1017PACKAGED, DRY, COMBINED MATERIALS FOR MORTAR

IL · 2022 Standard Specifications✓ Full text on BuildSpecBook pages 834–835 Save this section

Ask about Section 1017

Get a cited answer from the section text. Click the citation to check it.

One cited answer a day is free. Start a 14-day trial for unlimited, no card required.

Packaged, Dry, Rapid Hardening Mortor Art. 1018.01 SECTION 1013. CHLORIDES

1013.01 Calcium Chloride. Calcium chloride shall be according to

AASHTO M 144 and the following.

a.Portland Cement Concrete Patching. The calcium chloride shall be Type L (Liquid) with a minimum of 32.0 percent by weight (mass) of calcium chloride.
b.Applied. The calcium chloride shall be Type S (Solid) or Type L (Liquid). The Type S may be Grade 1, Grade 2, or Grade 3. Type L shall have a chloride concentration of 30 to 45 percent by weight (mass).

1013.02 Sodium Chloride. Sodium chloride shall be according to

ASTM D 632, Type 1, Grade 1, except that the sodium chloride (NaCl) content shall be a minimum of 96.0 percent. PORTLAND CEMENT CONCRETE ITEMS SECTION 1017. PACKAGED, DRY, COMBINED MATERIALS FOR MORTAR

1017.01 Requirements. The mortar shall be high-strength according to

ASTM C 387 and shall have a minimum 80.0 percent relative dynamic modulus of elasticity when tested according to Illinois Modified AASHTO T 161. The high- strength mortar shall have a water soluble chloride ion content of less than 0.40 lb/cu yd (0.24 kg/cu m). The test shall be performed according to ASTM C 1218, and the high-strength mortar shall have an age of 28 to 42 days at the time of test. The ASTM C 1218 test shall be performed by an independent lab a minimum of once every two years, and the test results shall be provided to the Department. Mixing of the high-strength mortar shall be according to the manufacturer’s specifications. The Department will maintain a qualified product list. SECTION 1018. PACKAGED, DRY, RAPID HARDENING MORTOR OR CONCRETE

1018.01 Requirements. The rapid hardening mortar or concrete shall be

according to ASTM C 928, and independent laboratory test results shall be provided to the Department to show compliance. The mortar or concrete shall have a water soluble chloride ion content of less than 0.40 lb/cu yd (0.24 kg/cu m). The test shall be performed according to ASTM C 1218, and the mortar or concrete shall have an age of 28 to 42 days at the time of test. The ASTM C 1218 test shall be performed by an independent lab a minimum of once every two years, and the test results shall be provided to the Department. Mixing of the mortar or concrete shall be according to the manufacturer’s specifications. The Department will maintain a qualified product list. Art. 1019.01 Controlled Low-Strength Material (CLSM) SECTION 1019. Controlled Low-Strength Material (CLSM)

1019.01 Description. This work shall consist of the materials, proportioning,

mixing, and transporting of controlled low-strength material (CLSM).

1019.02 Materials. Materials shall be according to the following.

Item Article/Section

a.Portland Cement, Type I ......................................................................... 1001
b.Water ...................................................................................................... 1002
c.Fine Aggregate for Controlled Low-Strength Material (CLSM) ........... 1003.06
d.Fly Ash .................................................................................................... 1010
e.Admixtures (Note 1) Note 1. The air-entraining admixture may be in powder or liquid form. Prior to approval, a CLSM air-entraining admixture will be evaluated in the laboratory by the Engineer. The admixture shall be able to meet the air content requirements of Mix 2. The Department will maintain a qualified product list.

1019.03 Equipment. Equipment shall be according to the following.

Item Article/Section

a.Concrete Mixers ................................................................................. 1103.01
b.Batching and Weighing Equipment .................................................... 1103.02
c.Automatic and Semi-Automatic Batching Equipment ......................... 1103.03
d.Mobile Portland Cement Concrete Plants .......................................... 1103.04
e.Water Supply Equipment ................................................................... 1103.11

1019.04 Mix Design Criteria, Mixing, and Proportioning. The mix design

shall meet the following criteria. Mix Design Criteria Parameter Value Flow ≥ 7 in. (178 mm) Air Content 0 – 25 % Dynamic Cone Penetration (DCP) at 3 days ≤ 1.5 in./blow (38 mm/blow) Compressive Strength at 28 and 180 days ≥ 30 psi (207 kPa) to < 150 psi (1034 kPa) The mix shall be produced according to Section 1020. The mixer drum shall be emptied prior to initial batch to ensure that no additional cement fines are incorporated into the mix. The Engineer reserves the right to adjust the proportions of the mix design in the field to meet the design criteria, provide adequate flowability, maintain proper solid suspension, and meet other criteria established by the Engineer.

Referenced in this section

Get an email when 1017 changes

Illinois revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Illinois Standard Specifications for Road and Bridge Construction, 2022 Edition. Pages 834–835 of 1,217. View official source ↗