B
HomeLibrariesCopilotSearchProjectsBookmarks
FeedbackHelp Desk
Libraries
Building Codes
Code LibraryIBC — BuildingIRC — ResidentialIFC — FireIPC — PlumbingIMC — MechanicalIFGC — Fuel GasIECC — EnergyNEC — ElectricalModel Codes
Specifications
CSI SpecificationsDOT SpecsTransit SpecsUSACE
Standards
TransportationRailroadFire SafetyAccessibilityStructural
Tools & References
DiagramsAssembliesProductsCalculatorsChecklistsPermits
PricingLog in
Electrical (16000-16999)

2000-8(2) Use an approved laborator y to conduct quality control tests. The la boratory will be considered approved if

KS · 2015 Standard SpecificationsBook pages 877885View official source ↗

2004 - FLY ASH FOR USE IN CONCRETE

2000-8 (2) Use an approved laborator y to conduct quality control tests. The la boratory will be considered approved if

it is properly equipped, has the capabilities to perform the tests required by the Contract Documents and is regularly inspected by the CCRL program. Continued approval of the control laboratory and the source will depend on satisfactory comparison of its test results with the results obtained by the Materials and Research Center.

3.The source has not changed materials, material s ources, equipment or processes since prequalification. 2004.5 BASIS OF ACCEPTANCE
a.Prequalification as specified in subsection 2004.4 .
b.A proper certification must accompany each shipment of fly ash. Provide to the Fi eld Engineer 2 copies of the bill of lading which includes the following certification statement and the signature of a responsible company representative. Certification Statement The material herein has been sampled and tested as prescribed by KDOT and complies with the applicable specification requirements for Class ___ fly ash. Date________________ Signed_______________________________ Identify the bills of lading with a project number, and denote the fly ash source, the type and the quantity in the shipment. Retain these copies at the project or ready mix plant for the Fi eld Engineer's records. In the case of more than one project being supplied by a ready mix plant, the plant must provide the Field Engineer with a copy of the bill of lading, or a signed listing of the bills of lading representing the fly ash incorporated in each project. Note: Verification samples will be obtained by KDOT pe rsonnel at the project site. Test results which do not comply with the Contract Documents may be considered sufficient cause to rescind approval to furnish fly ash on a certification basis. 2005 - FLY ASH FOR STABILIZATION, MODIFICATION AND COLD RECYCLE ASPHALT MATERIAL

2000-9 Section 2005

FLY ASH FOR STABILIZATION, MODIFICATION AND COLD RECYCLE ASPHALT MATERIAL 2005.1 DESCRIPTION This specification covers fly ash which is suitable fo r treatment of sub-grade stabilization and modification, and cold recycle asphalt material. Using fly ash to improve strength is the primary benefit for cold recycle asphalt material and sub-grade stabilization. Changing the moisture sensitivity of sub-grade is the primary benefit of modification, however; soil strength improvements are also exp ected. Fly ash is a finely divided residue that results from the combustion of ground or powdered coal. 2005.2 REQUIREMENTS

a.General. Comply with the physical requirements of ASTM D 5239, paragraph 6.4, and the chemical requirements of ASTM C 618, Table 1, for Class C fly ash. Sample and test production a minimum of once per month for quality control.
b.Fly Ash for Stabilization and Cold Recycle. Do not use fly ash as a substitu te for lime. Meet or exceed a compressive strength of 500 psi at 7 days.
c.Fly Ash for Modification. Meet or exceed a compressive strength of 100 psi at 7 days.
d.Storage and Handling. Store and handle fly ash in closed waterpr oof containers before distribution on the roadway or fill. Other methods of storag e and handling are subject to the approval of the Engineer. Partially caked or set fly ash is unacceptable for use. 2005.3 TEST METHODS Sample the fly ash using KT-29. Test the chemical composition of fly ash in accordance with ASTM C 311. Test physical properties of fly ash by ASTM D 5239, paragraph 6.4. 2005.4 PREQUALIFICATION New sources, sources that have not been used on a KDOT project within the last 12 months, and sources which have allowed the required monthly reporting of quality control test results to lapse, must be prequalified. Submit certified analyses of the quality control tests completed during the 90 day period immediately prior to the prequalification request. Certified analyses are defined as representative materials tested by a laboratory regularly inspected and certified by the Cement and Concrete Reference Laboratory (CCRL). Forward the certified analyses and a 2- quart sample to the Engineer of Tests. The sample will be tested in accordance with this specification, and compared to the certified anal ysis of the quality control test. If the material satisfies all requirements, the source wi ll be placed on a prequalified list. Monthly results of the producers quality control testing are required to be forwarded to the Bureau of Construction and Materials to maintain status on the prequalified list. Active sources will remain on the prequalified list so long as verification samples and monthly test results comply with all requirements and indicate acceptable quality control. 2005.5 BASIS OF ACCEPTANCE Prequalification as required by subsection 2005.4 . Receipt and approval of a Type C certification as specified in DIVISION 2600 . 2006 – SILICA FUME

2000-10 Section 2006

SILICA FUME 2006.1 DESCRIPTION This specification covers silica fume, or microsilica, that may be used as a partial replacement for portland cement and blended hydraulic cement in concrete, when a llowed by other parts of the Contract Documents. Silica fume is a by-product resulting from the reduction of high purity quartz with coal in electric arc furnaces in the manufacture of silicon and ferrosilicon alloys. 2006.2 REQUIREMENTS Provide material which complies with ASTM C 1240. 2006.3 TEST METHODS As specified in ASTM C 1240. 2006.4 PREQUALIFICATION

a.Sources of silica fume must be prequalified. Submit certified analyses of the quality control tests completed during the 6-month period immediately before the prequalification request. Certified analyses are defined as the range of test results of the properties specified above on representa tive materials tested by a laboratory which is regularly inspected and certified by the Cement and Concrete Refe rence Laborato ry (CCRL). Include mill certifications for the raw material.
b.Forward the certified analysis to the Bureau Chief of Construction and Mate rials. If the material satisfies all requirements, the source will be placed on a prequalified list.
c.Verification samples will be taken by each District , at the rate of one per year, for each silica fume producer supplying material to that District's projects.
d.Semi-annual results of the produc er’s quality control testing, as defined above, are required to be forwarded to the Bureau of Construction and Materials to maintain status on the prequa lified list. Sources will remain on the prequalified list, so long as verification samples and semi-annual test results complies with all requirements, and indicate acceptable quality control. 2006.5 BASIS OF ACCEPTANCE
a.Prequalification as specified in subsection 2006.4 .
b.Receipt and approval of a Type C certification as specified in DIVISION 2600 . 2007 – SLAG CEMENT FOR US E IN CONCRETE AND MORTARS

2000-11 Section 2007

SLAG CEMENT FOR USE IN CONCRETE AND MORTARS 2007.1 DESCRIPTION This specification covers slag ceme nt for use in concrete and mortars. 2007.2 REQUIREMENTS Provide material that complies with the requirements of ASTM C 989, “Slag Cement for Use in Concrete and Mortars.” 2007.3 TEST METHODS As specified in ASTM C 989. 2007.4 PREQUALIFICATION

a.Manufacturers desiring to provide material under this specification are to submit the following to the Engineer of Tests: (1) A 2-gallon prequalification sample of each product they wish to prequalify.
2.Complete instructions on the use of the material and a Material Safety Data Sheet (MSDS).
3.Copies of quality control test reports for the 6 m onths before to the date of submittal to substantiate a history of satisfactory quality control. Also, provide evidence that the quality control laboratory is regularly inspected by the Cement and Concrete Reference Laboratory (CCRL).
b.If the prequalification samples comply with the requirements of subsection 2007.2 , and the other submittals are satisfactory, the name of the product will be placed on a list of prequalified products maintained by the Bureau of Construction and Materials.
c.A prequalified plant will reta in its prequalified status as long as test results of random samples obtained by KDOT and quality control samp les obtained by the producer indicate that the plant is exercising acceptable quality control.
d.A terminal established by a prequalified plant will be considered prequalified to supply slag cement under this specification. 2007.5 BASIS OF ACCEPTANCE Prequalification as required by subsection 2007.4 . Receipt and approval of a Type C certification as specified in DIVISION 2600. 2008 – BLENDED SUPPLEMENTARY CEMENTITIOUS MATERIALS FOR USE IN CONCRETE

2000-12 Section 2008

BLENDED SUPPLEMENTARY CEMENTITIOUS MATERIALS FOR USE IN CONCRETE 2008.1 DESCRIPTION This specification covers blended supplementary cementit ious materials (SCMs) that may be used as a partial replacement for portland cement in concrete, when a llowed by other parts of the Contract Documents. 2008.2 REQUIREMENTS

a.All individual SCMs to be blended must be prequalified according to DIVISION 2000 .
b.Provide material that complies with the chemical and physical requirements of ASTM C 1697, except the loss on ignition may not exceed 3.0%. Th e supplementary optional physical requi rements apply, except that with the “Effectiveness in Controlling Alkali-Silica Reaction,” the expa nsion of the test mixture as a percentage of the low- alkali cement control at 14 days may not exceed 120%. Conduct this testing with 15% blended supplementary material and a Type I/II cement with an alkali content between 0.52% and 0.60%. Do not vary the amount of pozzolan or slag cement in the finished blended supplementary cementitious material from the target value by more than 2.5% for silica fume and not more than 5% for other supplementary cementitious materials.
c.The quality-monitoring program must comply with the minimum sampling and testing frequencies established in DIVISION 2000 for the individual materials being blended. If the required sampling and testing frequencies of two or more SCMs vary, the sampling and testing plan of the SCM with the higher frequency will govern. This frequency may be altered with the approval of the Bureau Chief of Construction and Materials, provided the monitoring intent of each material is met or exceeded.
d.There are other requirements that must be met fo r the blended supplementary cementitious materials /cement mixture in addition to those cited above for qualific ation of the blended supplementary cementitious materials alone. Additional testing will be requi red for specific applications. Consult the Contract Docume nts before proposing the use of blended supplementary cementitious materials in concrete. 2008.3 TEST METHODS Sample and test blended supplementary cementitious materials according to DIVISION 2000 . Field sample according to Part V, KT-29. 2008.4 PREQUALIFICATION
a.Becoming Prequalified. Each supplemental cementitious material to be blended must be prequalified for use by KDOT on an individual basis prior to approval of the blended SCMs. Refer to DIVISION 2000 for prequalification requirements for each indi vidual type of material. Each blende d SCM must also be prequalified as follows:
1.Submit the following to the Engineer of Tests:
a.A copy of the quality control plan for the source. The plan should include information on where and how sampling is performed, frequency, a nd what standards (ASTM, etc.) are used.
b.A 2-gallon sample of blended product repr esentative of material intended for use on KDOT projects.
c.Certified test results of SCM produced by the material source during the 6 months immediately before the prequalification request. Show the high, low and average values or statistical analysis for each month.
e.Written evidence of the latest Cement and C oncrete Reference Laboratory (CCRL) inspection of the laboratory performing the SCM testing.
2.The Engineer of Tests will test the submitted sample and review the information submitted by the source, for compliance with the Contract Documents. The Bureau Chief of Construction and Materials will notify the source 2008 – BLENDED SUPPLEMENTARY CEMENTITIOUS MATERIALS FOR USE IN CONCRETE

2000-13 of the results in writing. Sources co mplying with all requirements will be placed on a list of prequalified blended

supplemental cementitious materials sources maintained by the Bureau of Construction and Materials.

3.Prequalification of the source of product will be based on material produced when the material producer is using specific materials, equipment and processes. Any cha nge in materials, materials sources, equipment or processes voids the source prequalification, and a new prequalification will be required.
b.Maintaining Prequalified Status. After a source has gained prequalified status, the source will be permitted to furnish the product for use on KDOT pr ojects provided the following conditions are met.
1.Submit quality monitoring test reports monthly for all monitoring samples.
2.Use an approved laborator y to conduct quality control tests. The la boratory will be considered approved if it is properly equipped, has the capabilities to perform the tests required by the Contract Documents and is regularly inspected by the CCRL program. Continued approval of the control laboratory and the source will depend on satisfactory comparison of its test results with the results obtained by the Materials and Research Center.
3.The source has not changed materials, material s ources, equipment or processes since prequalification. 2008.5 BASIS OF ACCEPTANCE
a.Prequalification as specified in subsection 2008.4 .
b.A proper certification must accompany each shipment of blended product. Provide to the Field Engineer 2 copies of the bill of lading which includes the following certification statement and the signature of a responsible company representative. Certification Statement The material herein has been sampled and tested as prescribed by KDOT and complies with the applicable specification requirements for Blended Supplementary Cementitious materials with the following designation: ____________. Date________________ Signed_______________________________ Identify the bills of lading with a project number, and denote the product source, the type and the quantity in the shipment. Retain these copies at the project or ready mix plant for the Fi eld Engineer's records. In the case of more than one project being supplied by a ready mix plant, the plant must provide the Field Engineer with a copy of the bill of lading, or a signed listing of the bills of lading representing the blended product incorporated in each project. Note: Verification samples will be obtained by KDOT pe rsonnel at the project site. Test results which do not comply with the Contract Documents may be considered sufficient cause to rescind approval to furnish blended supplementary cementitious material on a certification basis. 2101 - TOPSOIL

2100-1 Section 2101

TOPSOIL 2101.1 DESCRIPTION This specification covers the material requirements for topsoil. 2101.2 REQUIREMENTS Topsoil is the top six inches of field or pasture loam and has a good supply of humus along with a high degree of fertility. Good topsoil has a loose crumbly structure.  Topsoil handled too wet or soggy are not acceptable.  Soils from ditch bottoms, dr ained ponds or eroded areas are not acceptable.  Soils supporting growth of noxious weeds, as defined by The Kansas Seed Law, or undesirable weeds, are not acceptable. 2101.3 TEST METHODS None Specified. 2101.4 PREQUALIFICATION None Specified. 2101.5 BASIS OF ACCEPTANCE Visual inspection by the Engineer fo r compliance with this specification. 2102 - PLANTS

2100-2 Section 2102

PLANTS 2102.1 DESCRIPTION Material requirements for Plants. 2102.2 REQUIREMENTS

a.General.
1.Referenced Specifications and Standards:
a.DataScape Guide to Commercial Nomenclature, latest edition, American Nurseryman Publishing Co. (b) American Standard for Nursery Stock, latest edition, American National Standards Institute, Inc.: ANSI Z60.1
2.Quality and Size. Provide plants that comply with all applicable portions of ANSI Z60.1. Only plants free of noxious weeds, insect infesta tions, mechanical injury, di seases, or defects are acceptable for use under this specification. Plant growth is to be vigo rous, symmetrical and typical for the species. Provide the minimum acceptable size specified in the Contract Documents, meas ured before pruning and with branches in normal position. Larger plants may be substituted, at no change in the Contract unit price, if approved by the Engineer.
3.Container Plants. Container grown nursery plants may be substituted for balled and burlapped plants if approved by the Engineer. (4) Inspection of Plants. Plants must comply with any permits, certifications or inspections required by State, Federal or other authorities. Inspection by the Engi neer of all plants may be done at any time before final planting. Immediately remove reject ed plants from the project site. Identify the plant’s genus, species, cultivar and common na me with a tag attached to each plant or attached randomly in groups of smaller plants. Plants held in storage will be rejected if they show si gns of shriveled and dry tops or roots, or if the plant has new growth that developed while in storage. Move deciduous plants from the nursery field before leaf buds have opened. Deciduous plants moved after leaf buds have opened will be rejected, unless written approval is provided by the Engineer.
b.Balled and Burlapped Plants (B & B). Balls must be firm, natural and completely wrapped with jute, flax or hemp burlap. Do not wrap using plastic or polyethylene fabric wrapping. Secure the burlap with rope, twine or wire to hold the ball in a firm, rigid condition. Balls that are crushed, deformed or broken will be rejected. Only nursery stock that has been harvested during the current planting season is acceptable. The Engineer may accept plants with root balls smaller than specified if the plants were grown in “root control, in-ground containers.” Remove the fabric bag for root controlled plants and secure the earth ball with burlap before planting.
c.Container Plants. Provide only plants grown in the container for a minimum of 4 months. When the plant is removed from the container for planting, the soil mixture must remain intact with the r oot system reaching the sides of the container. Do not use plants with a heavy, twisted root mass circling the bottom of the container.
d.Bare Root Plants. Provide nursery grown plants with well branched root systems which are characteristic of the species presented. Saturate the root system with an anti-transpiran t gel or treat with acrylates and protect from moisture loss with a suitable covering.
e.Transplanting Established Materials. All established trees, shrubs, and other plants on a project that are to be transplanted are indicated in the Contract Docu ments. The method of moving will be shown, such as B &
B.Use the ball and burlap method when transplanting out of season or when the plants are leafed out. B & B is always used when transp lanting evergreen plants. 2102 - PLANTS

2100-3 During the planting season, small plan ts and trees, 2 inch caliper or less, may be transplanted “bare-root.”

Exceptions to “bare root” planting are shown in the Contract Documents. When transplanting “bare root,” dig the plant with a root spread ⅓ greater than that required for nursery grown plants of the same type, kind and size.

f.Native or Collected Plants. When collected plants are to be supplied, notify the Engineer not less than 5 days before beginning to dig. Dig only inspected and approved plants. The “bare root” requirements of subsection 2102.2 e . will apply.
g.Anti-Desiccant (Anti-Transpirant). Treat all evergreens or plants in partial or total leaf with an anti- desiccant at the nursery before digging or in the case of potted plants, before de livery. A certificati on of treatment by the nursery or the treating agency is to accompany the treated plants. Treat a ll deciduous plants that break dormancy after delivery but before planting. A pply the polyvinyl chloride complex liqui d by dipping or spraying according to the manufacturer’s recommendation. 2102.3 TEST METHODS None Specified. 2102.4 PREQUALIFICATION None Required. 2102.5 BASIS OF ACCEPTANCE
a.Initial Acceptance. Visual inspection and measurement of plan ts by the Engineer and compliance with all applicable provisions of this Section. Additionally, provide the Engineer with th e certificate of treatment for plants treated with an anti-desiccant.
b.Final Acceptance. Compliance with the “plant establishment” provisions of DIVISION 900.
Source: Kansas Standard Specifications for State Road and Bridge Construction, 2015 Edition. Pages 877885 of 978.