B
HomeLibrariesCode AISearchProjectsBookmarksAddress
FeedbackHelp Desk
Libraries
Estimate & calculate
CalculatorsChecklists
PricingLog in
Electrical Systems Materials

3814Emergency Vehicle Pre-Emption Equipment

MN · 2025 Standard Specifications✓ Full text on BuildSpecBook pages 1009–0 Save this section

Ask about Section 3814

Get a cited answer from the section text. Click the citation to check it.

One cited answer a day is free. Start a 14-day trial for unlimited, no card required.

3814.1SCOPE

Provide Emergency Vehicle Preemption/Priority (EVP) Equipment for traffic control signal systems.

3814.2REQUIREMENTS

Use EVP systems and confirmatory indicator lights mounted on traffic control signal mast arms and traffic control signal pedestals. Use mounting hardware and attach to mast arms and pedestals as specified in the Contract and as approved by the Engineer. A EVP Detectors Use EVP systems listed on the APL, Signals. Deliver EVP phase selectors to the Department’s Electrical Services Section at least 30 Business Days before the traffic control signal cabinet is required on the Project. The Department’s Electrical Services Section will review the provided Equipment to ensure the proposed product is listed on the APL, and install the EVP phase selectors into the Department-provided traffic control signal cabinet. B EVP Light Emitting Diode (LED) Confirmatory Indications Only use LED EVP confirmatory indications listed on the APL, Signals. C EVP Round Outlet Box Use an EVP round outlet box for wire splicing with the following:

(1)Nominal 4 inch diameter by 1 1/2 inch deep
(2)Cast aluminum
(3)NRTL listed, for use in wet locations
(4)Threaded openings at the top, bottom, and 2 sides, with threaded caps, to support

3/4 inch conduit

(5)One threaded opening with threaded cap to support a 3/4 inch conduit on the back of

outlet box

(6)Galvanized or zinc-plated screw-on cover for wet locations with weather seal
(7)Threaded nipples with locking washers sized to fit the round outlet box for attached

appurtenances D EVP Condulet Outlet Body Use an EVP condulet outlet body for mounting the EVP detector unit to the EVP round outlet box with the following:

(1)90° up from horizontal
(2)Screw-on cover with weather tight seal
(3)Male threaded end and female threaded end
(4)NRTL listed
(5)For use in wet locations

E EVP Confirmatory Indicator Lamp Holder Use EVP confirmatory indicator lamp holders listed on the APL, Signals.

3814.3SAMPLING AND TESTING

Confirm and document the listing of the EVP systems, EVP LED Confirmation Indications, and the EVP confirmatory indicator lamp holders on the APL, Signals. Obtain the Engineer’s approval of the EVP round outlet box or the EVP condulet outlet body before installation. Provide this documentation to the Engineer.

Get an email when 3814 changes

Minnesota revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Minnesota Standard Specifications for Construction, 2025 Edition. Pages 1009–0 of 1,081. View official source ↗

Ask about this section