1022STEEL BRIDGE HAND RAILING

PA · 2026 Standard SpecificationsBook pages 10711075View official source ↗

1019. 2(c) 1019. 3(b) ChlorideIon Penetration - Independent Laboratory Testing or PennDOT’s MTL Test Standard/Method Accepted Result and Commen t ChlorideIon Penetration AASHTO T 259/260 ≤ 0.80lb/yd3 at 0.5 -1.0-inch depth after 90 days of ponding

• Scaling Resistance. Water/cement ratio between 0.40 to 0.50, minimum 4 ,000 pounds per square inch compressive strength, and 6 -8% air entrained. Revise ASTM C672 /672M to measure the mass loss every 5 cycles .

Table D Scaling Resistance - Independent Laboratory Testing or PennDOT’s MTL Test Standard/Method Accepted Result and Commen t Scaling Resistance ASTM C672 /C672 M -03 Rating 0 at 25 cycles (maximum of 3 at 50 cycles, failure criteria 0.1 lb/ft2 mass loss after 50 cycles)

• Skid Resistance. Penetrating sealers cannot reduce the skid resistance of the concrete wearing surface.

Table E Skid Resistance - Independent Laboratory Testing or PennDOT’s MTL Test Standard/Method Accepted Result and Commen t Skid Resistance ASTM E274 Coefficient of friction ≥90% of the untreated specime n

• Depth of Penetration.

Table F Depth of Penetration - Independent Laboratory Testing or PennDOT’s MTL Test Standard/Method Accepted Result and Commen t Depth of Penetration PDS (product data sheet) ≥ 0.15 inch

• Durability. The penetrating sealer cannot show any signs of weathering, discoloration, or deterioration after 6 months of exposure to atmospheric conditions.

Certify as specified in Section 106.03(b)3.

1019.3CONSTRUCTION —

(a)Boiled Linseed Oil.
1.Areas and Preparation.

1.a General. Thoroughly clean the surfaces of dirt, debris, oil, grease, and foreign matter that would prevent penetrating sealer , adhesion, or drying. Do not use membrane -forming curing compound where linseed oil treatment is to be applied. Apply the penetrating sealer as soon as possible after completion of a structure or portion of a structure.

2.Application. Section 503.3(b)
3.Safety Precautions. Section 503.3(c)
(b)Penetrating Sealers .

1019. 3(b) 1019. 4 hydrocarbons, water blasting equipment with a minimum rated capacity of 5,000 pounds per square inch, a low -pressure sprayer with 0.1 gallons per minute at 25 pounds per square inch or less, and brooms or notched squeegees to spread sealant evenly. The use of a spray bar and several nozzles is the ideal application technique.

2.Surface Preparation. Cure the concrete surface according to the sealer manufacture r’s product

data sheet (PDS) . Clear the surface of all loose particles. Utilize a detergent that has been approved by the sealer manufacturer to remove any visible hydrocarbons from the surface.

Source: Pennsylvania Department of Transportation Specifications, 2026 Edition. Pages 10711075 of 1,522.