637 20. Total harmonic distortion, current and voltage, induced into an ac power line by a signal module shall not exceed 20 percent (20%) , over the operating voltage range specified in Section 14 and wi thin the ambient temperature range specified in Section 4.
660.11 Cabinets :
The cabinets for all types of traffic controllers or flasher units shall be mounted and installed at the location shown on the Plans and in accordance with typical installat ion details. No mounting holes or special outlets shall be made through the cabinet walls without the specific approval of the Engineer. Adjustable steel bands or universal cabinet mounting bands shall not be used for mounting cabinets to poles or pedestals. Cabinets mounted on wood poles shall be attached with wood pole mounting brackets, secured with lag screws.
660.12 Support Structures :
Strain and mast -arm poles shall be installed with the amo unt of rake recommended by the pole manufacturer. The rake shall assure a substantially vertical set when the load is applied. For anchor base type poles, threaded adjusting nuts shall be used to establish the rake. The use of shims or other leveling de vices is not permitted. Hardware and fittings shall be installed as shown on the manufacturer's installation drawings. When embedded or wooden poles are used, the rake shall be established as the pole is set. Pedestal poles supporting only a vertical de ad load shall be installed in a true vertical plane. The Contractor shall take full responsibility for checking all cross sections to determine final support lengths.
660.13 Messenger Cable :
When completely loaded the messenger cable, cable rings and conductor wire shall present a straight, clean, neat appearance. Excessive slack shall be pulled out of conductor wire and the ring supports shall be set at fifteen ( 15) inch centers. Span wire sag shall be kept at a practical minimum and in no case exceed five percent (5%) of the span.