3836.1SCOPE

Provide a barrier in pole bases to prevent rodent intrusion in traffic signal mast arm poles and Light Poles.

3836.2REQUIREMENTS

A Stainless Steel Woven Wire Cloth Provide a stainless steel woven wire cloth for rodent intrusion barrier meeting the following:

(1)0.5 by 0.5 per inch mesh
(2)0.041 inch wire diameter
(3)0.159 inch opening width
(4)63.2 percent open area

B Rodent Intrusion Barrier for Light Poles Rodent intrusion barrier listed on the APL, Lighting for specific designed poles. Ensure rodent intrusion barrier can be used with the poles on the Project. C Rodent Intrusion Barrier for Signal Mast Arm Poles Rodent intrusion barrier listed on the APL, Signals for traffic signal mast arm poles with 10 inch and 10 3/4 inch base plate openings may be used.

3836.3SAMPLING AND TESTING — BLANK

Get an email when 3836 changes

Minnesota revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Minnesota Standard Specifications for Construction, 2025 Edition. Pages 1027–0 of 1,081. View official source ↗

Ask about this section

Scoped to Minnesota 2025 Standard Specifications for Construction, Section 3836 — Rodent Intrusion Barrier. Every answer cites the section it came from, with a verification date — don’t trust a percentage, click the citation.