618CONCRETE COLLAR FOR PIPE EXTENSION

PA · 2026 Standard SpecificationsBook pages 553557View official source ↗

629.2(d) 629.3(a) System is to be crashworthy according to the 2016 AASHTO MASH. Proprietary end anchor terminals must have a determination by an ISO 17025 accredited testing laboratory stating that the end anchor terminal has either passed a full suite of tests or all critical crash tests per the MASH crash testing matrix and is compliant with the 2016 AASHTO MASH . End anchor terminal is to meet the following requirements:

• Test Level 3 (TL -3)

• Cross Slope = 10(H):1(V) or flatter

(e)Class A and Class AA Cement Concrete. Section 704
(f)Reinforcement Bars. Section 709.1
(g)Curing and Protecting Covers for High -Tension Cable Barrier End Anchor Terminal . Section 711.1
(h)Reflective Sheeting. Section 1103.05
(i)Certification. Section 106.03(b)3

629.3CONSTRUCTION —

(a)Preconstruction Submittals.
1.High -Tension Cable Barrier. Prepare shop drawings as specified in Section 105.02(d).

At a minimum, include the following in the shop drawings to cover all runs of high-tension cable barrier.

• General notes and construction specifications

• Height of each cable in the system from ground line and top of foundation

• Installation tolerances

• Post length and height of each post with respect to the ground level .

• Post spacing along entire length of system .

• Diameter and depth of line post foundations

• Detailed drawings of all posts, hardware, concrete, and reinforcement bars

• Maximum length between turnbuckles, not to exceed 1,100 feet .

• Minimum depth of the line post foundations, as specified in Section 629.3(b)6 .

• Minimum diameter of 12 inches for the line post foundations

Provide Form CS -4171, Certificate of Compliance, for the associated components of the entire high - tension cable barrier system. Include the breaking strength, modulus of elasticity, and amount of force used to elongate the wire rope.

2.High -Tension Cable Barrier End Anchor Terminals. Submit a proposed design to account for

the soil type. Prepare shop drawings as specified in Section 105.02(d). additional cost to the Department. At a minimum, include the following to cover all locations for end anchor terminals:

• Borings and Soil Testing.

ͦ Perform drilling by a prequalified geotechnical drilling contractor listed in Publication 222 . ͦ Prepare and deliver the boring inspection information according to Publication 222, Section 4.11 . ͦ Obtain each boring within 25 feet horizontally of each proposed end anchor terminal location. If two end anchor terminals are close

Source: Pennsylvania Department of Transportation Specifications, 2026 Edition. Pages 553557 of 1,522.