Art. 1076.04 Post and Foundation 1024 The shielding shall be 100 percent effective by providing a metal-to- metal contact between adjacent wraps. The capacitance measured between conductors shall be 30 (100) picofarads or less per foot (meter). The capacitance measured between one conductor and another conductor connected to the shield shall be 55 (180) picofarads or less per foot (meter). (4) Jacket. The jacket shall be polyvinyl chloride according to IMSA No. 39-2, or polyethylene according to IMSA No. 40-6. (5) Identification. Each shipping length of cable shall show the name of the…