INCIDENTAL CONSTRUCTION

675RANDOM STONE SLOPE WALL

PA · 2026 Standard Specifications✓ Full text on BuildSpecBook pages 594–0 Save this section

Ask about Section 675

Get a cited answer from the section text. Click the citation to check it.

One cited answer a day is free. Start a 14-day trial for unlimited, no card required.

675.1DESCRIPTION—This work is construction of random stone slope walls.

675.2MATERIAL—

• Coarse Aggregate, Type A, No. 1 Stone. Section 703.2

• Class A Cement Concrete. Section 704

• Premolded Expansion Joint Filler. Section 705.1

• Joint Sealing Material. Section 705.4(b) or (c)

• Geotextiles, Class 4, Type A. Section 735

675.3CONSTRUCTION—As shown on the Standard Drawings and as follows:

Construct concrete toe, anchor, and cutoff walls as specified in Section 1001.3. Where the wall butts another rigid concrete structure, place a 1/2 -inch premolded, expansion joint filler. Seal the top 1/2 inch of the joint with joint sealing material. Place rock and geotextiles as specified in Section 850.3. Spot-check the finished surface with a string line. Fill depressions and cut high areas greater than 2 inches as required.

675.4MEASUREMENT AND PAYMENT—Cubic Yard

The Department will measure to include toe, anchor, and cutoff walls.