3850.1SCOPE
Provide service cabinets for distributing electrical power, providing over current protection, and providing a means to cut off power to Roadway Lighting Systems.
3850.2REQUIREMENTS
Use Lighting Service Cabinets and sub-assemblies listed and labeled by a National Recognized Testing Laboratory (NRTL) as defined by the U.S. Department of Labor. Ensure the NRTL is listed by OSHA in its scope of recognition for the tests conducted in accordance with this section.
Provide Lighting Service Cabinets meeting the following:
Control Equipment,” and UL 508A, “Standard for Industrial Control Panels”
Use service cabinets listed on the APL, Lighting for Type L1 Service Cabinet, Type L2 Service Cabinet, Type Rural Lighting and Flasher (RLF) Service Cabinet, and Type B Service Cabinet.
3850.3SAMPLING AND TESTING
The Department reserves the right to test, inspect, and accept or reject L ighting Service Cabinets that are not in compliance with requirements as defined in the cabinetS pecifications posted on the APL, Lighting. Planting Materials