 4.17 (3.43) H 4.17E (3.43E) H 4.17E (4.17E) 1950 (3.43) 1.91 (2.67) (2.67) (3.43) (3.43E) (4.17E) 2100 (3.43) 2.67 2.67 (3.43) (3.43) (4.17E) (4.17E) 2250 (3.43) 2.67 2.67 (3.43) (3.43) (4.17E) (4.17E) 2400 (3.43) 2.67 2.67 (3.43) (3.43) (4.17E) H 3.43E 2550 3.43Z 3.43 3.43 3.43 (4.17) (4.17E) H 3.43E 2700 3.43Z 3.43 3.43 3.43 (4.17) (4.17E) H 4.17E 2850 4.17Z 4.17 4.17 4.17 4.17 H 4.17E H 4.17E 3000 4.17Z 4.17 4.17 4.17 4.17 H 4.17E Notes: E Elongation according to Article 542.04(e), the elongation requirement for Type 1 fill heig hts may be eliminated for fills above 450 mm. Z 450 mm Minimum fill H A thickness preceded by an “H” indicates only helical seam fabrication is allowed. Thicknesses are based on longitudinal riveted seam fabrication, values in “()” can be reduced by one ga ge thickness if helical seam fabrication is utilized. Art. 542.03 Table IIA: THICKNESS FOR CORRUGATED STEEL PIPE ARCHES AND CORRUGATED ALUMINUM ALLOY PIPE ARCHES FOR THE RESPECTIVE EQUIVALENT ROUND SIZE OF PIPE AND FILL HEIGHTS OVER THE TOP OF PIPE Equivalent Round Size, in. Corrugated Steel & Aluminum Pipe Arch 2 2/3"x1/2" Corrugated Steel & Aluminum Pipe Arch 3" x 1" Corrugated Steel Pipe Arch 5" x 1" Min. Cover Type 1 Type 2 Type 3 Fill Height: Fill Height: Fill Height: 3' and less Greater than 3', not exceeding 10' Greater than 10', not exceeding 15' Span (in.)* Rise (in.) Span (in.) Rise (in.) Span (in.) Rise (in.) Steel & Aluminum Steel Aluminum Steel Aluminum Steel Aluminum 2 2/3" x 1/2" 3"x1" 5" x 1" 2 2/3" x 1/2" 3"x1" 2 2/3" x 1/2" 3"x1" 5" x 1" 2 2/3" x 1/2" 3"x1" 2 2/3" x 1/2" 3"x1" 5" x 1" 2 2/3" x 1/2" 3"x1" 15 17 13 1'-6" 0.064 0.060 0.064 0.060 0.064 0.060 18 21 15 1'-6" 0.064 0.060 0.064 0.060 0.064 0.060 21 24 18 1'-6" 0.064 (0.075) 0.064 0.060 0.064 0.060 24 28 20 1'-6" (0.079) (0.105) 0.064 0.075 0.064 0.075 30 35 24 1'-6" (0.079) (0.105) 0.064 0.075 (0.079) (0.105) 36 42 29 1'-6" (0.079) 0.105 0.064 0.105 0.064 0.105 42 49 33 1'-6" 0.109 0.105 (0.109) 0.105 (0.109) 0.105 48 57 38 53 41 53 41 1'-6" 0.109 (0.109) (0.109) 0.135 0.060 0.109 0.079 0.079 0.135 0.060 0.109 0.079 (0.109) 0.135 0.060 54 64 43 60 46 60 46 1'-6" 0.109 (0.109) 0.109 0.164 (0.075) 0.109 0.079 0.079 0.164 0.060 0.109 (0.109) 0.109 0.164 (0.075) 60 71 47 66 51 66 51 1'-6" 0.138 (0.109) 0.109 0.164 (0.075) 0.138 0.079 (0.109) 0.164 0.060 0.138 (0.109) 0.109 0.164 (0.075) 66 77 52 73 55 73 55 1'-6" 0.168 (0.109) 0.109 0.075 0.168 0.079 (0.109) 0.075 0.168 (0.109) 0.109 0.075 72 83 57 81 59 81 59 1'-6" 0.168 (0.109) 0.109 0.105 0.168 0.079 (0.109) 0.105 0.168 (0.109) 0.109 0.105 78 87 63 87 63 1'-6" 0.109 0.109 0.105 (0.109) 0.109 0.105 0.109 0.109 0.105 84 95 67 95 67 1'-6" 0.109 0.109 0.105 (0.109) 0.109 0.105 0.109 0.109 0.105 90 103 71 103 71 1'-6" 0.109 0.109 0.135 (0.109) 0.109 0.135 0.109 0.109 0.135 96 112 75 112 75 1'-6" 0.109 (0.138) 0.164 0.109 0.109 0.164 0.109 (0.138) 0.164 102 117 79 117 79 1'-6" 0.109 (0.138) 0.164 0.109 0.109 0.164 0.109 (0.138) 0.164 108 128 83 128 83 1'-6" 0.138 0.138 0.138 0.138 0.138 0.138 114 137 87 137 87 1'-6" 0.138 0.138 0.138 0.138 0.138 0.138 120 142 91 142 91 1'-6" 0.168 0.168 0.168 0.168 0.168 0.168 Notes: * Aluminized Type 2 Steel or Precoated Galvanized Steel shall be required for steel spans up to 42” ac cording to Article 1006.01. Thicknesses are based on longitudinal riveted seam fabrication, values in “()” can be reduced by one gage thickness if helica l seam fabrication is utilized. The Type 1 corrugated steel or aluminum pipe arches shall be placed on soil having a minimum bearing capacity of 3 tons per square foot. The Type 2 and 3 corrugated steel or aluminum pipe arches shall be placed on soil having a minimum bearing capacity of 2 tons per square foot. This minimum bearing capacity will be determined by the Engineer in the field. Art. 542.03 Table IIA: THICKNESS FOR CORRUGATED STEEL PIPE ARCHES AND CORRUGATED ALUMINUM ALLOY PIPE ARCHES FOR THE RESPECTIVE EQUIVALENT ROUND SIZE OF PIPE AND FILL HEIGHTS OVER THE TOP OF PIPE (Metric) Equivalent Round Size (mm) Corrugate d Steel & Aluminum Pipe Arch 68 x 13 mm Corrugated Steel & Aluminum Pipe Arch 75 x 25 mm Corrugated Steel Pipe Arch 125 x 25 mm Min. Cover Type 1 Type 2 Type 3 Fill Height: Fill Height: Fill Height: 1 m and less Greater than 1 m, not exceeding 3 m Greater than 3 m, not exceeding 4.5 m Span (mm)* Rise (mm) Span (mm) Rise (mm) Span (mm) Rise (mm) Steel & Aluminum Steel Aluminum Steel Aluminum Steel Aluminum 68 x 13 mm 75 x 25 mm 125 x 25 mm 68 x 13 mm 75 x 25 mm 68 x 13 mm 75 x 25 mm 125 x 25 mm 68 x 13 mm 75 x 25 mm 68 x 13 mm 75 x 25 mm 125 x 25 mm 68 x 13 mm 75 x 25 mm 375 430 330 0.5 m 1.63 1.52 1.63 1.52 1.63 1.52 450 530 380 0.5 m 1.63 1.52 1.63 1.52 1.63 1.52 525 610 460 0.5 m 1.63 (1.91) 1.63 1.52 1.63 1.52 600 710 510 0.5 m (2.01) (2.67) 1.63 1.91 1.63 1.91 750 870 630 0.5 m (2.01) (2.67) 1.63 1.91 (2.01) (2.67) 900 1060 740 0.5 m (2.01) 2.67 1.63 2.67 1.63 2.67 1050 1240 840 0.5 m 2.77 2.67 (2.77) 2.67 (2.77) 2.67 1200 1440 970 1340 1050 1340 1050 0.5 m 2.77 (2.77) (2.77) 3.43 1.52 2.77 2.01 2.01 3.43 1.52 2.77 2.01 (2.77) 3.43 1.52 1350 1620 1100 1520 1170 1520 1170 0.5 m 2.77 (2.77) 2.77 4.17 (1.91) 2.77 2.01 2.01 4.17 1.52 2.77 (2.77) 2.77 4.17 (1.91) 1500 1800 1200 1670 1300 1670 1300 0.5 m 3.51 (2.77) 2.77 4.17 (1.91) 3.51 2.01 (2.77) 4.17 1.52 3.51 (2.77) 2.77 4.17 (1.91) 1650 1950 1320 1850 1400 1850 1400 0.5 m 4.27 (2.77) 2.77 1.91 4.27 2.01 (2.77) 1.91 4.27 (2.77) 2.77 1.91 1800 2100 1450 2050 1500 2050 1500 0.5 m 4.27 (2.77) 2.77 2.67 4.27 2.01 (2.77) 2.67 4.27 (2.77) 2.77 2.67 1950 2200 1620 2200 1620 0.5 m 2.77 2.77 2.67 (2.77) 2.77 2.67 2.77 2.77 2.67 2100 2400 1720 2400 1720 0.5 m 2.77 2.77 2.67 (2.77) 2.77 2.67 2.77 2.77 2.67 2250 2600 1820 2600 1820 0.5 m 2.77 2.77 3.43 (2.77) 2.77 3.43 2.77 2.77 3.43 2400 2840 1920 2840 1920 0.5 m 2.77 (3.51) 4.17 2.77 2.77 4.17 2.77 (3.51) 4.17 2550 2970 2020 2970 2020 0.5 m 2.77 (3.51) 4.17 2.77 2.77 4.17 2.77 (3.51) 4.17 2700 3240 2120 3240 2120 0.5 m 3.51 3.51 3.51 3.51 3.51 3.51 2850 3470 2220 3470 2220 0.5 m 3.51 3.51 3.51 3.51 3.51 3.51 3000 3600 2320 3600 2320 0.5 m 4.27 4.27 4.27 4.27 4.27 4.27 Notes: * Aluminized Type 2 Steel or Precoated Galvanized Steel shall be required for steel spans up to 1060 mm according to Article 10 06.01. Thicknesses are based on longitudinal riveted seam fabrication, values in “()” can be reduc ed by one gage thickness if helical seam fabrication is utilized. The Type 1 corrugated steel or aluminum pipe arches shall be placed on soil having a minimum bearing capacity of 290 kN per s quare meter. The Type 2 and 3 corrugated steel or aluminum pipe a rches shall be placed on soil having a minimum bearing capacity of 192 kN per square meter. This minimum bearing capacity will be determined by the Engineer in the field. Art. 542.03 Table IIB: CLASSES OF REINFORCED CONCRETE ELLIPTICALL AND REINFORCED CONCRETE ARCH PIPE FOR THE RESPECTIVE EQUIVALENT ROUND SIZE OF PIPE AND FILL HEIGHTS OVER THE TOP OF PIPE Equivalent Round Size (in.) Reinforced Concrete Elliptical Pipe (in.) Reinforced Concrete Arch Pipe (in.) Minimum Cover Type 1 Type 2 Type 3 Fill Height: 3' and less Fill Height: Greater than 3' not exceeding 10' Fill Height: Greater than 10' not exceeding 15' Span Rise Span Rise RCCP HE & A HE Arch HE Arch HE Arch 15 23 14 18 11 1' -0" HE-III A-III HE-III A-III HE-IV A-IV 18 23 14 22 13 1/2 1' -0" HE-III A-III HE-III A-III HE-IV A-IV 21 30 19 26 15 1/2 1' -0" HE-III A-III HE-III A-III HE-IV A-IV 24 30 19 28 1/2 18 1' -0" HE-III A-III HE-III A-III HE-IV A-IV 27 34 22 36 1/4 22 1/2 1' -0" HE-III A-III HE-III A-III HE-IV A-IV 30 38 24 36 1/4 22 1/2 1' -0" HE-III A-III HE-III A-III HE-IV A-IV 36 45 29 43 3/4 26 5/8 1' -0" HE-II A-II HE-III A-III HE-IV A-IV 42 53 34 51 1/8 31 5/16 1' -0" HE-I A-II HE-III A-III HE-IV A-IV 48 60 38 58 1/2 36 1' -0" HE-I A-II HE-III A-III 1460 1450 54 68 43 65 40 1' -0" HE-I A-II HE-III A-III 1460 1460 60 76 48 73 45 1' -0" HE-I A-II HE-III A-III 1460 1470 66 83 53 88 54 1' -0" HE-I A-II HE-III A-III 1470 1480 72 91 58 88 54 1' -0" HE-I A-II HE-III A-III 1470 1480 Notes: A number indicates the D-Load for the diameter and depth of fill and that a special design is required. Design assumptions; Water filled pipe, AASHTO Type 2 installation per AASHTO LRFD Table 12.10.2.1-1 Art. 542.03 Table IIB: CLASSES OF REINFORCED CONCRETE ELLIPTICALL AND REINFORCED CONCRETE ARCH PIPE FOR THE RESPECTIVE EQUIVALENT ROUND SIZE OF PIPE AND FILL HEIGHTS OVER THE TOP OF PIPE (Metric) Equivalent Round Size (mm) Reinforced Concrete Elliptical pipe (mm) Reinforced Concrete Arch pipe (mm) Minimum Cover Type 1 Type 2 Type 3 Fill Height: 1 m and less Fill Height: Greater than 1 m not exceeding 3 m Fill Height: Greater than 3 m not exceeding 4.5 m Span Rise Span Rise RCCP HE & A HE Arch HE Arch HE Arch 375 584 356 457 279 0.3 m HE-III A-III HE-III A-III HE-IV A-IV 450 584 356 559 343 0.3 m HE-III A-III HE-III A-III HE-IV A-IV 525 762 483 660 394 0.3 m HE-III A-III HE-III A-III HE-IV A-IV 600 762 483 724 457 0.3 m HE-III A-III HE-III A-III HE-IV A-IV 686 864 559 921 572 0.3 m HE-III A-III HE-III A-III HE-IV A-IV 750 965 610 921 572 0.3 m HE-III A-III HE-III A-III HE-IV A-IV 900 1143 737 1111 676 0.3 m HE-II A-II HE-III A-III HE-IV A-IV 1050 1346 864 1299 795 0.3 m HE-I A-II HE-III A-III HE-IV A-IV 1200 1524 965 1486 914 0.3 m HE-I A-II HE-III A-III 70 70 1350 1727 1092 1651 1016 0.3 m HE-I A-II HE-III A-III 70 70 1500 1930 1219 1854 1143 0.3 m HE-I A-II HE-III A-III 70 70 1676 2108 1346 2235 1372 0.3 m HE-I A-II HE-III A-III 70 70 1800 2311 1473 2235 1372 0.3 m HE-I A-II HE-III A-III 70 70 Notes: A number indicates the D-Load for the diameter and depth of fill and that a special design is required. Design assumptions; Water filled pipe, AASHTO Type 2 installation per AASHTO LRFD Table 12.10.2.1-1 Art. 542.03 TABLE IIIA: PLASTIC PIPE PERMITTED FOR A GIVEN PIPE DIAMETER AND FILL HEIGHT OVER THE TOP OF THE PIPE Nominal Diameter (in.) Type 1 Type 2 Type 3 Type 4 Fill Height: 3' and less, with 1' min. cover Fill Height: Greater than 3', not exceeding 10' Fill Height: Greater than 10', not exceeding 15' Fill Height: Greater than 15', not exceeding 20' PVC CPVC PE CPE CPP PVC CPVC PE CPE CPP PVC CPVC PE CPE CPP PVC CPVC PE CPP 10 X X X X NA X X X X NA X X X X NA X X X NA 12 X X X X X X X X X X X X X X X X X X X 15 X X NA X X X X NA X X X X NA X X X X NA X 18 X X X X X X X X X X X X X X X X X X X 21 X X NA NA X X X NA NA X X X NA NA X X X NA X 24 X X X X X X X X X X X X NA X X X X X X 30 X X X X X X X X X X X X X NA X X X X X 36 X X X X X X X X X X X X X NA X X X X NA 42 X NA X X X X NA X X X X NA X NA X X NA X NA 48 X NA X X X X NA X X X X NA X NA X X NA X NA Notes: PVC Polyvinyl Chloride (PVC) pipe with a smooth interior CPVC Corrugated Polyvinyl Chloride (CPVC) pipe with a smooth interior PE Polyethylene (PE) pipe with a smooth interior CPE Corrugated Polyethylene (PE) pipe with a smooth interior CPP Corrugated Polypropylene (CPP) pipe with a smooth interior X This material may be used for the given pipe diameter and fill height NA Not Available Art. 542.03 TABLE IIIA: PLASTIC PIPE PERMITTED FOR A GIVEN PIPE DIAMETER AND FILL HEIGHT OVER THE TOP OF THE PIPE (Metric) Nominal Diameter (mm) Type 1 Type 2 Type 3 Type 4 Fill Height: 1 m and less, with 0.3 m min. cover Fill Height: Greater than 1 m, not exceeding 3 m Fill Height: Greater than 3 m, not exceeding 4.5 m Fill Height: Greater than 4.5 m, not exceeding 6 m PVC CPVC PE CPE CPP PVC CPVC PE CPE CPP PVC CPVC PE CPE CPP PVC CPVC PE CPP 250 X X X X NA X X X X NA X X X X NA X X X NA 300 X X X X X X X X X X X X X X X X X X NA 375 X X NA X X X X NA X X X X NA X X X X NA X 450 X X X X X X X X X X X X X X X X X X X 525 X X NA NA X X X NA NA X X X NA NA X X X NA X 600 X X X X X X X X X X X X NA X X X X X X 750 X X X X X X X X X X X X X NA X X X X X 900 X X X X X X X X X X X X X NA X X X X NA 1000 X NA X X X X NA X X X X NA X NA X X NA X NA 1200 X NA X X X X NA X X X X NA X NA X X NA X NA Notes: PVC Polyvinyl Chloride (PVC) pipe with a smooth interior CPVC Corrugated Polyvinyl Chloride (CPVC) pipe with a smooth interior PE Polyethylene (PE) pipe with a smooth interior CPE Corrugated Polyethylene (PE) pipe with a smooth interior CPP Corrugated Polypropylene (CPP) pipe with a smooth interior X This material may be used for the given pipe diameter and fill height NA Not Available Art. 542.03 TABLE IIIB: PLASTIC PIPE PERMITTED FOR A GIVEN PIPE DIAMETER AND FILL HEIGHT OVER THE TOP OF THE PIPE Nominal Diameter (in.) Type 5 Type 6 Type 7 Fill Height: Greater than 20', not exceeding 25' Fill Height: Greater than 25', not exceeding 30' Fill Height: Greater than 30', not exceeding 35' PVC CPVC CPP PVC CPVC CPVC 10 X X NA X X X 12 X X X X X X 15 X X X X X X 18 X X NA X X X 21 X X X X X X 24 X X NA X X X 30 X X NA X X X 36 X X NA X X X 42 X NA NA X NA NA 48 X NA NA X NA NA Notes: PVC Polyvinyl Chloride (PVC) pipe with a smooth interior CPVC Corrugated Polyvinyl Chloride (CPVC) pipe with a smooth interior CPP Corrugated Polypropylene (CPP) pipe with smooth interior X This material may be used for the given pipe diameter and fill height NA Not Available Art. 542.03 TABLE IIIB: PLASTIC PIPE PERMITTED FOR A GIVEN PIPE DIAMETER AND FILL HEIGHT OVER THE TOP OF THE PIPE (metric) Nominal Diameter (mm) Type 5 Type 6 Type 7 Fill Height: Greater than 6 m, not exceeding 7.5 m Fill Height: Greater than 7.5 m, not exceeding 9 m Fill Height: Greater than 9 m, not exceeding 10.5 m PVC CPVC CPP PVC CPVC CPVC 250 X X NA X X X 300 X X X X X X 375 X X X X X X 450 X X NA X X X 525 X X X X X X 600 X X NA X X X 750 X X NA X X X 900 X X NA X X X 1000 X NA NA X NA NA 1200 X NA NA X NA NA Notes: PVC Polyvinyl Chloride (PVC) pipe with a smooth interior CPVC Corrugated Polyvinyl Chloride (CPVC) pipe with a smooth interior CPP Corrugated Polypropylene (CPP) pipe with a smooth interior X This material may be used for the given pipe diameter and fill height NA Not Available Art. 542.03 A rt. 542.04 Pipe Culverts .04 Method I Construction. Unless otherwise permitted in writing by the Engineer because of conditions encountered in construction, all pipe culverts, except entrance culverts, shall be constructed according to the following. a.Removal and Replacement of Unstable or Unsuitable Material or Rock. Where unstable material such as soft or spongy soil, unsuitable material, or rock in either ledge or boulder formation is encountered at locations along the line of the pipe culvert and at the grade established for the culvert, the material or rock shall be removed and replaced before proceeding with the construction. The unstable and unsuitable material shall be removed to a depth determined by the Engineer and for a width of one diameter (or equivalent diameter) of the pipe on each side of the pipe culvert, and replaced with aggregate. Rock shall be removed to an elevation 1 ft (300 mm) lower than the bottom of the pipe or to a depth equal to 1/2 in./ft (40 mm/m) of ultimate fill height over the top of the pipe culvert, whichever is the greater depth, and for a width as specified in (b) below, and replaced with aggregate. Replacement material shall be placed in 8 in. (200 mm) lifts, loose measurement, and compacted by mechanical means to the satisfaction of the Engineer.
b.Trenching. Pipe culverts shall be constructed in trenches free of water, excavated either in embankments or natural ground. Water shall be removed by use of a diversion channel or by other methods approved by the Engineer. When all or a portion of a pipe will be in fill, the embankment, or a portion thereof, shall be constructed prior to excavating the trench. The embankment shall be constructed to a height which will provide approximately 1 ft (300 mm) of cover over the pipe, except that in no case shall the height of the embankment constructed result in a finished trench depth exceeding 5 ft (1.5 m). The width of the top of the embankment shall be a minimum of 13 ft (4 m) on each side of the pipe culvert, measured at right angles to its centerline, and the longitudinal slopes shall be 1:6 (V:H) or flatter. The embankment shall be constructed according to the requirements of Section 205, except the material shall be select material from excavation or borrow, meeting the approval of the Engineer. Trenches shall be excavated to an elevation 4 in. (100 mm) below the bottom of the pipe and to the following widths. Inside Diameter or Equivalent Diameter of Pipe Required Trench Width On Each Side of the Pipe 24 in. (600 mm) and less 9 in. (225 mm) Greater than 24 in. (600 mm) up to 48 in. (1.2 m) 12 in. (300 mm) Greater than 48 in. (1.2 m) 18 in. (450 mm) Pipe Culverts Art. 542.04 The faces of the excavated trench shall be vertical. If the width of the trench at the top exceeds the maximum horizontal dimension of the pipe by more than the above specified widths as a result of careless or faulty construction methods, that portion of the trench shall be corrected by backfilling in 8 in. (200 mm) lifts and again excavating the trench to the required width. c.Preparation of Foundation. Compacted aggregate, at least 4 in. (100 mm) in depth below the pipe culvert, shall be placed the entire width of the trench and for the length of the pipe culvert, except compacted impervious material shall be used for the outer 3 ft (1 m) at each end of the pipe culvert. When the trench has been widened by the removal and replacement of unstable or unsuitable material, the foundation material shall be placed for a width not less than the above specified widths on each side of the pipe culvert. The aggregate and impervious material shall be compacted by mechanical means to the satisfaction of the Engineer. When pipe having bells or hubs is used, cross trenches not more than 2 in. (50 mm) wider than the bell or hub shall be excavated to provide uniform bearing along the length of the pipe.
d.Laying Pipe. No pipe culvert shall be placed until the trench and the prepared foundation have been approved by the Engineer. The pipe shall be laid so that the flow line of the finished culvert will be at the grade shown on the plans or established by the Engineer. Laying of pipes shall commence at the outlet end, with the spigot ends of the pipe pointing in the direction of the flow, and proceed toward the inlet end with pipes abutting. The ends of the pipe shall be carefully cleaned before the pipes are placed and the pipes shall be placed to avoid unnecessary handling on the foundation. As each length of the pipe is laid, the ends of the pipe shall be protected to prevent the entrance of any material. The pipes shall be fitted and matched so that when laid in the work, they will form a culvert with a smooth, uniform invert. All joints in concrete culverts shall be sealed with rubber gaskets, preformed flexible joint sealants, mastic joint sealer, or external sealing bands. When mastic joint sealer is used, the material shall completely fill the joint after the pipes have been brought together. After each joint is sealed, it shall be wiped clean on the inside. Each section of pipe shall be pushed or pulled to the section in place to ensure tight joints. Pipe having a diameter or equivalent diameter greater than 42 in. (1 m) shall be set or "brought home" with a winch, come-a-long, or other positive means. Handling holes in concrete pipe shall be filled with a precast concrete plug and sealed with mastic or mortar; or filled with a polyethylene plug. The plug shall not project beyond the inside surface after installation. When corrugated steel or aluminum alloy culvert pipe (including bituminous coated steel or aluminum and precoated steel) is used, the pipe shall be placed such that the longitudinal lap is placed at the sides and separate A rt. 542.04 Pipe Culverts sections of pipe shall be joined with a hugger-type band. When the pipes are fabricated with a smooth sleeve-type coupler, the gasket material shall be according to Article 1006.01. PVC, PE, and CPP pipes shall be joined according to the manufacturer’s specifications. e.Elongation. Circular corrugated steel or aluminum alloy culvert pipe (including bituminous coated steel or aluminum and precoated steel) that are specified as elongated in Table IB or IC shall be elongated vertically 5 percent ± 0.75 percent out of a round before any fill is placed. The pipe, except for bituminous coated corrugated steel or aluminum culvert pipe, shall be elongated by one of the following methods.
1.Deformation during fabrication.
2.Elongation by the use of wires, rods, or straps during fabrication.
3.Elongation at the time of installation by the use of vertical struts, wedged or jacked inside the pipe in a manner approved by the Engineer. Bituminous coated corrugated steel or aluminum culvert pipe shall be elongated by either method (1) or (2) prior to coating. Pipe elongated by the manufacturer shall be marked to show the top. The pipe shall be stored, transported, and handled in such a manner so that at the time of installation the pipe shall have retained its elongation. When the pipe is elongated by method (2) or (3), it shall be installed in a manner that will permit the gradual reduction of elongation as the fill over the pipe is placed. This reduction in elongation shall be as directed by the Engineer and may be accomplished by the use of softwood compression caps when struts or jacks are used, or by the use of turnbuckles or other devices when wires, rods, or straps are used. After the fill has been placed and compacted, all struts, wires, rods, or straps shall be removed and any holes in the pipe resulting from their use shall be plugged in a manner satisfactory to the Engineer. Heavy asphaltic or tar material, or other material, or a device meeting the approval of the Engineer may be used to plug the holes. No strutting or elongation will be permitted on corrugated steel or aluminum (including bituminous coated steel or aluminum and precoated steel) pipe arches.
f.Backfilling. As soon as the condition of the pipe culvert will permit, the entire width of the trench shall be backfilled with aggregate to a height of at least the center of the pipe. The aggregate shall be placed longitudinally along the pipe culvert, except at the outer 3 ft (1 m) at each end of the culvert which shall be backfilled with impervious material. The elevation of the backfill material on each side of the pipe shall be the same. The space Pipe Culverts Art. 542.04 under the pipe shall be completely filled. The aggregate and impervious material shall be placed in lifts not exceeding 8 in. (200 mm) in depth, loose measurement, and compacted by mechanical means to the satisfaction of the Engineer. When using flexible pipe, as listed in the first table of Article 542.03, the aggregate shall be continued to a height of at least 1 ft (300 mm) above the top of the pipe and compacted to a minimum of 95 percent of standard lab density by mechanical means. The installed pipe and its embedment shall not be disturbed when using movable trench boxes and shields, sheet pile, or other trench protection. The remainder of the trench shall be backfilled as follows.
1.Trench Backfill. For trenches made in the subgrade of the proposed improvement, and trenches where the inner edge of the trench is within 2 ft (600 mm) of the proposed edge of pavement, curb, gutter, curb and gutter, stabilized shoulder, or sidewalk, the remainder of the trench shall be backfilled with trench backfill material meeting the requirements of Section 208. The material shall be placed in lifts not exceeding 8 in. (200 mm) in depth, loose measurement, and compacted to a minimum of 85 percent of standard lab density by mechanical means. 2.Select Material. For all other trenches, the remainder of the trench shall be backfilled with select material. The select material shall be from excavation or borrow, free from large or frozen lumps, clods, or rock, meeting the approval of the Engineer. The material shall be placed in lifts not exceeding 8 in. (200 mm) in depth, loose measurement, and compacted to 95 percent of standard lab density by mechanical means. Before compaction, each lift shall be wetted or dried to bring the moisture content within 80 to 110 percent of optimum as determined according to Illinois Modified AASHTO T 99 (Method C). The Contractor may, at no additional cost to the Department, backfill the remainder of the trench with aggregate in lieu of select material. The aggregate shall be placed in lifts not exceeding 8 in. (200 mm) in depth, loose measurement and compacted by mechanical means to the satisfaction of the Engineer. The outer 3 ft (1 m) at each end of all trenches shall be backfilled with impervious material. The material shall be placed in lifts not exceeding 8 in. (200 mm) in depth, loose measurement and compacted to 95 percent of standard lab density by mechanical means. In lieu of trench backfill or select material, the Contractor may, at no additional cost to the Department, backfill the entire trench, excepting the outer 3 ft (1 m), with controlled low-strength material according to Section 593. Art. 542.04 Pipe Culverts All backfill material shall be placed in such a manner as not to damage the culvert. The filling of the trench shall be carried on simultaneously on both sides of the pipe. When the trench has been widened for the removal and replacement of unstable or unsuitable material, the backfilling with aggregate and impervious material, will be required for a width of at least the specified widths on each side of the pipe. The remaining width of each lift may be backfilled with select material. Each 8 in. (200 mm) lift for the entire trench width shall be completed before beginning the placement of the next lift. g.Embankment. When the top of the completed backfill is less than 1 ft (300 mm) above the top of the pipe, embankment shall be constructed to an elevation of 1 ft (300 mm) over the top of the pipe. The width and longitudinal slopes of the embankment shall be as specified in
The embankment shall be constructed according to Section 205, except the material shall be select material, from excavation or borrow, meeting the approval of the Engineer. While constructing the embankment, no loads, other than the equipment permitted by the Engineer for the construction of the embankment, shall be introduced upon the pipe culvert and no heavy earth-moving equipment will be permitted within 4 ft (1.2 m) of either side of the pipe culvert.
h.Additional Embankment. After the trench has been backfilled and embankment constructed to an elevation of 1 ft (300 mm) over the top of the pipe culvert, additional embankment shall be constructed before the Contractor will be permitted to introduce any loads upon the pipe culvert. The required cover, including any embankment cover over the pipe and additional embankment, shall be sufficient for the maximum load, including the weight of equipment, which the Contractor proposes to operate or move across the pipe culvert. The total cover required for various construction loadings shall be the responsibility of the Contractor. Additional embankment shall be constructed according to Section 205. Its width on each side of the pipe culvert shall be 13 ft (4 m) and the longitudinal slopes shall not be steeper than 1:6 (V:H). The width of the additional embankment, measured along the pipe culvert, shall be the actual fill width indicated on the cross sections at the elevation required per the Contractor’s design or sufficient to accommodate two-way traffic of the Contractor’s grading operations and so no equipment is operated within 10 ft (3 m) of either shoulder line, whichever is the least. Where the elevation of the additional embankment is above the elevation of the finished embankment, the Contractor shall remove it at the time of final grading operations. Where the elevation of the finished embankment is higher than the additional embankment, the Contractor shall scarify the surface of the slopes and the top of the embankment. Pipe Culverts Art. 542.05 i.Deflection Testing for Pipe Culverts. All PE, PVC, and CPP pipe culverts shall be tested for deflection not less than 30 days after the pipe is installed and the backfill compacted. The testing shall be performed in the presence of the Engineer. For PVC, PE, and CPP pipe culverts with diameters 24 in. (600 mm) or smaller, a mandrel drag shall be used for deflection testing. For PVC, PE, and CPP pipe culverts with diameters over 24 in. (600 mm), deflection measurements other than by a mandrel shall be used. Where the mandrel is used, the mandrel shall be furnished by the Contractor and pulled by hand though the pipeline with a suitable rope or cable connected to each end. Winching or other means of forcing the deflection gauge through the pipeline will not be allowed. The mandrel shall be of a shape similar to that of a true circle enabling the gauge to pass through a satisfactory pipeline with little or no resistance. The mandrel shall be of a design to prevent it from tipping from side to side and to prevent debris build-up from occurring between the channels of the adjacent fins or legs during operation. Each end of the core of the mandrel shall have fasteners to which the pulling cables can be attached. The mandrel shall have nine various sized fins or legs of appropriate dimension for various diameter of pipes. Each fin or leg shall have a permanent marking that states its designated pipe size and percent of deflection allowable. The outside diameter of the mandrel shall be 95 percent of the base inside diameter, where the base inside diameter is:
1.For all PVC pipe: as defined using ASTM D 3034 methodology.
2.For all PE and CPP pipe: the average inside diameter based on the minimum and maximum tolerances specified in the corresponding ASTM or AASHTO material specifications. If the pipe is found to have a deflection greater than that specified, that pipe section shall be removed, replaced, and retested.
542.05 Method II Construction. Method II Construction may be used to
construct pipe culverts, except entrance culverts, only when specified or when physical conditions are encountered in construction which make the use of Method I Construction impractical and written permission is obtained from the Engineer. In Method II Construction, all or a portion of a pipe culvert may be constructed in a trench excavated in the existing ground prior to placement of the required embankment. The construction procedures for Method II Construction shall be the same as previously specified in Article 542.04 for Method I Construction, except as follows.
a.Trenching. Trenching shall be according to Article 542.04(b), except the trench depth shall be such that the bottom of the pipe is at least one-tenth of its diameter (or equivalent diameter) below the top of the trench. When the Art. 542.05 Pipe Culverts bottom of the pipe is less than the specified distance below the natural ground line, sufficient embankment shall be constructed to an elevation that will provide the required pipe embedment.
b.Backfill and/or Embankment. Backfill and/or embankment extending to an elevation of 1 ft (300 mm) over the top of the pipe shall be constructed according to Articles 542.04 (f) and 542.04(g), except that the material up to the elevation of the center of the pipe and extending to a width of at least 18 in. (450 mm) on each side of the pipe, exclusive of the outer 3 ft (1 m) at each end of the pipe, shall consist of aggregate. At the outer 3 ft (1 m) at each end of the culvert, impervious material shall be used.
542.06 Method III Construction. Entrance culverts shall be constructed
according to the following.
a.Trenching. Normally, trenching other than that necessary to place the pipe culvert to a depth equal to one-tenth of its external diameter will not be required. Additional trenching may be necessary in some cases due to the location of a pipe culvert. The trenching shall be performed as specified for Method II, except as follows. The trench shall be excavated only to the bottom of the pipe culvert and for a width sufficient to place the pipe. The bottom of the trench shall be shaped to approximately the size and shape of the pipe culvert.
b.Preparation of Foundation. After the trench has been excavated for the entire length of the pipe culvert and any necessary removal and replacement of unstable or unsuitable material or rock has been completed, the bottom of the trench shall be shaped to substantially fit the exterior of the pipe. If necessary, material meeting the approval of the Engineer shall be used to fill depressions. The material comprising the foundation shall then be compacted to the satisfaction of the Engineer.
c.Laying Pipe. The pipe shall be laid as specified in Article 542.04(d).
d.Backfill and/or Embankment. As soon as the condition of the pipe culvert will permit, the trench shall be backfilled and/or embankment constructed. The material used shall be select material, meeting the approval of the Engineer, from excavation or borrow. The material shall be placed in lifts not exceeding 8 in. (200 mm), loose measurement, and compacted by mechanical means to the satisfaction of the Engineer. Special care shall be taken to completely fill the space under the pipe. The material shall be placed to an elevation 1 ft (300 mm) above the top of the pipe culvert or to the finished grade, whichever is the lesser height. When embankment is being constructed, the material used for its construction shall be placed to a width, on each side of the pipe culvert, not less than one diameter of the pipe. Pipe Culverts Art. 542.07
e.Deflection Testing. Deflection testing for entrance culverts may be required at the option of the Engineer. When required, it shall be according to
Cast grating and frames shall not be galvanized. Either steel frames and grating or cast frames and grating may be used at the Contractor's option, but steel frames with cast grating or cast frames with steel grating will not be permitted. Pressure lock type steel grating and riveted steel grating with reticuline bars will be accepted for galvanizing according to the requirements of AASHTO M 111. Steel grating shall seat firmly in the frame but shall not be secured to the frame. The grating shall be cut in such manner that all riveted or welded connections are left intact. The edges of the main bearing bars Pipe Culverts Art. 542.11 shall be laterally supported by transverse bars. Grating shall be approved by the Engineer. All welding shall be done according to the applicable requirements of Section 505, and shall be done before galvanizing.
a.Standards 542526 and 542531. The steel grating shall have the main bearing bars running perpendicular to the centerline of the inlet box. The main bearing bars shall have a minimum section modulus of 3.29 cu in./ft (176,900 cu mm/m) width of grating. The cross sectional shape shall be rectangular or a modified "I" but shall not have any flanges which would retain trash. The length and width of the grating shall be such as to leave no more than 5/8 in. (16 mm) clearance on either side when placed in the frame.
b.Standard 542546. The steel grating shall have the main bearing bars running parallel to the centerline of the median. The main bearing bars shall be as specified or shall be 3 1/2 in. (89 mm) in depth and have a minimum section modulus of 3.78 cu in./ft (203,200 cu mm/m) width of grating with a maximum spacing of 2 in. (50 mm) center-to-center.
542.08 Pipe Elbows, Tees, and Collars. Pipe elbows and tees shall be
installed at the locations shown on the plans. The degree of elbow and the pipe size required for elbows and tees will be detailed on the plans and shall be verified in the field. Elbows, tees, and collars shall be of the same material as the pipe culvert.
a.Reinforced Concrete. Reinforced concrete elbows and tees shall be fabricated according Article 1042.06. Reinforced concrete collars shall be constructed according to Section 503 and as detailed on the plans. b.Metal. The bonding or connecting device for the elbows, tees, and/or collars will be approved by the Engineer prior to use.
542.09 Pipe Culverts (Temporary). Pipe culverts used as drainage
structures for proposed temporary connections and detour roads shall be designated Pipe Culverts (Temporary) and shall be furnished, installed, maintained, and removed as specified, except the pipe culvert need not be new. When a used culvert is furnished, the Engineer will visually inspect the pipe for acceptance.
542.10 Pipe Culverts (Jacked). Pipe culverts jacked in place shall be
according to Articles 552.02 through 552.06.
542.11 Method of Measurement. Pipe culverts will be measured for payment
in place in feet (meters), except the length measured will not exceed the length shown on the plans or authorized in writing by the Engineer. When elbows or tees Art. 542.11 Pipe Culverts are included in pipe culverts, the measured length of the culvert shall exclude the length of the elbow or tee section. Pipe culverts jacked in place will be measured for payment in place in feet (meters) of the pipe installed by jacking. Excavation in rock will be measured for payment according to Article 502.12. Trench backfill will be measured for payment according to Article 208.03. Embankment will be measured for payment according to Article 202.07 and/or
Additional embankment and its subsequent removal will not be measured for payment.
542.12 Basis of Payment. This work will be paid for at the contract unit price
per foot (meter) for PIPE CULVERTS, or PIPE CULVERTS (TEMPORARY), of the class, type, and diameter or equivalent size specified; PIPE CULVERTS, SPECIAL, of the size specified; or PIPE CULVERTS (JACKED), of the diameter or equivalent round size specified. The removal of unstable or unsuitable material, or rock below plan bedding grade, and the replacement with the specified material, including additional excavation required to widen the trench will be paid for according to Article 109.04 unless the contract contains unit prices for the work included. Excavation in rock will be paid for according to Article 502.13. Embankment will be paid for according to Article 202.08 and/or Article 204.08. Trench backfill will be paid for according to Article 208.04 When the Contractor has the option of using either cast-in-place reinforced concrete end sections or prefabricated end sections as specified in Article 542.07, the work will be paid for at the contract unit price per each for END SECTIONS, for the size of pipe specified. When specified on the plans, precast reinforced concrete flared end sections will be paid for at the contract unit price per each for PRECAST REINFORCED CONCRETE FLARED END SECTIONS, of the diameter or equivalent round size specified. When specified on the plans, steel end sections and aluminum end sections will be paid for at the contract unit price per each for STEEL FLARED END SECTIONS and ALUMINUM FLARED END SECTIONS, respectively, of the diameter or equivalent round size specified. End sections for polyvinylchloride (PVC) and polyethylene (PE) culvert pipes will be paid for at the contract unit price per each for METAL FLARED END SECTIONS, of the diameter or equivalent round size specified. Insertion Lining of Culverts Art. 543.02 When cast-in-place reinforced concrete end sections are specified on the plans, the work will be paid for at the contract unit price per each for CAST-IN-PLACE REINFORCED CONCRETE END SECTIONS, of the diameter specified. When cast-in-place concrete collars are specified on the plans, the concrete will be paid for at the contract unit price per cubic yard (cubic meter) for CONCRETE COLLAR. Reinforcement will be paid for according to Section 508. Expansion bolts, when required, will be paid for according to Section 540. When specified on the plans, elbows and tees for polyethylene or metal pipe will be paid for at the contract unit price per each of PIPE ELBOW and PIPE TEE, of the diameter specified. Inlet boxes for median slopes and for side slopes will be paid for at the contract unit price per each for INLET BOX, STANDARD 542501; INLET BOX, STANDARD 542521; INLET BOX, STANDARD 542511; INLET BOX, STANDARD 542506; INLET BOX, STANDARD 542536; INLET BOX, STANDARD 542516; and INLET BOX, STANDARD 542541. Inlet boxes for median ditch checks will be paid for at the contract unit price per each for INLET BOX, STANDARD 542526 or INLET BOX, STANDARD 542531. Inlet boxes to be placed flush in medians will be paid for at the contract unit price per each for FLUSH INLET BOX FOR MEDIAN, STANDARD 542546. Reinforced concrete pipe elbows will be paid for at the contract unit price per each for REINFORCED CONCRETE PIPE ELBOW, of the diameter specified. Reinforced concrete pipe tees will be paid for at the contract unit price per each for REINFORCED CONCRETE PIPE TEE, of the pipe diameter and riser diameter specified. SECTION 543. INSERTION LINING OF CULVERTS
543.01 Description. This work shall consist of insertion lining of existing pipe
culverts and placing grout or cellular concrete in the annular space between the existing culvert and the liner.
543.02 Materials. Materials shall be according to the following.
Item Article/Section
a.Polyethylene (PE) Solid Wall Pipe with a Smooth Interior (Note 1) ... 1040.04
b.Polyethylene (PE) Profile Wall Pipe (Note 1) ...................................... 1040.04
c.Reinforced Plastic Mortar (RPM) Pipe (Note 1) .................................. 1040.05
d.Corrugated PVC with a Smooth Interior (Note 1) ............................... 1040.03
e.Corrugated Steel Pipe (Note 1)(Note 3) .............................................. 1006.01
f.Steel Casing (Note 1)(Note 4) ........................................................ 1006.05(d)
g.Grout Mixture (Note 2) ........................................................................ 1024.01
h.Portland Cement Concrete ...................................................................... 1020
i.Controlled Low-Strength Material ............................................................ 1019
j.Cellular Concrete .................................................................................... 1029
Source: Illinois Standard Specifications for Road and Bridge Construction, 2022 Edition. Pages 468–496 of 1,217.