1710.4PREQUALIFICATION

KS · 2015 Standard SpecificationsBook pages 808809View official source ↗

1710 – GEOSYNTHETICS

1700-18 Table 1710-1: Base Course Reinforcement Ge Osynthetic Mimimum Averge Roll Values

Property Test Method Requirements Tensile Strength (at 5% strain) ASTM D 4595 580 lb/ft MD 900 lb/ft CD Tensile Strength (at 2% strain) ASTM D 4595 280 lb/ft MD 450 lb/ft CD Coefficient of Soil Interaction GRI-GT6/GG5 0.8 Junction Strength (geogrid) GRI:GG2 25 lbs Permittivity (geotextile) ASTM D 4491 0.40 sec-1 Apparent Opening Size* (geotextile) ASTM D 4751 30 U.S. Sieve (0.0232 inches) Aperture Stability (geogrid) ** Minimum of 0.32 m-N/Deg (MD direction) * ASTM D 4751: AOS IS A MAXIMUM OPENING DIAMETER VALUE ** The Aperture Stability is based on resist ance to in-plane rotational movement m easured by applying a 20 kg-cm (2 m-N) moment to the central junction of a 9 inch by 9 inch specimen restrained at its perimeter in accordance with U.S. Army Corps of Engineers Methodology for measurement of Torsional Rigidity. The coefficient of interaction is ba sed on the soil being a granular, non-cohesive material with less than 10% fines. If these base soils are not available, perform a site specific design and increase the base course thickness, accordingly.

g.Subgrade Stabilization. Provide a woven geotextile, geogrid or geogrid/geotextile combination, as specified in the Contract Document s, for subgrade stabilization that complies with the properties in TABLE 1710-2 . This table is only applicable for subgrades with CBR values greater than 1. For subgrades with CBR values less than 1, a site specific design will be required. TABLE 1710-2: SUBGRADE STABILIZATION GEOSYNTHETIC MIMIMUM AVERGE ROLL VALUES Property Test Method Requirements Tensile Strength (at 5% strain) ASTM D4595 810 lb/ft MD 1340 lb/ft CD Tensile Strength (at 2% strain) ASTM D4595 410 lb/ft MD 620 lb/ft CD Coefficient of Soil Interaction GRI-GT6/GG5 0.8 Junction Strength (geogrid) GRI:GG2 25 lbs Permittivity (geotextile) ASTM D4491 0.40 sec-1 Apparent Opening Sizea (geotextile) ASTM D4751 30 U.S. Sieve (0.0232 inches) aASTM D 4751: AOS is a Maximum Opening Diameter Value
h.Pavement Waterproofing Membrane. Provide an asphalt saturated paving fabric coated with a rubberized asphalt adhesive that complies with the properties in TABLE 1710-3 . TABLE 1710-3: PAVEMENT WATERPROOFING ME MBRANE MIMIMUM AVE RGE ROLL VALUES Property Test Method Requirements Permeance-Perms ASTM E 96 Method B 0.10 perms (max) Pliability (180° bend on a 1/4” mandrel @ -25°F) ASTM D 146 No cracking in fabric or rubber Puncture Resistance ASTM E 154 200 lbs Tensile Strength ASTM D 882 50 lbs/in If required, provide a material for a prime coat (comprised of refined asphalt and a rapidly drying solvent) that complies with the requirements of DIVISION 1200. 1710.3 TEST METHODS Test geosynthetic materials according to the ASTM test methods cited in subsection 1710.2 . 1710.4 PREQUALIFICATION
a.All material provided under this specification must be prequalified through the Engineer of Tests. 1710 – GEOSYNTHETICS

1700-19 b. Manufacturers interested in prequalif ying material under this specification must provide, to the Engineer of

Tests, at least a 1 foot by 1 foot sample of the material, installation instructions for the material, certification that the properties of the type of material submitted meet the re quirements of this specification, current NTPEP testing results associated with the type of material submitted and any other information requested by the Engineer of Tests.

c.The submittals will be evaluated for compliance with th is specification, and the manufacturer will be notified of the results.
d.Approved materials will be placed on the prequalified list maintained by the Bureau of Construction and Materials. Products will remain on the prequalified list as long as the field performance and NTPEP test results of the product are satisfactory. 1710.5 BASIS OF ACCEPTANCE
a.Prequalification as specified in subsection 1710.4 .
b.Receipt and approval of a Type C certification as specified in DIVISION 2600 for each shipment. A shipment consists of all material arriving at the job site at substantially the same time but in no instance greater than 1 week. Each week will constitute a new time period requiring a new Type C certification even if the site has been supplied continuously from the previous week.
c.Visual inspection of the material at the job site for quality of workmanship and damage incurred during shipping or job site storage.
Source: Kansas Standard Specifications for State Road and Bridge Construction, 2015 Edition. Pages 808809 of 978.