B
HomeLibrariesCopilotSearchProjectsBookmarks
FeedbackHelp Desk
Libraries
Building Codes
Code LibraryIBC — BuildingIRC — ResidentialIFC — FireIPC — PlumbingIMC — MechanicalIFGC — Fuel GasIECC — EnergyNEC — ElectricalModel Codes
Specifications
CSI SpecificationsDOT SpecsTransit SpecsUSACE
Standards
TransportationRailroadFire SafetyAccessibilityStructural
Tools & References
DiagramsAssembliesProductsCalculatorsChecklistsPermits
PricingLog in
Structures (1000-1099)

1020TOOTH EXPANSION DAM WITH DRAIN TROUGH

PA · 2026 Standard SpecificationsBook pages 10611065View official source ↗

1015. 4 1015. 4

1015.4MEASUREMENT AND PAYMENT —Linear Foot

Measured from end -to-end of barrier. 1016. 1 1016. 3(b)

1016.1DESCRIPTION —This work is the construction of barrier protective fences , sidewalk protective

fences , and railroad protective fences .

1016.2MATERIAL —Before fabrication, submit shop drawings for review and acceptance.

(a)Protective Fence (Steel).
1.Fabric. Section 1110.01(a), size of mesh, 1 inch.
2.Fabric Tie Wire. No. 9 gage aluminum wire; or No. 9 gage steel wire, galvanized, conforming to

ASTM F626 , or aluminized, conforming to ASTM A491 . Certify as specified in Section 106.03(b)3.

3.Posts, Rails, and Fittings. End, corner, and line posts; top and bottom rails; and brace rails to be

Heavy In dustrial Steel Fence Pipe ASTM F1043 Grade IC 50,000 pounds per square inch minimum yield strength) wi th plain ends. Substitution of High Streng th ASTM F1083 Grade 83000 (83,000 pounds per square inch yield strength) Schedule 40 pipe is allowed at no additional cost to the Department. Fittings and hardware as specified in Section 1110.02(a). Certify as specified in Section 106.03(b)3.

4.Plates. ASTM A709, Grade 36. Certify as specified in Section 106.03(b)3.
5.Welding Material. Section 1105.0 2(t).
(b)Anchor Bolts, Nuts, and Washers. Section 1105.02(c)2, galvanized as specified in Section 1105.02(s).
(c)Caulking Compound. Section 705.7

1016.3CONSTRUCTION —As shown on the Standard Drawings and as follows:

(a)General. Coat the surfaces of the base plates in contact with concrete or masonry, using caulking

compound , before erection . Use caulking compound to seal openings between metal surfaces and concrete after erection and alignment . Fasten fabric to the line posts, top and bottom rails, and brace rails, using tie wires spaced not more than 24 inches apart; fasten to end and corner posts using 3/16 -inch by 3/8 -inch stretcher bar bands. Use stretcher bars with square edges attached by t hreading through the fabric, attached with clamps, or attached by other positive mechanical means. Use brace bands and stretcher bar bands 1/8 inch by 1 inch, with 3/8 -inch diameter by 1 1/2 inches long, non-removable bolts. Do not use bent or damaged posts or rails. Place moisture -proof post tops. Position line -post tops to pass the top rail through the post tops. Place top rails in 20 -foot lengths, with couplings or expansion devices joining the lengths to form a continuous brace for each stretch of fence. Fasten top rails to end and corner posts by means of rail ends and brace bands. Use brace rails at end and corner posts, midway between the top and bottom rail, extending from the end or corner post to the adjacent line posts.

Source: Pennsylvania Department of Transportation Specifications, 2026 Edition. Pages 10611065 of 1,522.