1051DOWNSPOUTING

PA · 2026 Standard SpecificationsBook pages 11511155View official source ↗

1051.1 1051.4 – 1

1051.1DESCRIPTION —This work is the furnishing and installation of downspouting .

1051.2MATERIAL —As shown on the Standard Drawings and as follows:

• Fabricated Structural Steel . Section 1105, galvanized as specified in Section 1105.02(s).

• Fiberglass Pipe and Fittings . ASTM D2996 RTRP with a 30,000 pounds per square inch, minimum short -time rupture strength hoop tensile stress. Use concrete gray as the final color of the reinforced fiberglass pipe, unless otherwise specified. Use a coating that protects the pipe from ultraviolet damage. Use manufacturer recommended paint and fittings.

• PVC Schedule 40 Pipe . ASTM D1785

1051.3CONSTRUCTION —Install downspouting, including the drain box, as indicated, and as shown on

the Standard Drawings .

1051.4MEASUREMENT AND PAYMENT —Linear Foot

1052.1 1052.4 1052 – 1

1052.1DESCRIPTION —This work is construction of an aluminum or steel drain facility to dispose of bridge

deck drainage by free drop through curb barrier.

1052.2MATERIAL —

(a)Aluminum. ASTM B308/B 308M , Alloy 6061 -T6. Certify as specified in Section 106.03(b)3.
(b)Structural Steel. Section 1105.02(a)2
(c)Zinc Chromate Primer . Federal Specification TT -P-645. Certify as specified in Section 106.03(b)3.
(d)Galvanizing. Section 1105.02(s)

1052.3CONSTRUCTION —Construct in accordance with Standard Drawing BC-751M, as indicated, and

as directed.

(a)General. Fabricate the drain from either C8 by 4.25 aluminum channels, or C8 by 11.5 steel channels,

welded together with full penetration welds to form a rectangular section. Alternatively, fabricate a rectangular section, 8 inches by 4 1/2 inches out of 3/16 -inch steel plates.

(b)Aluminum Drain. Coat all surfaces of the drain to be in contact with concrete with two coats of

asphalt paint or zinc chromate primer.

(c)Steel Drain. Galvanize the entire drain after welding according to ASTM A 123.

1052.4MEASUREMENT AND PAYMENT —Incidental to concrete bridge barrier .

Source: Pennsylvania Department of Transportation Specifications, 2026 Edition. Pages 11511155 of 1,522.