B
HomeLibrariesCode AISearchProjectsBookmarksAddress
FeedbackHelp Desk
Libraries
Estimate & calculate
CalculatorsChecklists
PricingLog in
Metals and Metal Products

3381Wire Rope and Fittings for Cable Guardrail

MN · 2025 Standard Specifications✓ Full text on BuildSpecBook pages 943–0 Save this section

Ask about Section 3381

Get a cited answer from the section text. Click the citation to check it.

One cited answer a day is free. Start a 14-day trial for unlimited, no card required.

3381.1SCOPE

Provide wire rope and accessory fittings for use in cable guardrail construction.

3381.2REQUIREMENTS

Provide wire rope and fittings for proprietary high-tension cable guardrail systems meeting the manufacturer’s specifications. Provide wire rope and fittings for low-tension cable guardrail meeting the requirements of AASHTO M 30 Standard Specification for Metallic-Coated Steel Wire Rope and Fittings for Highway Guardrail, and the following: A Wire Rope Requirements Provide wire rope meeting the requirements of Type 1 with Class A coating unless otherwise specified.

B Fitting Requirements Unless the manufacturer specifies otherwise, provide bolts and nuts used to assemble the guardrail elements meeting the requirements of ASTM A307, Standard Specification for Carbon Steel Bolts, Studs, and Threaded Rod 60,000 psi Tensile Strength. Provide bolt heads and nuts with dimensions meeting the requirements of ANSI No. B 18.2 for the type shown on the Plans. Use externally threaded fittings including end tie rods, anchor rods, post loops, and splicing studs that transmit direct tensile stress having a tensile strength of at least 75,000 psi. Use internally threaded fittings such as turnbuckles, cable sockets, and nuts capable of withstanding a proof load equal to 85 percent of the proof load requirements for nuts as specified in ASTM A307, Standard Specification for Carbon Steel Bolts, Studs, and Threaded Rod 60,000 psi Tensile Strength, Table III. Use expansion assemblies, cable splices, and connections capable of withstanding a proof load equal to the tensile strength required of the attached wire rope cable or as specified by the manufacturer. Provide steel rectangular plate washers and cable clamps with a tensile strength of at least 60,000 psi. Provide ferrous metal plain circular washers meeting the requirements of ANSI/ASME B 18.22.1, Type A.

3381.3SAMPLING AND TESTING

Provide samples for testing as directed by the Engineer. The Engineer will test wire rope and fittings for cable guardrail meeting the requirements of AASHTO M 30.

Get an email when 3381 changes

Minnesota revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Minnesota Standard Specifications for Construction, 2025 Edition. Pages 943–0 of 1,081. View official source ↗

Ask about this section

Scoped to Minnesota 2025 Standard Specifications for Construction, Section 3381 — Wire Rope and Fittings for Cable Guardrail. Every answer cites the section it came from, with a verification date — don’t trust a percentage, click the citation.