800-42Repair damaged retroreflective sheeting on the sign f aces. Use pressure sensitive retroreflective sheeting to

KS · 2015 Standard SpecificationsBook pages 533537View official source ↗

812 - PERMANENT SIGNING

800-42 Repair damaged retroreflective sheeting on the sign f aces. Use pressure sensitive retroreflective sheeting to

patch the damaged areas, overlapping the damages area a mi nimum of ¼ inch. Match the retroreflective sheeting patch to the adjacent pieces of sheeting for color and uni form appearance and brillian ce under both day and night illumination. Repair damaged galvanized areas on posts and structural members by cleaning and painting with zinc-rich paint.

f.Delineators and Object Markers. Install delineators and object ma rkers as shown in the Contract Documents.
g.Remove and Reset Existing Signs. Remove, transport, store and re set existing signs according to the details in the Contract Documents. Provide new bolts, nuts , washers, post clips and other attachments as necessary to reset the existing signs. When directed by the Engi neer, repair or replace all existing signs damaged during the removal and resetting operations at own expense. 812.4 MEASUREMENT AND PAYMENT The Engineer will measure the finished face of flat sheet signs, reinforced panel signs and sign overlays by the square foot. The Engineer will measure wood posts, steel beam posts , "U" steel posts, perforated square steel tube posts, structural steel posts, aluminum posts and concrete footings by the linear foot. If the alternate grade of steel beam posts is provided, the measurement is based on the primary grade steel size and weight posts. The Engineer will measure various sizes and types of each sign stub post with breakaway base plate, sign post breakaway base plate, perforated square steel tube sign post footing, object marker and delineator. The Engineer will measure removal and resetting of existing sign by the lump sum. The Engineer will measure each barricade, sign po st square coupler and sign post coupler footing. Payment for the various permanent signing bid items at the contract unit prices is full compensation for the specified work. 813 - RUMBLE STRIPS (MILLED) AND RUM BLE STRIPS (MILLED) (CENTERLINE)

800-43 Section 813

RUMBLE STRIPS (MILLED) 813.1 DESCRIPTION Construct milled rumble strips in the existing surface by milling concav e depressions into the surfaces as shown in the Contract Documents. BID ITEMS UNITS Rumble Strips (Milled) (*) Station Rumble Strips (Milled) (*) (Centerline) Station Rumble Strips (Milled) (*) (Edgeline) Station *Asphalt or Concrete 813.2 MATERIALS - None specified. 813.3 CONSTRUCTION REQUIREMENTS

a.General . Use equipment capable of milling the concave depressions with a smooth cut to the dimensions shown in the Contract Documents. Use equipment with the milling head suspended independently from the machine, and that will self-align (parallel to the shoulder surface) with the surface of the paved shoulder regardless of the shoulder slope. Mill the concave depr ession to obtain a relativ ely smooth surface, with a maximum tolerance of ⅛ inch between peaks and valleys. Before beginning work on the project, demonstrate to the Engineer, the ability to ach ieve the specified rumble strip depressions with regard to dimensions, alignment, smoothness and consistency. Construct a test strip approximately 75 feet longitudinally, at a site mutually agreed upon between the Engineer and Contractor, to demonstrate compliance with the requirements. Provide adequate guide marks (approximately 2 inches by 12 inches at approximately 30 to 50-foot intervals) for milling the rumble strips.
b.Rumble Strips (Milled) . Clean the shoulders before constructi ng the rumble strips. Mill the concave depression to the dimension shown in the Contract Documents. Align the concave depressions as shown in the Contract Documents.
c.Rumble Strips (Milled) (Centerline) . Clean the centerlines before cons tructing the rumble strips. Mill the concave depression to the dimension shown in the Contract Documents. Align the concave depressions as shown in the Contract Documents.
d.Rumble Strips (Milled) (Edgeline) . Clean the edgelines before constr ucting the rumble strips. Mill the concave depression to the dimension shown in the Contract Documents. Align the concave depressions as shown in the Contract Documents.
e.Clean Up . After the concave depressions are milled into the surface, use a power broom or sweeper/vacuum to collect the waste material resulting from the milling operations. Unless specified otherwise in the Contract Documents, uniformly spread the waste ma terial just off the edge of the paved surface. 813.4 MEASUREMENT AND PAYMENT The Engineer will measure rumble strips by the station for each shoulder longitudinall y along the edge of the pavement. The Engineer will measure centerline rumble strips by the station longitudinally along the centerline of the pavement. The Engineer will measure rumble strips by the stati on for each edgeline longitudi nally along the edge of the pavement. The Engineer will not measure bridge decks, accelerati on/deceleration lanes and othe r sections where rumble strips are not constructed. Payment for "Rumble Strips (Milled)", "Rumble Strips (Milled) (Centerline)" and "Rumble Strips (Milled) (Edgeline)" at the contract unit price is full compensation for the specified work. 814 - ELECTRIC LIGHTING SYS TEMS AND TRAFFIC SIGNALS

800-44 Section 814

ELECTRIC LIGHTING SYSTEM S AND TRAFFIC SIGNALS 814.1 DESCRIPTION Install electric lighting systems and traffic signal items as shown in the Contract Documents. B I D I T E M S U N I T S Electric Lighting System Lump Sum Electric Conduit (*) (**) Linear Foot Electric Service Box Each T r a f f i c S i g n a l L u m p S u m Traffic Signal Interconnect Lump Sum Emergency Vehicle System Lump Sum Loop Detector Replacement Linear Foot Loop Detector Replacement (Set Price) Linear Foot *Size **Type: Metallic or Non-me tallic, no entry denotes either is allowed. 814.2 MATERIALS

a.General. Provide equipment and material s for electric lightin g system and traffic signal items that comply with DIVISION 1700 . Provide all parts necessary to complete th e electric lighting system or traffic signal or modify existing systems. Before starting any construction activities, submit for the Engi neer’s approval, a schedule of all equipment and materials for the highway lighting syst em or traffic signal. Submit 7 copies of catalog cuts, diagrams and drawings to the Bureau of Transportation Safety and Technology. The Engineer will accept or reject the equipment or materials within 2 weeks. For concrete foundations, use Grade 3.0 concrete that complies with SECTIONS 401, 402 and 1102 , and steel reinforcement that complies with DIVISION 1600 , unless shown otherwise in the Contract Documents.
b.Standard Fabrication. Fabricate the standards as shown in the Contract Documents. Provide straight standards with a maximum variation of 1 inch at the mid-point of 30 to 45-foot standards and ¾ inch at the mid-point of 20 to 30-foot standards. A maximum static deflection (without wind load) of 4 inches is permitted for poles less than 30 feet in height and 4 ½ inches for poles 30 feet or greater in height. Measure static deflections with ma st arms and luminaries in place. The design of the standard, the mast arm and method of attaching the mast arm to the standard must be approved by the Engineer.
c.Loop Detector Replacement. Provide materials that comply with the specifications of the loop detector owner. The information necessary to contact the owner is shown in the Contract Documents. The Engineer will accept the materials ba sed on catalog cuts and visual inspection.
d.Loop Detector Replacement (Set Price). If the Contract Documents do not designate loop detector replacement, the Engineer may approve th e addition of loop detector replacements at the set price. The Contract Documents may designate loop detect or replacements at the set price. Provide materials that comply with th e specifications of the loop detector owner. The information necessary to contact the owner is shown in the Contract Documents. The Engineer will accept the materials ba sed on catalog cuts and visual inspection. 814.3 CONSTRUCTION REQUIREMENTS
a.Codes and Regulations. Perform all electrical work according to:  National Electric Code.  National Electric Safety Code.  Regulations of the National Board of Fire Underwriters. 814 - ELECTRIC LIGHTING SYS TEMS AND TRAFFIC SIGNALS

800-45  Rural Utility Service (RUS)

 Illumination Engineers Society (IES)  Standards of the American Society for Testing and Materials (ASTM)  American Accommodation Policy  Local ordinances.  Details in the Contract Documents. Before starting any work on existing street lighting an d circuits, obtain daily safety circuit clearance from the serving company. Before beginning work, pull cut-out plugs and warning signs posted at cut-out boxes.

b.General.
1.Provide and install all incidental parts not shown in the Contract Documents which are necessary to complete the electrical system or traffic signal or modify existing systems as shown in the Contract Documents. All utility hookups are subsidiary, unless shown otherwise in the Contract Documents.
2.Provide continuous welds that develop the full strength of the member. (3) Perform welds by the submerged arc process.
4.Grind exposed welds flush with the base material.
5.Smoothly finish all exposed edges of plates which make up the base assembly. Round all exposed corners of such plates to ⅛ inch radius.
c.Removals and Excavations. Perform removals of existing structur es and excavations to minimize damage to existing structures and right-of-way. Remove the existing concrete founda tions (including anchor bolts) to the elevation shown in the Contract Documents. Limit the excavation for the conduits, f oundations and other applia nces to that necessary for the installation of the equipment and materials. Do not excavate until immediately before installing the equipment and materials. Place plastic warning tape (12 inches below the surface) directly over conduit. Place excavated material where no damage and obstructi on to vehicles and pedestrian traffic will occur. Do not impede surface drainage. At the end of each day’s work and at all times wh en construction operations ar e suspended, remove all equipment and other obstructions from the portion of the roadway open for use by public traffic.
d.Backfill. Place the backfill material in uniform layers (maximum 6 inches compacted) evenly on all sides of the structure. Compact the backfill using pneumatic tampers, vibratory compactors or other equipment approved by the Engineer. Compact the backfill to comply with the Contract Documents. If backfill requirements are not specified, compact each layer until no further consolidation is observed. Remove surplus excavated material from the project and dispose on sites approved by the Engineer. Reseed the areas disturbed by the excavations. Hand seeding methods may be used.
e.Replacing Damaged Improvements. Replace all sidewalks, curbs, gutters, pavements and other improvements removed or damaged during installations of the lighting systems or traffic signals. Replace or reconstruct the removed or damaged improvements with the sa me type and quality of materials originally used. If part of an existing slab of concrete pavement or square of si dewalk is removed or damaged, replace the entire slab or square.
f.Foundations.
1.Concrete Foundations. Form the foundati ons and place the concrete according to DIVISION 700 . Hold conduit ends and anchor bolts securely in the proper position when the concrete is placed. Cure the concrete foundations with wet burlap or polye thylene for a period of 72 hours. Prevent concrete temperatures from falling below 32ºF. Do not attach poles until the concrete has cured for 14 days. If a foundation can not be constructed as shown in th e Contract Documents because of an obstruction, the Engineer will determine how to construct the foundation. 814 - ELECTRIC LIGHTING SYS TEMS AND TRAFFIC SIGNALS

800-46 (2) Screw-In Foundation Anchors. Pre-drilling holes fo r screw-in foundation anchors is prohibited. As the

foundation anchors are screwed into the ground, make sure th ey are plumb. The pole base of the screw-in foundation anchor shall be level when the installation is complete. Use the connectors to make minor leveling adjustments on poles with breakaway connectors. Use galvanized or cadmium plated shims or washers (m aximum thickness ¼ inch) to make minor leveling adjustments on other types of poles. Only 1 shim or washer is allowed on any 1 anchor bolt, with a maximum of 2 shims or washers on any pole.

3.Removal of Existing Foundations. Remove the desi gnated existing foundations to the depth shown in the Contract Documents. Backfill the resulting holes according to DIVISION 200 . Dispose of the removed foundations and anchor bolts.
g.Conduit.
1.Run all conductors between standard locations, either in duct or conduit. Use conduit of the size and type shown in the Contract Documents. If desired, use larger size conduit at no additional cost to KDOT. Use the large size conduit for the entire length of the run from outlet to outlet. Do not use reducing couplings. When PVC or HDPE is specified, install acco rding to the manufacturer’s instructions. When steel conduit is used, ream the ends of all conduits to remove burrs and rough edges. Make field cuts square and true so the ends will match for the full diamet er. Do not use slip joints or running threads for coupling conduit. Use an approved threaded union conduit, if a standa rd coupling can not be used. Before couplings are made up, paint threads on all conduits with a rust preventative paint. Fit and ti ghten all couplings until the end of the conduits are brought together. Paint any damaged coating on conduit with rust preventative paint. Thread and cap all steel conduit ends wi th standard pipe caps, until wiring is started. When caps are removed, provide threaded ends with approved conduit bushings. Except factory bends, use conduit bends with a radius of gr eater than or equal to 6 times the inside diameter of the conduit. Where factory bends are not used, make conduit bends without crimping or flattening, using the longest radius practicable. Mark the location ends of all conduit for future electric al circuits in structures with a "Y" a minimum of 3 inches high cut in the face of curb, gutter or wall directly above the conduit.
2.Conduit Entrenched. On electric lighting projects where possible, and on surfacing projects as shown in Contract Documents, install the electrical conduit on straight lines and cover with compacted earth. Place conduit as shown in the Contract Documents. (3) Conduit Jacked. Use TABLE 814-1 to determine the conduit depth. Place conduit under existing pavement by approved jacking or dr illing methods. Do not dist urb pavement without written permission of the Engineer. Keep jacking or drilling pits 2 feet clear of the edge of any type of pavement. TABLE 814-1: JACKED CONDUIT DEPTH Location Conditio n Minimum Depth Pavement 36 inches below top of pavement. Trenches on shoulder and in park areas 36 inches below natural ground level. Finished surface in street areas 36 inches below the street surface.* Railroad tracks 42 inches below top of tie. *Conduit may be laid on top of and secured to th e existing pavement in curbed dividing strips.
4.Vertically extend conduit set in standard bases a pproximately 3 inches above the foundation, or slope towards the base opening where transformer bases are used. Locate conduit entering through the bottom of a pull box near the ends to leave the major portion of the box clear . Terminate conduit entering concrete pull boxes 2 inches inside the box wall and 2 inches or greater above the bottom and slope to facilitate pulling of cable. At all outlets, enter the conduit from the direction of the run. For conduit carried through existing culverts or bridge st ructures, pick up the trenched cable for 3 feet in the ground and run up the face of the culvert headwall to the nearest upper corner or top, through the culvert, down the opposite headwall and into the ground for 3 feet. Fasten conduit to concrete su rfaces by means of approved clamps and fasteners. Clean existing underground conduit to be incorporated into a new system with a mandrel, and blow out with compressed air. Conduit runs shown in the Contract Documents may be changed with approval of the Engineer to avoid underground obstructions.
Source: Kansas Standard Specifications for State Road and Bridge Construction, 2015 Edition. Pages 533537 of 978.