PORTABLE CHANGEABLE MESSAGE SIGN SECTION 803
430 SECTION 803 — PORTABLE CHANGEABLE MESSAGE SIGN
803.1Description.
This work consists of providing, placing, operating, relocating, and maintaining portable changeable message signs (PCMS).
803.2Materials.
Not applicable .
803.3Construction.
803.3.1 Equipment.
resistant materials and having the following:
discrete matrix.
unless placing the PCMS behind guardrail, barrier, or other means of positive protection. Place plastic drums in accordance with the DE MUTCD .
restricts the use of these facilities by pedestrians or cyclists. Provide a minimum 4 -foot buffer between the edge of the travel lane and the farthest extent of t he PCMS to allow bicycle traffic to pass without encroaching into the travel lane. 803.3.2 Operating Requirements.
accordance with the DE MUTCD . Align the PCMS toward oncoming traffic with the sighting device to provide alignment for maximum visibility.
contract or as directed by the engineer. Obtain approval from the engineer before placement of PORTABLE CHANGEABLE MESSAGE SIGN SECTION 803
431 the PCMS. Submit a PCMS Approval Form to the engineer for review and approval of messages and the PCMS location, if the contract does not contain approved messages or locations,
problem. Failure to correct the problem within the 24 -hours will result in no payment for the day the unit is not operating. Failure to correct the problem may also result in delay of work activities.
803.4Method of Measurement.
803.5Basis of Payment.
contract unit price per each day. Price and payment constitute full compensation for :
channelization around the PCMS .
ITEM DESCRIPTION UNIT 803001 PROVIDE AND MAINTAIN PORTABLE CHANGEABLE MESSAGE SIGN EA-DY PORTABLE FLIGHT ASSEMBLY SECTION 804
432 SECTION 804 — PORTABLE LIGHT ASSEMBLY
804.1Description.
This work consists of providing, placing, operating, relocating, and maintaining portable light assemblies.
804.2Materials.
Not applicable .
804.3Construction.
portable light assembly except when placing the portable light assembly behind guardrail, barrier, or other means of positive protection. Place plastic drums in a ccordance with the DE MUTCD . 804.3.1 Operational Requirements.
MUTCD. Position the portable light assembly so that it does not shine light directly at oncoming traffic. Extend the light assembly vertically to the unit’s fullest extent and direct the lights downwards toward the work area but not exceeding more than 60 -degrees measured off of the ground to prevent glare. Use channelization devices in accordance with the DE MUTCD to delineate the portable light assembly.
notification of an operational problem. Failure to correct the problem within the required timeframe will result in no payment for the day that the unit did not work.
related to the portable light assembly. Provide an ATSSA traffic control supervisor in accordance with Section 812. If the contract does not require an ATSSA traffic control supervisor, the contractor may use a superintendent or other designee as the on -site representative. When a portable light assembly used to illuminate a flagger station fails to work, remove the flagger from the roadway. Restore the roadwa y to normal operations until a working portable light assembly is provided and placed unless opening the roadway to normal operations presents a safety hazard to motorists.
804.4Method of Measurement.
calendar day.