Electrical (16000-16999)

603.4081 inch span by 59 inch rise Pipe Arch Option III Line ar Foot

ME · 2020 Standard SpecificationsBook pages 482483View official source ↗

6-12 necessary incidentals for satisfactory completion of the work. Any grout or mortar necessary to repair chipping shall be incidental to the install ation of the pipe ties. Payment will be made under: Pay Item Pay Unit

603.15 12 inch Culvert Pipe Option I L i n e a r F o o t

603.16 15 inch Culvert Pipe Option I L i n e a r F o o t

603.17 18 inch Culvert Pipe Option I L i n e a r F o o t

603.18 21 inch Culvert Pipe Option I L i n e a r F o o t

603.19 24 inch Culvert Pipe Option I L i n e a r F o o t

603.20 30 inch Culvert Pipe Option I L i n e a r F o o t

603.21 36 inch Culvert Pipe Option I L i n e a r F o o t

603.159 12 inch Culvert Pipe Option III L i n e a r F o o t 603.169 15 inch Culvert Pipe Option III L i n e a r F o o t 603.179 18 inch Culvert Pipe Option III L i n e a r F o o t 603.189 21 inch Culvert Pipe Option III L i n e a r F o o t 603.199 24 inch Culvert Pipe Option III L i n e a r F o o t 603.2009 27 inch Culvert Pipe Option III L i n e a r F o o t 603.209 30 inch Culvert Pipe Option III L i n e a r F o o t 603.2019 33 inch Culvert Pipe Option III L i n e a r F o o t 603.219 36 inch Culvert Pipe Option III L i n e a r F o o t 603.229 42 inch Culvert Pipe Option III L i n e a r F o o t 603.239 48 inch Culvert Pipe Option III L i n e a r F o o t 603.249 54 inch Culvert Pipe Option III L i n e a r F o o t 603.259 60 inch Culvert Pipe Option III L i n e a r F o o t 603.269 66 inch Culvert Pipe Option III L i n e a r F o o t 603.279 72 inch Culvert Pipe Option III L i n e a r F o o t 603.289 84 inch Culvert Pipe Option III L i n e a r F o o t

603.30 21 inch span by 15 inch rise Pipe Arch Option III Li near Foot

603.31 24 inch span by 18 inch rise Pipe Arch Option III Li near Foot

603.32 28 inch span by 20 inch rise Pipe Arch Option III Li near Foot

603.33 35 inch span by 24 inch rise Pipe Arch Option III Li near Foot

603.34 42 inch span by 29 inch rise Pipe Arch Option III Line ar Foot

603.35 49 inch span by 33 inch rise Pipe Arch Option III Line ar Foot

603.36 57 inch span by 38 inch rise Pipe Arch Option III Line ar Foot

603.37 64 inch span by 43 inch rise Pipe Arch Option III Line ar Foot

603.38 66 inch span by 51 inch rise Pipe Arch Option III Line ar Foot

603.39 73 inch span by 55 inch rise Pipe Arch Option III Line ar Foot

603.40 81 inch span by 59 inch rise Pipe Arch Option III Line ar Foot

603.41 24 inch Reinforced Conc. Pipe Class IV L i n e a r F o o t

603.42 30 inch Reinforced Conc. Pipe Class IV L i n e a r F o o t

603.43 36 inch Reinforced Conc. Pipe Class IV L i n e a r F o o t

603.44 42 inch Reinforced Conc. Pipe Class IV L i n e a r F o o t

603.45 48 inch Reinforced Conc. Pipe Class IV L i n e a r F o o t

603.46 54 inch Reinforced Conc. Pipe Class IV L i n e a r F o o t

6-13

603.47 60 inch Reinforced Conc. Pipe Class IV L i n e a r F o o t

603.48 66 inch Reinforced Conc. Pipe Class IV L i n e a r F o o t

603.49 72 inch Reinforced Conc. Pipe Class IV L i n e a r F o o t

603.55 Concrete Pipe Ties Group

603.73 Remove and Relay Metal Pipe: L i n e a r F o o t

603.7315 Remove and Relay 15 inch Metal Pipe L i n e a r F o o t 603.7318 Remove and Relay 18 inch Metal Pipe L i n e a r F o o t 603.7324 Remove and Relay 24 inch Metal Pipe L i n e a r F o o t 603.733 Remove and Relay 30 inch Metal Pipe L i n e a r F o o t 603.7336 Remove and Relay 36 inch Metal Pipe L i n e a r F o o t 603.7348 Remove and Relay 48 inch Metal Pipe L i n e a r F o o t 603.7372 Remove and Relay 72 inch Metal Pipe L i n e a r F o o t

603.74 Remove and Relay Concrete Pipe: Linear Fo ot

603.7415 Remove and Relay 15 inch Concrete Pipe L i n e a r F o o t 603.7418 Remove and Relay 18 inch Concrete Pipe L i n e a r F o o t 603.7421 Remove and Relay 21 inch Concrete Pipe L i n e a r F o o t 603.7424 Remove and Relay 24 inch Concrete Pipe L i n e a r F o o t 603.743 Remove and Relay 30 inch Concrete Pipe L i n e a r F o o t 603.7436 Remove and Relay 36 inch Concrete Pipe L i n e a r F o o t 603.7442 Remove and Relay 42 inch Concrete Pipe L i n e a r F o o t 603.7448 Remove and Relay 48 inch Concrete Pipe L i n e a r F o o t 603.7454 Remove and Relay 54 inch Concrete Pipe L i n e a r F o o t 603.746 Remove and Relay 60 inch Concrete Pipe L i n e a r F o o t 603.7472 Remove and Relay 72 inch Concrete Pipe L i n e a r F o o t

603.75 6 inch Inlet Grate Unit Each

603.76 12 inch Inlet Grate Unit Each

603.77 15 inch Inlet Grate Unit Each

603.78 18 inch Inlet Grate Unit Each

603.79 21 inch Inlet Grate Unit Each

603.80 24 inch Inlet Grate Unit Each

603.81 30 inch Inlet Grate Unit Each

603.82 36 inch Inlet Grate Unit Each

SECTION 604 - MANHOLES, INLETS, AND CATCH BASINS

604.01 Description Construct manholes, inlets, and catch basin s.

604.02 Materials Materials shall meet the requirements specifi ed in the following

Sections of Division 700 - Materials: Portland Cement 701.01 Clay or Shale Brick 704.01 C o n c r e t e M a s o n r y B l o c k s 704.03 J o i n t M o r t a r 705.02

Source: Maine Standard Specifications for Road and Bridge Construction, 2020 Edition. Pages 482483 of 817.