815 - CATCH BASINS, INLETS, OU TLETS, MANHOLES, JUNCTION BOXES & OTHER EXISTING STRUCTURES
800-49 h. Painting. Paint structural steel cover pl ates with 1 shop coat of an a pproved primer, 1 field coat of
aluminum paint (tinted) and 1 field coat of aluminum paint. Perform painting as specified in SECTION 714 . Painting of castings is not required unl ess shown in the Contract Documents.
815-1 for increases and decreases in the height indicated in the Contract Documents.
TABLE 815-1: CHANGE IN HE IGHT PAYMENT ADJUSTMENTS Change in Height (feet) Increment of Increases or Decreases in Unit Bid Price Total Increase or Decrease 0 to 0.49 None None 0.50 to 1.00 7.5% 7.5% 1.01 to 2.00 10.0% 17.5% 2.01 to 3.00 12.5% 30.0% For change in height of more than 3.00 feet, the in crement of increase or decreas e is 15% for each foot or fraction over 3.00 feet. OSHA requires different construction procedures and safety requirements when excavated depths reach 5.0 feet or greater. In consideration of this , if a plan height of less than 5.0 feet is adjusted to a height of 5.0 feet or greater, or a plan height of 5.0 feet or greater is adjusted to a height of less than 5.0 feet, an additional 25% of the unit price will be added or deducted from the bid price. This is in addition to normal correction applied from the TABLE 815-1 .