948.1DESCRIPTION—This work is the construction of overhead steel sign structures of the type indicated.

948.2MATERIAL—

(a)Cantilever, Centermount, Monopipe, or Span with Single Plane Truss.
1.Pipe Columns, Struts, and Truss Chords. Provide supplemental CVN testing (Zone 2, non-fracture

critical in accordance with AASHTO Specifications ) for all pipe with nominal wall thicknesses greater than 1/2 inch. The actual yield strength for all pipe, per mill test report, is not to exceed 65,000 pounds per square inch.

1.a ASTM A53/A53M, Grade B, Type E or S; or ASTM A500, Grade B; or ASTM A106, Grade B

1.b API 5L, Grades B, X42 or X52; PSL2 with the following characteristics:

• No jointers allowed

• Do not use thermomechanical rolled or thermomechanical formed (grad e suffix M) pipe on monopipe structures.

• Process of manufacture: seamless, electric resistance welded, or longitudinal seam, submerged arc welded.

2.Truss Webs and Truss Verticals . As specified in Section 948.2(a)1 for tubular members; or

Section 1105.02(a)2 for structural shapes.

3.Steel Angle, Shapes and Plates. Section 1105.02(a)2
4.Press-Break Columns. Section 1105.02(a)2, unless otherwise specifically approved by the Department.

Provide supplemental CVN testing (Zone2, non -fracture critical, in accordance with AASHTO Specifications) for columns with nominal wall plate thicknesses greater than 1/2 inch. Provide a minimum internal surface (concave) bend radius at each press -break that is five times the wall thickness or 1 inch, whichever is larger. (Bends are parallel to direction of mill rolling). The dimension across the flats on fabricated press-break columns may not vary by more than 2% from the specified dimension. The fabricator is responsible for all fabrication adjustments that may be necessary to accommodate any dimensional variation.

(b)Span with Tri-Chord or Box-Shaped Truss. As specified in Sections 948.2(a)1 through 948.2(a)4.
(c)Tapered Tube Structures.
1.Chord and Column Members. Section 1105.02(a)2. Provide supplemental CVN testing (Zone 2,

non-fracture critical, in accordance with AASHTO Specifications) for tube wall thickness greater than 1/2 inch. If press-break columns are used, provide a minimum internal (concave) surface bend radius that is five times the wall thickness or 1 inch, whichever is larger. (Bends re parallel to direction of mill rolling).

2.Steel Angles, Shapes, and Plates. Section 1105.02(a)2
(d)Fabricated Structural Steel. Section 1105, except identify on the shop drawings weld locations, type,

size, process, and nondestructive testing. Shielded Metal Arc Welding (SMAW), Submerged Arc Welding (SAW), Gas Metal Arc Welding (GMAW), and gas-shielded Flux Cored Arc Welding (FCAW) are approved. Galvanize as specified in Section 1105.02(s). If necessary, perform one time weld repair of column to base

plate, column to splice plate, chord to splice plate, and/or circumferential butt welds in chords and columns. If the initial repair fails, seek approval of the Chief Structural Materials Engineer before making any further repairs at the previously repaired location. Column base plates must meet a Class C flatness tolerance, as specified in Section 1111, for structures erected directly on a pre-finished concrete foundation using bridge shoe bedding material. Perform and evaluate all non-destructive testing according to cyclically loaded non- tubular tension criteria.

1.Perform the following minimum ultrasonic testing of Complete Joint Penetration (CJP) groove welds:

1.a On monopipe structures, 100% of the length of all CJP groove welds; on other structures, 25% of the length of the length of each weld connecting columns to base plates, cords to splice plates connection plates to columns and chords, welds on truss seat plates, and longitudinal seam welds on cantilever and center-mount sleeves.

• If a rejectable defect is found on a partially tested weld, then test 100% of the CJP weld length on that plate or sleeve.

1.b 100% of the groove weld length on at least 25% of the number of similar type connections of web members to the truss chords.

• If any rejectable defect is found, double the testing frequency until no rejectable defects are discovered.

2.Perform the following minimum magnetic particle inspection (MT) of fillet welds and Partial Joint

Penetration (PJP) groove welds.

2.a Intermediate member connections: MT 100% of the weldment length on at least 25% of the total number of connections on trusses and towers, respectively.

• If any rejectable defect is found, double the testing frequency until no rejectable defects are discovered.

2.b Welds on truss seat plates, base plates, cantilever and center-mount sleeves, and alternate press-break members and fillet welds connecting backing rings to base plates and flange splice plates: MT a minimum of 25% of the total length of each weld.

• If a rejectable defect is found, then test 100% of the weld on that element.

2.c Welds attaching handhole frames to columns: MT 100% of the length of each weld.

2.d All other connections: MT 100% of the weldments on at least 10% of the total number of connections

• If any rejectable defect is found, double the testing frequency until no rejectable defects are discovered.

3.Perform 100% radiographic inspection of complete penetration longitudinal seam welds on tapered

tube structures and on all press-break columns.

4.The Department’s plant inspector will select weld locations and weldments to be tested when less

than 100% of weld length is required to be tested.

5.Backing rings for full penetration welds must be continuous or butt welded with a full penetration

weld. Perform 100% ultrasonic inspection ( UT) of butt welds in rings 5/16 -inch and thicker. Perform 100% MT on rings less than 5/16-inch thick.

(e)Anchor Bolts, Nuts, and Washers. Section 1105.02(c)3, except anchor bolts must conform to

Grade 55 only.

(f)Class A Cement Concrete. Section 704
(g)Mortar. Section 1001.2(d), with a 1-day compressive strength equal to or greater than 3,750 pounds

per square inch.

(h)Reinforcement Bars. Section 709.1
(i)Stainless Steel U -Bolts and Washers. ASTM A276, Type 304 . Maximum allowable diam eter for

stainless steel U-bolts is 3/4 inch Condition B.

(j)Stainless Steel Nuts. ASTM F594, Alloy Group 1
(k)High Strength Bolts. Section 1105.02(d)

• Furnish bolts, nuts, and washers for testing purposes and test as specified in Section 1050.3(c)7.b.

• U-bolts, other than stainless steel, mustl conform to ASTM A449.

• Stainless Steel U-bolts as specified in Section 948.2(i) may be substituted for ASTM A449 U-bolts for bolt diameters of 3/4 inch and smaller.

(m)Bedding Material for Bridge Shoes. Section 1113.03(h)
(n)Pre-Assembly of Field Connections. Before galvanizing, preassemble field connections of chord

trusses and chord sections to verify geometry and camber. If distortion occurs after galvanizing, re -verify.

(o)Certification. Section 106.03(b)3

948.3CONSTRUCTION—As indicated, as shown on the Standard Drawings, and as follows:

(a)General. Submit detailed shop drawings for review and acceptance. Submit erection drawings as

directed by the Structure Control Engineer conforming to Section 105.02. Material and workmanship not previously inspected will be inspected on the work site. Remove rejected material from the work site. Restore the site to its original condition, including the disposal of excess or unsuitable material.

(b)Foundations. Excavate and construct the foundations of Class A cement concrete, as specified in

the applicable parts of Section 1001.3. Use steel templates provided by the fabricator to accurately set tower base anchor bolts to the correct elevation and alignment. Securely brace the bolts against displacement before concrete is placed. Provide conduit sweeps when required. After constructing the concrete foundations, backfill the excavation around the foundation using acceptable material, in uniform loose layers, not exceeding 4 inches in depth. Compact to the necessary density by means of mechanical tampers.

(c)Bearing Areas. Construct the column base bearing areas of concrete pedestals, in a true and level

position. Provide full bearing under bases. Place bedding material for bridge shoes, if indicated.

(d)Cantilever and Centermount Structures. Adjust cantilever and centermount structures, after the

sign panels and lighting are installed, to make the signs level.

(e)Column Installation and Anchor Bolt Pretensioning. Install sign structure columns, and pretension

the anchor bolts in strict conformance with the following procedure:

1.Remove all dirt or other foreign material from the top of the concrete pedestals or caissons. Clean

top and bottom surfaces of column base plates to the satisfaction of the Representative; remove any burrs or excessive surface galvanizing in the area of th e anchor bolt holes that would prevent proper seating of the washers in the snug tightened condition.

2.Verify that a test nut can be turned onto each anchor bolt to a point below the elevation corresponding

to the bottom of each in-place leveling nut, and can then be backed off the bolt by the effort of one person using a 12-inch long wrench or equivalent without employing a pipe extension on the wrench.

3.Clean and lubricate the exposed threads of all anchor bolts. Clean and lubricate the threads and

bearing surfaces of all nuts. Re -lubricate the anchor bolts and the nuts if more than 24 hours has elapsed since earlier lubrication, or if the bolts or nuts h ave become wet since they were first lubricated.

4.Turn the leveling nuts onto the anchor bolts and align the nuts to their approximate final elevation.

Place one hardened washer on top of each leveling nut.

5.Install column. Column must fit freely over the anchor bolts; do not force column onto anchor bolts.

Support the column with the crane as necessary and adjust leveling nuts to align the column into its proper upright position. Bring all leveling nut washers into contact with the bottom of the base plate.

NOTE: Upon subsequent completion of any column installation and the tightening of all nuts, the clear dimension between the bottom of each leveling nut and the top of the concrete pedestal or caisson must not exceed approximately 1 inch as shown on the Standard Drawings. In no case will this clear dimension ever exceed the diameter of the anchor bolt unless substantiated by design bending calculations for the bolts.

6.Place one hardened washer onto each anchor bolt on top of the base plate, and turn the top nuts

onto the anchor bolts and into contact with the washers on the base plate.

NOTE: If for any reason, the slope of an anchor bolt from vertical, or the slope of the base plate from horizontal, results in a deviation of greater than a 1:40 slope at the bolt/plate intersection, or if a nut cannot be brought into full contact with the base plate after final tightening, a fabricated -to-fit beveled washer must be used in place of a flat washer under each nut at t hat location.

7.Tighten the top nuts to a snug -tight condition using a star tightening pattern. Snug -tight is defined

as the maximum nut rotation resulting from the full effort of one person using a 12-inch-long wrench or equivalent (no pipe extensions). A star tightening pattern is one in which the nuts on opposite or near opposite sides of the bolt circle are successively tightened in a pattern resembling a star.

8.Tighten the leveling nuts to a snug-tight condition using a star tightening pattern as stipulated for top

nuts. At this point, verify that the clear distance between the bottom of each leveling nut and the top of the concrete is compliant with maximum allowable requirements.

9.Before final turn-of-nut tightening of the top nuts, mark the reference position of each top nut in its

snug-tight condition with a suitable marking on one flat, and a corresponding reference mark on the base plate at the same location. Then, using a star tightening pattern and at least two tightening cycles (passes), incrementally turn the top nuts until achieving the total required nut rotation as specified in the table below. After tightening is completed, verify proper rotation at each nut by observing the reference marks, and verify that the nut and washer are in full contact with the top surface of the base plate.

Top Nut Rotation Beyond Snug Tight Anchor Bolt Diam. (in.) F1554 Grade 55 ≤ 1 1/2 1/3 Turn > 1 1/2 1/6 Turn Note: The top nut rotation tolerance is -0, +20 degrees (1/18 turn) from the specified value.

10.Install jam nuts to a snug-tight condition and burr the threads of each anchor bolt immediately above

the jam nut.

11.Install the rodent screen on the base plate.
12.Verify bolt/nut tensioning no sooner than 48 hours, and no later than 7 days after final/complete

installation, as follows:

a.Remove the rodent screen.
b.Using a 12-inch-long wrench, apply a snug-tight force to each top nut (not jam nut) and then to each

leveling nut as stipulated in Paragraphs 7 and 8 above. If any nut rotates by any amount, carefully document the location and approximate degree of rotation of that nut, in writing, and report the information to the Chief Structural Materials Engineer as soon as possible upon completion of the verification.

c.Apply a snug-tight force to each jam nut and replace the rodent screen.
(f)Expansion. Provide a 1 1/4-inch clearance for expansion of structures mounted between concrete

walls. Hand-tighten the nuts on the U-bolts at expansion points on such structures, and then install jam nuts.

(g)Connections Using High-Strength Bolts. Section 1050.3(c)7

948.4MEASUREMENT AND PAYMENT—

(a)Steel Sign Structures. Lump Sum

The price includes removal of existing signs.

(b)Class 3 Excavation. Section 204.4
(c)Class A Cement Concrete. Section 1001.4
(d)Reinforcement Bars. Section 1002.4