LIGHTING CONTROL CABINETS SECTION 847
532 SECTION 847 — LIGHTING CONTROL CABINETS
847.1Description.
This work consists of providing and installing lighting control cabinets.
847.2Materials.
847.3Construction.
may include mounting to an existing pole or existing cabinet base.
847.3.A.3, above.
box (LB) conduit fitting. After installing the photoelectrical control and LB conduit fitting, seal the area around the hole in the cabinet. Photoelectrical control can also be installed inside of the cabinet behind a plexi -glass shield, if required by the contract and as directed by the engineer.
847.4Method of Measurement.
The Department will measure the quantity of lighting control cabinets as the number provided, installed, and accepted.
847.5Basis of Payment
The Department will pay for lighting control cabinets at the contract unit price per each. Price and payment constitute full compensation for providing and installing all materials. ITEM DESCRIPTION UNIT 847001 INSTALL OR REMOVAL OF POLE OR POST MOUNTED CABINET EACH 847002 INSTALL OR REMOVAL BASE OR PAD MOUNTED CABINET EACH 847003 LIGHTING CONTROL CABINET – 200 A, 277/480V EACH 847004 LIGHTING CONTROL AND DISTRIBUTION ENCLOSURE (120/240; 100 AMP) EACH 847006 LIGHTING CONTROL CABINET – 100 A EACH 847007 LIGHTING CONTROL CABINET – 200 A, 240/480V EACH LIGHTING CONTROL CABINETS SECTION 847
533 847008 LIGHTING CONTROL CABINET – 60 A, WITH SERVICE DISCONNECT EACH LUMINAIRE SECTION 850
534 SECTION 850 — LUMINAIRE
850.1Description.
This work consists of providing and installing LED light fixtures (luminaires) on poles (not inclusive in this item) with wattage, lamp type, and distribution type or removing luminaires.
850.2Materials.
Provide a complete fixture with a heavy duty, cast aluminum housing, door with extruded aluminum heat sink, toolless entry, hinged removable power tray door for easy maintenance, and fastening hardware that is stainless steel or zinc plated steel. The fixture shall meet ANSI 136.31
3.0G vibration requirements. Fixture shall have a two bolt slip fitter system for mounting on a 1
1/4-inch to 2 3/8 -inch mounting arm connection. A grey powder coat finish shall be applied to the fixture unless otherwise shown on the plans, or as directed by the engineer. Provide electrical materials in accordance with the NEC of the NFPA, and all local and state laws and ordinances governing such installations.
glass lens or acrylic or polycarbonate resin clear globe.
produces an audible click when locked.
sealed and filtered optical assemblies. LED module with robust, heat -dissipating housing and durable electrical connections.
LED drivers, surge protection, luminaire disconnect, and terminal block.
breakable glass finish, removable only by using a screwdriver.
excessive porosity, with all seams welded.