B
HomeLibrariesCopilotSearchProjectsBookmarks
FeedbackHelp Desk
Libraries
Building Codes
Code LibraryIBC — BuildingIRC — ResidentialIFC — FireIPC — PlumbingIMC — MechanicalIFGC — Fuel GasIECC — EnergyNEC — ElectricalModel Codes
Specifications
CSI SpecificationsDOT SpecsTransit SpecsUSACE
Standards
TransportationRailroadFire SafetyAccessibilityStructural
Tools & References
DiagramsAssembliesProductsCalculatorsChecklistsPermits
PricingLog in
General

615Pay Item

WY · 2021 Standard SpecificationsBook pages 00View official source ↗

Pay Unit

Measure to the Nearest

Pay to the Nearest

Replace Cattle Guard Grill (Medium Duty) ft [m]

EA [Ea]

EA [Ea]

EA [Ea]

Reset Cattle Guard

EA [Ea]

EA [Ea]

EA [Ea]

Reset Cattle Guard (Heavy Duty) ft [m]

EA [Ea]

EA [Ea]

EA [Ea]

Reset Cattle Guard (Medium Duty) ft [m]

EA [Ea]

EA [Ea]

EA [Ea]

615.5.2 Referenced Sections for Direct Payment

When specified, the engineer will measure and pay for cattle guard removal in accordance with Section 202, Removal; however, when reset is specified, removal will be incidental to resetting.

562

Snow Fence

616.1DESCRIPTION

1 This section describes the requirements for constructing and resetting snow fence.

616.2MATERIALS

1 Provide materials in accordance with the following:

Material

Subsection

Bolts and Fasteners Reinforcing Steel Structural Timber and Lumber

815.6 811.1 817.1

2 Provide Lodgepole Pine, Ponderosa Pine, Engelmann Spruce, Douglas Fir, Hem- Fir,

or Western Larch rough-dimension lumber. For 1-inch [25 mm] lumber, provide Western Wood Products Association (WWPA) No. 3 or better, treated or untreated. For 2-inch [50 mm] lumber, provide WWPA No. 2 or better, and when used for line posts and sill-andframe assemblies, provide lumber treated in accordance with American Wood Protection Association (AWPA) Standard U1 to the requirements of Use Category 4A (UC4A) and certificates and reports thereof are submitted, in accordance with Section 817, Structural Timber and Lumber. Use treated timber that is dried to a moisture content of 19 percent after treatment. 3 Provide anchor angles of structural carbon steel in accordance with ASTM A 36 [ASTM

A 36M] requirements. Provide bolts with washers and nylon-insert locknuts. Use plated nails in accordance with ASTM B 633, SC3 or ASTM A 641 [ASTM A 641M], class I coating. Use grade 60 [400] reinforcing steel in the anchorage system. 4 Provide galvanized bolts and fasteners.

616.3EQUIPMENT—Vacant

616.4CONSTRUCTION

616.4.1 New Snow Fence

The department specifies the minimum number of washers. As required, provide additional washers, and adjust bolt lengths to provide a minimum of 1 thread and a maximum of ½ in [13 mm] of thread exposed beyond the outside end of the nut when components are assembled clamp-tight. Do not crush wood fibers by over-tightening.

563

Snow Fence

Source: Wyoming Standard Specifications for Road and Bridge Construction, 2021 Edition. Pages 00 of 771.