1033TEMPORARY RUBBER AND TEMPORARY PLASTIC RAMPS

IL · 2022 Standard Specifications✓ Full text on BuildSpecBook pages 935–935 Save this section

Ask about Section 1033

Get a cited answer from the section text. Click the citation to check it.

One cited answer a day is free. Start a 14-day trial for unlimited, no card required.

Art. 1033.01 Drain Pipe, Tile, and Wall Drain For drainage and utility castings, temporary rubber ramp material shall be according to the following. Property Test Method Requirement Durometer Hardness, Shore A ASTM D 2240 75 15 Tensile Strength, psi (kPa) ASTM D 412 300 (2000) min. Elongation, % ASTM D 412 90 min. Specific Gravity ASTM D 297 1.0 - 1.3 Brittleness, F (C) ASTM D 746 -40 (-40)

1033.02 Temporary Plastic Ramps. Temporary plastic ramps for butt joints

shall be made of high density polyethylene and the Contractor shall furnish a manufacturer’s certification of test results meeting the following requirements. Physical Property Test Method Requirement Melt Index, g/10 min ASTM D 1238 8.2 Density, g/cc ASTM D 1505 0.965 Tensile Strength @ Break, psi (MPa) ASTM D 638 2223 (15) Tensile Strength @ Yield, psi (MPa) ASTM D 638 4110 (28) Elongation @ Yield, % 1/ ASTM D 638 7.3 min. Durometer Hardness, Shore D ASTM D 2240 65 Heat Deflection Temperature, 66 psi, F (C) ASTM D 648 176 (80) Low Temperature Brittleness, F50, F (C) ASTM D 746 < -105 (< -76) 1/ Crosshead speed -2 in./minute MASONRY AND DRAINAGE ITEMS SECTION 1040. DRAIN PIPE, TILE, AND WALL DRAIN

1040.01 Drain Tile. Drain tile shall be according to the requirements of

ASTM C 4. The tile furnished shall be that designated as heavy-duty drain tile. The maximum length of the units shall be 24 in. (600 mm).

1040.02 Clay Pipe. Extra strength clay pipe, extra strength perforated clay

pipe, and clay sewer pipe shall be according to the requirements of ASTM C 700.

1040.03 Polyvinyl Chloride (PVC) Pipe. Acceptance testing of PVC pipe and

fittings shall be accomplished during the same construction season in which they are installed. The section properties shall be according to the manufacturer pre- submitted geometric properties on file with the Department. The manufacturer shall submit written certification that the material meets those properties. The pipe shall meet the following additional requirements.

a.PVC Pipe. The pipe shall be according to AASHTO M 278 or ASTM F 679, except it shall be made of PVC plastic having a minimum cell classification of 12454-C or 12364-C, as defined in ASTM D 1784.