PIPE CULVERTS SECTION 601 174 ITEM DESCRIPTION UNIT 601276 CORRUGATED POLYPROPYLENE PIPE , TYPES , 36" LF 601277 CORRUGATED POLYPROPYLENE PIPE , TYPES , 42" LF 601278 CORRUGATED POLYPROPYLENE PIPE, TYPES, 48" LF 601279 CORRUGATED POLYPROPYLENE PIPE , TYPES , 60" LF 601280 PERSONNEL SAFETY GRATE FOR PIPE INLET EACH
DRAINAGE STRUCTURES SECTION 602 175 SECTION 602 — DRAINAGE STRUCTURES
602.1Description.
This work consists of constructing, providing, replacing, adjusting, and repairing drainage inlets, drainage inlet frames and grates, manholes, manhole frames and covers, and junction boxes.
602.2Materials.
602.3Construction.
Standard Construction Details before fabrication for:
proposed structure can handle all loads including the HS -20 live load.
determine the exact sizes of the drainage inlet frames and grates, and manhole frames and covers before placing the order. DRAINAGE STRUCTURES SECTION 602 176 3. For locations that require the repair of existing junction boxes, include field measurements to determine the exact sizes of the top cover slab and hinge. Also include all parts and fittings for installation.
exceeding HS -25 load rating requirements in accordance with AASHTO M306.
requirements of the Standard Construction Details;
and structure requirements.
firm, even surface, to the acceptance of the engineer.
unless otherwise specified in the contract. The contractor may request use of precast structures subject to the engineer’s approval. Use precast structures for new construction unless otherwise specified in the contract.
accordance with AASHTO M199.
deeper when measured from the top of grate or cover to the invert of the lowest pipe , install steps at an accessible location . Ensure that the steps have a minimum embedment of 3 -inches into the wall and protrude out 6 inches from the wall. Begin steps within 24 -inches of the top of grate or lid and place the last step no more than 12 -inches above the lowest invert except where a pipe is in the same wall as t he steps in which case the last step must be placed such that the last step is no more than 12 -inches from the top of the pipe . Place steps vertically 12 - inches apart.
contract and that pipes extend through, and are flush with, the inside of the wall. When cutting off the end of a reinforced concrete pipe, finish with mortar so that no reinforcement steel remains exposed. Fill any space between the pipe and the walls of the drainage inlet with non - shrink grout conforming to the requirements of Section 1047, with a minimum strength of 5,000-PSI. Ensure that the pipe opening in the drainage inlet is no more than 4 -inches larger than the pipe diameter measured from the outside wall of the pipe.
accordance with Section 1022.6 except water curing will not be permitted.