6173 Provide and place reinforcing steel in accordance with Section 514, Reinforcing Steel.

WY · 2021 Standard SpecificationsBook pages 00View official source ↗

Field-cut vertical and horizontal steel to maintain a clearance of at least 2 in [50 mm] vertically and horizontally around the pipe.

617.5MEASUREMENT and PAYMENT

1 The engineer will measure Cut-Off Wall (Conc) and Head Wall (Conc) by the cubic yard

[cubic meter], using the neat lines specified for the computed volume of concrete. Volumes occupied by reinforcing steel and anchor bolts will not be deducted from the concrete volume. The volume occupied by the pipe’s outside diameter will be deducted. 2 When a head wall consists of a cut-off wall portion and slope paving, the entire installation

will be measured as a Head Wall (Conc). 3 The department will pay as follows: 4 Grade fill slopes to match head wall, cut-off wall, or both.

Pay Item

Pay Unit

Measure to the Nearest

Pay to the Nearest

Cut-Off Wall (Conc)

CY [m3]

0.1 ft [0.05 m]

0.1CY [0.1 m3]

Head Wall (Conc)

CY [m3]

0.1 ft [0.05 m]

CY [0.1 m3]

567

Precast Reinforced Concrete Stock Passes

618.1DESCRIPTION

1 This section describes the requirements for constructing precast reinforced concrete

stock passes.

618.2MATERIALS

1 Provide materials in accordance with the following:

Material

Subsection

Admixtures Aggregate for Concrete Bolts and Fasteners Portland Cement Curing Materials Fly Ash Galvanized Coating Reinforced Concrete Stock Passes Reinforcing Steel Water

801.4 803 815.6 801.1 802.1 801.2 815.14 808.2 811.1 814.1

618.3EQUIPMENT—Vacant

618.4CONSTRUCTION

Provide precast reinforced concrete stock pass sections from plants certified in accordance with Subsection 502.4.1, Plant Certification. The department will not accept drycast precast members. Provide sections that vary from specifications no more than:

1.1 percent for internal dimensions;
2.¼ in [6 mm] for haunch dimensions;
3.5 percent less for slab and wall thicknesses; and
4.¾ in [19 mm] for lengths of two opposite surfaces of the box section, except where

bevel ends are specified. 2 Before shipping, shop-assemble at least three sections to verify that joint fit meets the

requirements specified for final assembly.

Excavate for stock passes in accordance with Subsection 206.4.1.1, Culvert

568

Precast Reinforced Concrete Stock Passes

Source: Wyoming Standard Specifications for Road and Bridge Construction, 2021 Edition. Pages 00 of 771.