1063FIBERGLASS FABRIC REPAIR SYSTEM

IL · 2022 Standard Specifications✓ Full text on BuildSpecBook pages 966–967 Save this section

Ask about Section 1063

Get a cited answer from the section text. Click the citation to check it.

One cited answer a day is free. Start a 14-day trial for unlimited, no card required.

Fiberglass Fabric Repair System Art. 1063.01 SECTION 1063. FIBERGLASS FABRIC REPAIR SYSTEM

1063.01 Requirements. The fiberglass fabric repair system shall consist of

two components, fiberglass and bituminous adhesive. The fiberglass fabric shall consist of a heavyweight high strength woven fiberglass roving according to the following physical properties. Strip tensile strength, ASTM D 579 Modified 1 in. (25 mm) cut strip test, Procedure 2 Strain rate of 0.5 in./min (15 mm/min) in a CRE testing machine, 3 in. (75 mm) gauge length, test both warp and fill directions ………………………………800 lb/in. (140 N/mm), min. Weight (Mass) ……………………………………22 oz/sq yd (745 g/sq m), min. The bituminous adhesive shall consist of an asphaltic polymer that has high adhesion and low tack and is compatible with the fiberglass fabric, and shall be according to the following physical properties. Penetration, ASTM D 5 @ 77 °F (25 °C), 100g, 5 sec ............................................................... 30-60 Softening Point, ASTM D 36 ................................. 180 to 240 °F (82 to 116 °C) Viscosity, ASTM D 3236 @ 380 °F (193 °C) Centipoise (Pa·s) ..................................................................... 800-2000 (0.8-2) Thermal Stability, ASTM D 5329 Prolonged Heating Method, 6 hrs @ 400 °F (205 °C) and the retested sample shall be according to the requirements above and the following. Low Temperature Flexibility, ASTM C 711 Mod ......................................................... -10 °F (-23 °C) max. [1 in. (25 mm) diameter mandrel] The fiberglass fabric repair system shall consist of the fabric coated on both sides with bituminous adhesive and shall be according to the following physical properties. Strip tensile strength, ASTM D 579 Modified ....................................... 1000 lb/in. (175 N/mm) min. 1 in. (25 mm) cut strip test, Procedure 2 Strain rate of 0.5 in./min (13 mm/min) in a CRE Testing machine, 3 in. (75 mm) gauge length, test both warp and fill directions. Art. 1065.01 Protective Devices LIGHTING SECTION 1064. RESERVED SECTION 1065. PROTECTIVE DEVICES

1065.01 Fuseholders and Fuses. Fuseholders and fuses shall be as follows.

a.Fuseholders.
1.General. Each fuseholder shall consist of a two-section unit designed to hold small-dimension cylindrical fuses of the type required. Each section shall be permanently marked with line and load side designations and the unit shall have a water and vapor-tight seal when the sections are joined. Two pole quick disconnect fuseholders shall be used unless otherwise specified. The terminals and the contacts in the fuseholder shall be made of tinned copper or other material suitable for contacts as approved by the Engineer. The contacts shall be spring loaded or tulip style to exert contact pressure on mating parts. Fuse holders shall be rated for 30 A at 600 V at 167 °F (75 °C) operation.
2.Fuseholder Material. Fuseholders shall have a molded plastic, neoprene rubber, or impact resistant polymer housing. Wires shall attach to the fuse holder by a crimping operation, except that connection of No. 2 wires to breakaway fuse holder receptacles may be via a set screw connection. Each fuse holder shall be of a size proper for the wires to be attached. The assembly shall be provided with insulating boots as needed.
3.Fuseholder Design. Phase to phase circuit applications shall be designed so that both phase conductors are disconnected at the same time. Phase to neutral circuit applications shall be designed so that both phase and neutral conductors are disconnected at the same time. Blanks shall be used instead of fuses for the neutral conductor and they shall be clearly marked with white bands to designate a neutral plug.
4.Fuseholder Operation. The fuseholder shall be capable of disconnecting upon sufficient tension in the connected wires, as in a pole knockdown. The fuse shall remain enclosed in the de-energized portion of the fuseholder upon disconnection. The fuse shall not be utilized as the disconnection means.
b.Fuses. Fuses for installation within fuse holders for protection of luminaires shall be small-dimension, 1 1/2 in. x 13/32 in. (38 mm x 10 mm), cylindrical fuses of the time-delay type. The fuses shall be rated for 500 V AC and meet the requirements of UL 248-14. The fuses shall have a listed interrupting rating of not less than 10,000 rms symmetrical amperes at rated

Get an email when 1063 changes

Illinois revises spec sections through supplementals and new editions. We check this one every week and email you the day it changes. Free, no account.

Source: Illinois Standard Specifications for Road and Bridge Construction, 2022 Edition. Pages 966–967 of 1,217. View official source ↗

Ask about this section

Scoped to Illinois Standard Specifications for Road and Bridge Construction, Section 1063 — FIBERGLASS FABRIC REPAIR SYSTEM. Every answer cites the section it came from, with a verification date — don’t trust a percentage, click the citation.