3379.1SCOPE

Provide vehicular gates and pedestrian gates with pipe frames.

3379.2REQUIREMENTS

A General Use the same pipe, hardware, fittings, fence wire, and appurtenance Materials to assemble all gates provided to the Project. B Materials Use a frame made of galvanized steel pipe or aluminum alloy pipe.

B.1 Galvanized Steel Pipe Provide galvanized steel pipe meeting the requirements of ASTM A53, Standard Specification for Pipe, Steel, Black and Hot-Dipped, Zinc-Coated, Welded and Seamless, for galvanized Standard Schedule 40 pipe with plain ends. Hydrostatic testing of the pipe is not required. B.2 Aluminum Alloy Pipe Provide aluminum alloy pipe meeting the requirements of AASHTO M 181 Standard Specification for Chain-Link Fence. B.3 Fittings and Hardware As shown on the Plans, use corner fittings, tops, stretcher bars, truss rods, and other required fittings, hardware, and appurtenances made of steel, malleable iron, wrought iron, or aluminum alloy. If using steel or iron, galvanize fittings or hardware in accordance with AASHTO M 181 after fabrication. B.4 Wire Provide barbed wire, gate fabric for woven wire fence, and gate fabric for chain link fence as specified in 3376, “Fence Wire.” C Physical Properties Use gate and members with physical properties as shown on the Plans. Use fittings, hardware, and other required appurtenances capable of being securely fastened and fitted to meet the requirements of the approved design. Provide hinges and catch and locking devices meeting the requirements of an approved design.

3379.3SAMPLING AND TESTING

Submit to the Engineer a manufacturer’s Certificate of Compliance for each component in this section including BABA compliance, if required. Sample and test in accordance with the Schedule of Materials Control .