3842.1SCOPE
Provide the required electrical systems compounds and lubricants to Materials as specified in the Contract for lubricating and preventing corrosion and oxidation.
3842.2REQUIREMENTS
A Anti-seize and Lubricating Compound “Bridge Grease” Use an approved anti-seize and lubricating compound listed on the APL, Bridge and specified as “Bridge grease.” B Conductor Anti-oxidant Joint Compound Before terminating conductors, coat conductor ends and connectors with anti -oxidant joint compound meeting the following:
Tester, Flash Point: >475°F
Hours: 4,000
by Copper Strip Test, Copper Corrosion Test at 212°F, 24 hours: No Corrosion
Penetration, 60 Strokes at 77°F: 260-310
Point: 572°F
of Lubricating Grease, Water Washout, percent loss at 100°F: <1.00
of Lubricating Greases, Bearing Rust Test: Pass
Lubricating Grease (Four Ball Method), Four Ball EP Load Wear Index: 127.3
Greases, Fretting Wear at 73°F, 22 hours, milligram loss: 7.15 C Ferrous Metal Electrically-Conductive Corrosion Resistant Compound Provide a brush on ferrous metal electrically-conductive corrosion resistant compound on metal threaded conduit fittings to prevent corrosion, oxidation, improve conductivity, and the integrity of electrical connections.
1 percent Zinc
3842.3SAMPLING AND TESTING
The Department reserves the right to sample, test, inspect, and accept or reject electrical systems compounds and lubricants based on its own tests.
Get an email when 3842 changes