820006 REINFORCED CONCRETE MASONRY SIGN FOUNDATION, W -18 EACH

DE · 2025 Standard SpecificationsBook pages 477477View official source ↗

BREAKAWAY I BEAM SIGNS SECTION 820

467 B. The Department will pay the quantity of breakaway I -beam sign posts at the contract unit price per linear foot. Price and payment constitute full compensation for:

1.Providing breakaway I -beam sign posts; and
2.providing and assembling breakaway coupling systems, bolt kits, hinge plates, nuts, bolts, and

cap screws and all other materials.

C.The Department will pay the quantity of breakaway coupling systems, bolt kits, and hinge plates at

the contract unit price per each. Price and payment constitute full compensation for:

1.Providing hinge plates, breakaway couplings, nuts, bolts, cap screws, and all other materials; and
2.assembling breakaway coupling systems.
D.The Department will pay the quantity of breakaway I -beam sign mounts installed or removed at

the contract unit price per each. Price and payment constitute full compensation for installation or removal of sign mounts.

E.The Department will pay the quantity of sign panels on breakaway I -beam sign supports installed

or removed at the contract unit price per square foot. Price and payment constitute full compensation for installation or removal of sign panels. ITEM DESCRIPTION UNIT 820001 REINFORCED CONCRETE MASONRY SIGN FOUNDATION, W -6 EACH 820002 REINFORCED CONCRETE MASONRY SIGN FOUNDATION, W -8 EACH 820003 REINFORCED CONCRETE MASONRY SIGN FOUNDATION, W -10 EACH 820004 REINFORCED CONCRETE MASONRY SIGN FOUNDATION, W -12 EACH 820005 REINFORCED CONCRETE MASONRY SIGN FOUNDATION, W -14 EACH 820006 REINFORCED CONCRETE MASONRY SIGN FOUNDATION, W -18 EACH 820007 SUPPLY OF BREAKAWAY I -BEAM SIGN POSTS, W -4 LF 820008 SUPPLY OF BREAKAWAY I -BEAM SIGN POSTS, W -6 LF 820009 SUPPLY OF BREAKAWAY I -BEAM SIGN POSTS, W -8 LF 820010 SUPPLY OF BREAKAWAY I -BEAM SIGN POSTS, W -10 LF 820011 SUPPLY OF BREAKAWAY I -BEAM SIGN POSTS, W -12 LF 820012 SUPPLY OF BREAKAWAY I -BEAM SIGN POSTS, W -14 LF 820013 SUPPLY OF BREAKAWAY I -BEAM SIGN POSTS, W -18 LF 820014 SUPPLY AND INSTALLATION OF BOLT KIT FOR BREAKAWAY COUPLING EACH 820015 SUPPLY AND INSTALLATION OF HINGE PLATE FOR BREAKAWAY COUPLING EACH 820016 SUPPLY AND INSTALLATION OF BREAKAWAY COUPLING SYSTEM EACH 820017 INSTALLATION OF BREAKAWAY I -BEAM SIGN POSTS EACH 820018 REMOVAL OF BREAKAWAY I -BEAM SIGN POSTS EACH 820019 INSTALL SIGN PANEL ON BREAKAWAY I -BEAM SIGN SUPPORT SF 820020 REMOVE SIGN PANEL ON BREAKAWAY I -BEAM SIGN SUPPORT SF